15
assembly
NOTICE
REGARDING FIRST IGNITION OF HEATER. The first time you light the
heater, it should be done OUTDOORS. This allows the oils, etc. used in
manufacturing the heater to burn off outside.
Temperature Limit Control:
This heater is equipped with a Temperature
Limit Control designed to turn the heater off should the internal
temperature rise to an unsafe level. If this device activates and turns your
heater off, it may require service. Once the temperature falls below the
reset temperature, you will be able to start your heater.
Electrical System Protection:
This heater’s electrical system is
protected by a fuse that protects it and other electrical components from
damage. Fuse is located inside of an in-line “FUSE BARREL”. If your
heater fails to operate, check this fuse first and replace as needed. Refer
to Specification Chart in this manual.
Flame-out sensor:
Utilizes a photocell to monitor the flame in burn
chamber during normal operation. It will cause the heater to shut off
should the burner flame extinguish.
FUElING yOUR HEATER
Never fill the heater fuel tank in the living space, fill the tank outdoors. Do
not overfill your heater and be sure heater is leveled.
WARNING
• NEVER REFILL FUEL TANK WHEN HEATER IS OPERATING OR
STILL HOT.
ClEARANCES
Minimum clearances to outlet is 8 feet. Top, rear and sides minimum of 4
ft.