background image

NXRT

1000,

 

NXRT

1500,

 

NXRT

2000,

 

NXRT

3000

 

USER’S

 

MANUALUNINTERRUPTIBLE

 

POWER

 

SUPPLY

 

(UPS)

 

Please

 

handle

 

the

 

UPS

 

and

 

associated

 

equipment

 

with

 

extreme

 

caution

 

since

 

a

 

high

 

amount

 

of

 

energy

 

is

 

contained

 

in

 

the

 

batteries.

 

Always

 

keep

 

the

 

unit

 

in

 

an

 

upright

 

position

 

as

 

marked

 

on

 

the

 

packaging,

 

and

 

never

 

drop

 

the

 

unit.

 

Please

 

adhere

 

to

 

the

 

following

 

instructions

 

if

 

the

 

UPS

 

is

 

not

 

installed

 

immediately:

 

 

Store

 

the

 

equipment

 

as

 

is

 

in

 

its

 

original

 

packing

 

and

 

shipping

 

carton.

 

 

Do

 

not

 

store

 

in

 

temperatures

 

outside

 

the

 

range

 

of

 ‐

15°C

 

to

 

+25°C

 

 

Ensure

 

that

 

the

 

equipment

 

is

 

fully

 

protected

 

from

 

wet

 

or

 

damp

 

areas

 

and

 

from

 

moist

 

air.

 

In

 

order

 

to

 

maintain

 

the

 

batteries,

 

the

 

UPS

 

should

 

be

 

recharged

 

every

 

6

 

months

 

for

 

at

 

least

 

8

 

hours.

 

If

 

flammable

 

substances

 

such

 

as

 

gases

 

or

 

fumes

 

are

 

present,

 

or

 

if

 

the

 

room

 

is

 

airtight,

 

a

 

hazardous

 

situation

 

may

 

exist

 

in

 

which

 

no

 

electrical

 

equipment

 

should

 

be

 

operated.

 

The

 

instructions

 

in

 

this

 

manual

 

explain

 

how

 

to

 

install

 

the

 

UPS

 

safely.

 

Not

 

acknowledging

 

such

 

electrical

 

hazards

 

may

 

be

 

fatal

 

 

keep

 

this

 

manual

 

for

 

future

 

reference.

 

WARNING!

  

It

 

is

 

strongly

 

recommended

 

that

 

the

 

UPS

 

cabinet

 

not

 

be

 

opened

 

as

 

components

 

have

 

very

 

high

 

voltage

 

and

 

touching

 

those

 

components

 

may

 

be

 

fatal.

 

Only

 

a

 

qualified

 

technician

 

or

 

authorized

 

agent

 

may

 

service

 

the

 

unit.

 

The

 

UPS

 

unit’s

 

output

 

receptacles

 

carry

 

live

 

voltage

 

even

 

when

 

not

 

connected

 

to

 

an

 

input

 

voltage

 

source.

 

The

 

UPS

 

has

 

its

 

own

 

internal

 

energy

 

source.

 

Environment

 

Ensure

 

that

 

all

 

environmental

 

concerns

 

and

 

requirements

 

are

 

met

 

according

 

to

 

specifications

 

listed

 

in

 

this

 

document,

 

otherwise

 

the

 

safety

 

of

 

installation

 

personnel

 

cannot

 

be

 

guaranteed,

 

and

 

the

 

unit

 

may

 

malfunction.

 

Ensure

 

that

 

you

 

remember

 

the

 

following

 

when

 

locating

 

the

 

UPS

 

system

 

and

 

battery

 

options:

 

 

Avoid

 

extremes

 

of

 

temperature

 

and

 

humidity.

 

Maximum

 

battery

 

life

 

can

 

be

 

attained

 

with

 

a

 

recommended

 

temperature

 

range

 

of

 

+15°C

 

to

 

+25°C.

 

 

Provide

 

protection

 

for

 

the

 

equipment

 

from

 

moisture.

 

 

Space

 

and

 

ventilation

 

requirements

 

must

 

be

 

met.

 

Ensure

 

there

 

is

 

100mm

 

behind

 

and

 

50mm

 

on

 

the

 

sides

 

of

 

the

 

UPS

 

for

 

proper

 

ventilation.

