A1. MCS-2160 HyperTerminal Command – system chassis
When you cascade numerous
MCS-2160
, the number of total chassis cascaded will be shown as the
figure above on Total chassis number. In this example of the figure above, we cascaded 2
MCS-2160
together which is
Chassis ID 00
and
01
, the number than is shown as
Total chassis number 02
.
Note: The system is able to cascade up to 10 MCS-2160.
For upgrading your XC module cards’ firmware, please follow the steps below:
1. Type
sys show chassis
command, select the correct Chassis ID number and number order of the
XC module cards.
2. Download and install the
Tftpd32
software from internet.
3. Let the BIN file (firmware update file) inside a folder of your PC, and open this file by open the folder
with
Tftpd32
.
4. Set the Server Interface of
Tftpd32
as 192.168.1.17.
5. On the Hyper Terminal screen, type in “
sys update [firmware/fant] [remote file] [host ip]
” and click
enter
. Press
Y
to proceed and start upgrading firmware, or press
N
to cancel.
6. MCS-2160 will reboot when finishing upgrading the firmware.