background image

XVT

600,

 

XVT

800,

 

XVT

1200,

 

XVT

1500

 

USER’S

 

MANUAL

 

UNINTERRUPTIBLE

 

POWER

 

SUPPLY

 

(UPS)

 

SAFETY

 

INSTRUCTIONS

 

ATTENTION:

 

To

 

safely

 

interact

 

with

 

and

 

enjoy

 

all

 

the

 

features

 

and

 

benefits

 

of

 

these

 

Xtreme

 

Power

 

Conversion

 

Uninterruptible

 

Power

 

Supplies

 

(UPS),

 

please

 

read

 

and

 

follow

 

all

 

installation

 

and

 

operation

 

instructions

 

completely.

 

These

 

UPS

 

are

 

designed

 

to

 

provide

 

power

 

protection

 

for

 

connected

 

electronic

 

equipment.

 

Please

 

read

 

this

 

manual

 

before

 

installing

 

the

 

XVT

Series

 

UPS

 

models

 

XVT

600,

 

XVT

800,

 

XVT

1200,

 

and

 

XVT

1500

 

as

 

it

 

provides

 

important

 

information

 

that

 

should

 

be

 

followed

 

during

 

installation

 

and

 

maintenance

 

of

 

the

 

UPS

 

and

 

batteries,

 

allowing

 

you

 

to

 

correctly

 

set

 

up

 

your

 

system

 

for

 

the

 

maximum

 

safety

 

and

 

performance.

 

Included

 

is

 

information

 

on

 

customer

 

support

 

and

 

factory

 

service,

 

if

 

it

 

is

 

required.

 

If

 

you

 

experience

 

a

 

problem

 

with

 

the

 

UPS,

 

please

 

refer

 

to

 

the

 

Troubleshooting

 

section

 

in

 

this

 

manual

 

to

 

correct

 

the

 

problem.

 

If

 

the

 

problem

 

is

 

not

 

corrected,

 

please

 

collect

 

information

 

so

 

that

 

the

 

Technical

 

Support

 

personnel

 

can

 

more

 

effectively

 

assist

 

you.

 

CAUTION:

 

Any

 

changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

the

 

manufacturer

 

of

 

this

 

device

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

 

FCC

 

Notice:

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

Digital

 

Device

 

pursuant

 

to

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

residential

 

installation.

 

This

 

equipment

 

generates

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

There

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

 

1.

 

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

 

2.

 

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

receiver.

 

3.

 

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.

 

4.

 

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

technician

 

for

 

help.

 

Any

 

special

 

accessories

 

needed

 

for

 

compliance

 

must

 

be

 

specified

 

in

 

the

 

instruction.

 

CAUTION:

 

A

 

shielded

type

 

power

 

cord

 

is

 

required

 

in

 

order

 

to

 

meet

 

FCC

 

emission

 

limits

 

and

 

to

 

prevent

 

interference

 

to

 

the

 

nearby

 

radio

 

or

 

TV

 

reception.

 

It

 

is

 

essential

 

that

 

only

 

the

 

supplied

 

power

 

cord

 

be

 

used.

 

Use

 

only

 

shielded

 

cables

 

to

 

connect

 

I/O

 

devices

 

to

 

this

 

equipment.

 

CAUTION:

 

Any

 

changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

the

 

manufacturer

 

of

 

this

 

device

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

 

 

[3]

 

Содержание XVT?1200

Страница 1: ...Xtreme Value Tower Series XVT User s Installation Manual Xtreme Power Conversion Corporation ...

Страница 2: ...TION 5 DETERMINING THE POWER REQUIREMENTS OF YOUR EQUIPMENT 7 HARDWARE INSTALLATION GUIDE 7 QUICKSTART SOFTWARE INSTALLATION GUIDE 9 REPLACING THE BATTERY 14 DEFINITIONS FOR LED INDICATORS 15 ALARMS 15 TROUBLESHOOTING 16 SPECIFICATIONS 17 SHIPPING LIST OBTAINING SERVICE 19 18 XTREME POWER CONVERSION XPC CORPORATION LIMITED WARRANTY 20 2 ...

Страница 3: ...its for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications There is no guarantee th...

Страница 4: ...tenance No user serviceable parts inside CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION UPS must be connected to an AC power outlet with fuse or circuit breaker protection Do not plug into an AC wall outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS DO NOT USE FOR MEDICAL OR LI...

Страница 5: ... Interactive Automatic Voltage Regulation AVR UPS technology Under normal AC power operation the input power flows through the AVR circuit regulating the incoming AC power to the output of the UPS and the load connected If the input power disappears the Inverter circuit is switched on to provide output from the batteries contained within the UPS 5 ...

Страница 6: ...ing a power failure Power Switch Can be used as a master on off switch for equipment connected to the battery powered outlets Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing power free of surges and spikes Circuit Breaker The circuit breaker that provides overload and fault protection USB Port protocol that provides communication be...

Страница 7: ...actors can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 85 of the UPS capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt however charging the battery for at least 4 hours is recommended to ensure that the batteries maximum charge capacity is achieved C...

Страница 8: ...he UPS on 6 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC wall outlet and there is acceptable AC voltage present the battery will automatically recharge Charging is controlled by firmware to rapidly charge units to 15VDC 600 800VA units and 29VDC 1200 1500VA units After this threshold is met the XVT places a float charge to maintain battery energy and the char...

Страница 9: ...ide the box 2 Insert one end of the USB Cable into the UPS and the other into a USB port on your computer 3 Insert the CD into your computers CD drive 4 When the software interface requests a serial number locate and input the serial number from the CD software jacket 5 Follow the software setup prompts 6 Quickstart Software Installation Guide 9 ...

Страница 10: ...VT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Input user name company name and serial number into the software interface Note the serial number is on the CD software jacket Choose installation location and click Next 10 ...

Страница 11: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Choose software language and click Next Software will install automatically 11 ...

Страница 12: ... XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Choose Will you run Powermanager II right now and click Finish After the UPS switches on please choose the System Setting tab from the drop down box 12 ...

Страница 13: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Click Local UPS and choose USB click OK The UPS is now connected and in normal operation 13 ...

Страница 14: ...tem voltage is only 12VDC and 24VDC the battery can present a high risk of short circuit current and electrical shock The short circuit current capability of the battery is sufficient to burn wire or tools very rapidly producing molten metal Observe these precautions when replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 Do not lay to...

Страница 15: ... Power OFF OFF FLASH On Battery ON Charge ON Overheat Low Battery Overload Protection Short Circuit Note means any situation ALARMS Alarm Indication Unit Status Buzzer every 5 sec DC start Buzzer every 1 sec Self test 2 buzzer every 1 sec Low battery 4 beep every 2 4 sec Overload 3 buzzer every 1 sec Overheat Input is off long beep power off after 5 sec Short circuit 15 ...

Страница 16: ...least 4 hours The battery is defective Contact Xtreme Power Conversion about replacement of batteries The UPS will not turn on The on off switch is designed to prevent damage by rapidly turning it off and on Turn the UPS off Wait 10 sec then turn the UPS on The UPS is not plugged into an AC wall outlet Connect the UPS to an 110 120V 60Hz AC wall outlet The battery is defective Contact Xtreme Power...

Страница 17: ...l load half load 3 min full load 6 min 50 load Charge Current 1 5A Max PHYSICAL Dimensions W x D x H inches W x D x H inches W x D x H inches W x D x H inches Product Dimensions 3 7 x 14 6 x 6 2 3 7 x 14 6 x 6 2 4 9 x 16 9 x 8 7 4 9 x 16 9 x 8 7 Shipping Dimensions 6 1 x 16 2 x 10 2 6 1 x 16 2 x 10 2 7 5 x 18 9 x 12 8 7 5 x 18 9 x 12 8 Product Weight 15 3 lbs 16 8 lbs 27 6 lbs 31 3 lbs Shipping We...

Страница 18: ...Mode Green LED on Orange LED on Red LED off no beep Charging Battery Orange LED on Battery Mode Green LED and Orange LED off Red LED flash buzzer slow beep Battery Low Green LED and Orange LED off Red LED on buzzer fast beep SHIPPING LIST 1 1 UPS 2 1 User s and Installation Manual 3 1 Intelligent monitoring software 4 1 USB computer port cable 18 ...

Страница 19: ...nician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer availa...

Страница 20: ... a the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s operating...

Страница 21: ...XVT 600 XVT 800 XVT 1200 XVT 1500 USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS 21 ...

Отзывы: