![Xtrails ADPRO PRO-18 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/xtrails/adpro-pro-18/adpro-pro-18_planning-and-commissioning-manual_3766489036.webp)
28
Doc. 20780_03
Planning and Commissioning Manual
ADPRO Passive-Infrared (PIR) PRO Series by Xtralis
7
Operating Modes
7.1
Selectable Operating Modes
The detector can work in two operating modes:
Hardware
mode
Software
mode
The devices of all models are provided with the following features.
7.1.1
Modes
7.1.1.1 Hardware Mode
In hardware mode the detector can be configured and operated by means of DIP switches
located on the connector board of the detector.
By default, the detector operates in hardware mode and the DIP switches are pre-set as
follows:
Default Settings of
DIP Switches
DIP Switch
Status
Function
1
ON
Sensitivity
adjustment
2
OFF
3
ON
ATD
(Volumetric Models
only)
4 ON
Pulse
count
(PRO-45D(H) only)
4
OFF
Directional detection
5
OFF
Test
6
ON
Anti-tamper
(PRO-51, PRO-85(H),
PRO-100(H), PRO-
250H only)
7 ON
Mounting
height
8
OFF
No
function
NOTE!
More setting options are available in software mode.
7.1.1.2 Software Mode
In software mode, the detector can be configured and operated using the ADPRO®
Windows® PRO software.
Adjustable Functions only in Software Mode
The following adjustments are only available in software mode:
The following adjustments are only available in software mode:
Individual sensitivity adjustment (20% - 140% or 50%-150%, see individual detector
specification)
Individual pulse count for volume models (0-10 pulses)
Bi-directional
detection
for the PRO-45D(H) models
Individual anti-tamper alarm output (transistor and/or relay)
Activation/deactivation of left/ right channels for PRO-45D(H) models