 

 

Ensure

 

that

 

the

 

front

 

of

 

the

 

UPS

 

remains

 

clear

 

for

 

user

 

operation.

 

 

[13]

 

Содержание NXRT?1000

Страница 1: ...Network Xtreme Rack Tower Series NXRT User s Installation Manual Xtreme Power Conversion Corporation ...

Страница 2: ...you for selecting this uninterruptible power supply UPS It provides you with protection for connected equipment Please read this manual before installing the NXRT Series UPS models NXRT 1000 NXRT 1500 NXRT 2000 and NXRT 3000 as it provides important information that should be followed during installation and maintenance of the UPS and batteries allowing you to correctly set up your system for the ...

Страница 3: ...ing preventive measures Place the receiving antenna in a separate location or orientation Ensure a greater distance is achieved between the receiver and the equipment Ensure that your equipment is connected to an outlet on a separate circuit than the receiver Contact a technician experienced with radio and TV or a dealer for further assistance ICES 003 This Class B Interference Causing Equipment m...

Страница 4: ... may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on batteries Remove watches rings or other metal objects Use tools with insulated handles To reduce the risk of electric shock disconnect the UPS f...

Страница 5: ...ersonnel Before conducting any maintenance repair or shipment first ensure that everything is turned off completely and disconnected For additional safety instructions please use the Safety Manual as a reference Special Symbols The following symbols used on the UPS warn you of precautions RISK OF ELECTRIC SHOCK Please observe the warning that a risk of electric shock is present CAUTION REFER TO OP...

Страница 6: ... company accidents and radio transmission motors air conditioners and vending machines Protection of sensitive electrical equipment is vital to protect against power outages low or high voltage conditions slow voltage fluctuations frequency variations differential and common mode noise transients etc To prevent power line problems from reaching critical systems causing damage to software hardware ...

Страница 7: ...onal options are available for the solution Planning a UPS system the following should be taken into consideration The total demand of the protected system shall dictate the output power rating VA Allow a margin for future expansion or calculation inaccuracies from measured power requirements Backup time required will indicate the battery size needed If the load is less than the UPS nominal power ...

Страница 8: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS 8 ...

Страница 9: ... three LED s on the front control panel These LED s allow the user to quickly understand if any action is needed Red LED If this LED is illuminated it indicates a fault and the UPS will have no output Faults that would indicate this alarm condition include Overload Inverter fault BUS fault Over temperature fault 9 ...

Страница 10: ...escriptions There are four lines of information in the LCD display Each line provides specific information related to the unit status and or operation Line information will be described from top to bottom with the top being line one Line One Provides data in to numeric sections with the data corresponding to the applicable category in line one and two Line Two Allows the user to identify which var...

Страница 11: ...ecial intelligent network card can be compatible with popular software and hardware found on the web and in operating systems It can support operating systems such as HP Open View IBM Netview SUN Netmanager etc This enables the UPS to provide instant UPS and power information over the network Please contact your reseller for additional details Notes The UPS can be monitored through the RS232 inter...

Страница 12: ...may occur and cause the UPS to shut down and trip the circuit breaker 3 If the power requirements of your equipment are listed in values other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The equation below only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any given time Users should expect...

Страница 13: ...ot acknowledging such electrical hazards may be fatal keep this manual for future reference WARNING It is strongly recommended that the UPS cabinet not be opened as components have very high voltage and touching those components may be fatal Only a qualified technician or authorized agent may service the unit The UPS unit s output receptacles carry live voltage even when not connected to an input ...

Страница 14: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS Installation Standard brackets 14 ...

Страница 15: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS 19 Cabinet Ear Installation 15 ...

Страница 16: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS Vertical Installation Steps 16 ...

Страница 17: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS Wall mounted Installation Steps 17 ...

Страница 18: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS 19 Rack mount using 5 in 1 bracket 18 ...

Страница 19: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS RACK MOUNT INSTALLATION STEPS UPS Rail Installation Instructions to 19 Cabinet 1 2 3 19 ...

Страница 20: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS 4 5 20 ...

Страница 21: ...NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS 6 7 Note Any external Battery Packs must be installed next to or under the UPS Please refer to Appendix A Battery Pack User Guide for more information when installing these 21 ...

Страница 22: ...P from the EBP to an input AC utility source per specifications Connect a second battery pack to the first EBP in the same fashion if more than one is to be installed Refer to Appendix A Battery Pack User Manual for more details 2 Connect SNMP card option Remove the two screws securing the SNMP cover plate on the rear of the UPS and slide the SNMP NetAgentII card into the slot Secure the card into...

Страница 23: ... appear in the system tray of the desktop near the system clock Double click this icon to enlarge the program window Connect the RS232 cable included in the UPS packaging to the Computer and UPS Communication should start momentarily If it does not click on Settings up on the UPSilon toolbar then select a different Comport until communication is established Click on Manual in the UPSILON toolbar f...

Страница 24: ...e to be performed exactly as instructed in this manual The greatest care possible must be taken for any of these operations and any change thereof may prove very hazardous to the operator On Off Button Function Button Inquiry Button Turning Off the UPS when connected to an AC source Press and hold the ON OFF button for more than 3 seconds to turn off the UPS This means the internal inverter has be...

Страница 25: ...ger display information This indicates the UPS has no output Self Test Operation Please refer to the three operating buttons on the front panel of the UPS Confirm the UPS is in Utility Mode Press and hold the Function button for a minimum of two seconds The self test will last for 10 seconds during this time the LED s will be lit in a sequential repeating fashion Audible Alarm silence in DC Mode o...

Страница 26: ... batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION Although the battery system voltage is only 12VDC and 24VDC the battery can present a high risk of short circuit current and electrical shock The short circuit current capability of the battery is sufficient to burn wire or tools very rapidly producing molten metal Observe these precautions when replacing the batt...

Страница 27: ...000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS Slide the plastic cover to the right Remover the M5x10 screws on the right side Remove plastic front cover Locate the battery tray on the right front side of the UPS 27 ...

Страница 28: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS Remove 4 M4x6 screws marked with letter A Remove the battery tray from the UPS 28 ...

Страница 29: ...ility that circuit breaker on UPS has tripped Reset circuit breaker Insufficient battery run time Once every 4 seconds in DC mode On batt displayed on LCD 1 If batteries are undercharged let UPS charge batteries at least 12 hours 2 After charging if runtime is still insufficient replace with new batteries 3 Reduce output load to lengthen runtime UPS will not start after pressing the On Off button ...

Страница 30: ...RUPTIBLE POWER SUPPLY UPS LCD FAULT CODES BYP MODE LINE MODE BAT MODE BAT TEST MODE BUS FAULT 62 05 25 01 21 40 41 INV FAULT 61 63 04 24 42 OVERHEAT 33 06 08 43 OP SHORT 16 02 44 OVERLOAD 03 09 45 FAN FAULT 36 28 38 46 CHARGE FAULT 07 07 BAT OVER 11 11 11 11 30 ...

Страница 31: ... 60 Hz auto sensing THD full load Linear 5 non Linear 10 Wave Form Sine wave zero transfer time Load Power Factor 0 7 Efficiency AC DC AC 90 Auto Restart Yes Start on Battery Yes Rated Current 8 3 A 12 5 A 16 6 A 25 A Overload Capacity 110 150 for 30 sec 150 for 200 msec Crest Factor 3 1 at full load BATTERY Battery Type UPS 3 12V 9 AH 36V 4 12V 7 2 AH 48V 8 12V 7 2AH 96V Backup Time 7 11 min inte...

Страница 32: ... 20P L5 30P Receptacles 6 NEMA 5 15R 1 NEMA L5 20R 4 NEMA 5 20R 1 NEMA L5 30R 4 NEMA 5 20R Communication Interface RS 232 or SNMP optional card Included in box UPSILON CD horizontal brackets 5 1 brackets manual 6ft DB9 cable ENVIRONMENT Operating 0 40ºC 32 104ºF Temperature Audible Noise 50dba at one meter Altitude 6000 ft 1830 m above sea level WARRANTY Warranty Three years electronics One year b...

Страница 33: ...Type EBP 2 strings of 3 12V 9 AH 36V 2 strings of 4 12V 7 2 AH 48V 2 strings of 8 12V 7 2 AH 96V Recharge Time 4 hours to 90 6 hours to 90 PHYSICAL Dimensions W x D x H inches Unit Dimensions 17 3 x 17 7 x 3 4 17 3 x 25 6 x 3 4 17 3 x 21 7 x 5 2 Shipping Dimensions 22 3 x 23 5 x 9 2 22 3 x 31 4 x 9 2 22 3 x 27 4 x 11 0 Unit Weight 58 4 lbs 75 0 lbs 113 6 lbs Shipping Weight 69 5 lbs 86 0 lbs 125 7...

Страница 34: ...0 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS SHIPPING LIST 1 1 UPS 2 1 User s and Installation Manual 3 1 6 ft RS232 cable 4 1 UPSILON CD monitoring software 5 2 sets of 5 in 1 mounting brackets 6 1 set of horizontal mounting brackets 34 ...

Страница 35: ...nician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer availa...

Страница 36: ...d if a the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s opera...

Страница 37: ...MIN VA WATTS UPS 1 EPB 2 EPB 3 EBP 4 EBP 5 EBP NXRT 1000 500 350 23 85 178 268 333 456 1000 700 10 42 79 121 170 226 NXRT 1500 750 525 15 108 214 336 447 639 1500 1050 7 43 84 132 187 250 NXRT 2000 1000 700 28 170 333 521 737 985 2000 1400 14 68 130 202 284 378 NXRT 3000 1500 1050 19 105 204 318 448 599 3000 2100 8 42 81 126 178 237 Note for estimated run times using more than 5 EBP s contact Xtre...

Страница 38: ...BP3 is for NXRT 2000 3000 CONNECTING THE INCORRECT BATTERY PACK TO THE UPS MAY RESULT IN DAMAGE TO THE UPS AND OR BATTERY PACK WILL VOID THE WARRANTY All EBP s have a different DC voltage configuration intended only for the UPS s listed above PLEASE DO NOT MIX EBP s AND MAKE SURE YOU ONLY CONNECT THE EBP TO LIKE EBP s OR UPS INDICATED ABOVE DC VOLTAGES ARE MARKED ON BOTH THE UPS AND THE EBP MAKE S...

Страница 39: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS Extended Battery Pack Configuration 39 ...

Страница 40: ...NXRT 1000 NXRT 1500 NXRT 2000 NXRT 3000 USER S MANUALUNINTERRUPTIBLE POWER SUPPLY UPS 40 ...

Страница 41: ...m can be connected to multiple extended battery packs to increase the runtime when connected to the UPS supporting the load Most UPS Systems are limited to one or two external battery packs because the UPS is responsible for the recharging and does not have the recharge capacity to handle the additional batteries to a full recharge The NXRT UPS System overcomes this limitation by equipping each ex...

Страница 42: ... use a cable shipped with each EBP to daisy chain together additional EBP s to the first EBP being connected to the UPS in the appropriately labeled connector or for connecting the first EBP to the UPS 3 The AC input cord is for connecting AC utility to operate the Charger contained in each EBP 42 ...

Страница 43: ...ack Installation CAUTION Extended Battery Pack EBP Installation should be performed by qualified service personnel 1 Verify that the DC circuit breaker on the rear panel of the EBP is in the OFF position 2 Turn the UPS OFF and disconnect the UPS Input Cord from the AC wall outlet 3 Remove the EBP connector cover from the UPS rear panel 4 Connect the external DC battery cable from the EBP to the ap...

Страница 44: ...rge time It is recommended that every third EBP be connected to incoming AC utility to properly charge the batteries in a complete system Leaving too many chargers connected may cause an over charge situation which could damage the batteries 2 Which LED s are supposed to be lit on the front of each EBP When an EBP is connected to an AC input source and the unit is charging a GREEN LED on the front...

Страница 45: ...5 Why don t the LED s on each EBP connected to an AC input source turn ON and OFF at the same time The charger on each EBP functions independently from the others One EBP charger may be charging while another one might be at 100 and the charger turned off This is normal operation of the EBP ...

Отзывы: