![XTline XT121701 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/xtline/xt121701/xt121701_user-manual_3729723031.webp)
Clean-up and storage
When finished using the pressure cleaner, follow these steps to shut down the unit
:
-
Turn the pressure cleaner to the off position
-
Turn off the water supply
-
Before disconnecting high-pressure hose connection, point the gun in a safe direction and
discharge the high-pressure water.
-
Disconnect garden hose from the pressure cleaner
-
Remove quick coupler fitting from garden hose and attach to the nipple portion of the fitting
instaled on the pressure cleaner for storage.
-
Remove excess water from the pump by tipping the unit on both sides to drain any
remaining water from inlet and outlet fittings.
-
Remove water intake filter and flush with waster to remove dirt or debris. Return filter once
cleaned.
-
Drain detergent reservoir and flush with running water
-
Wipe away any remaining water on all parts and fittings
-
Engage the gun safety lock
-
Store the pressure cleaner parts, and accesories in an area with a temperature above 0° C
Winterizing and long-term storage
Follow all of the above shut-down procedures, adding the following steps:
- After disconnecting the water supply, and before disconnecting the high-pressure hose, turn
the pressure cleaner on for 2-3 seconds, until any remaining water in the pump exits. Turn unit
off immediately.
Continued use of the pressure cleaner without water supply attached will cause severe damage
to the unit!
- Always store the pressure cleaner, parts, and accesories in an arrea with a temperature 0° C
Maintenance
This pressure cleaner is supplied with a closed lubrication system, so no addiction of oil is
needed.
Check all hoses and accesories for damage prior to use.
Check the inlet filter periodically for deposits. Clean this filter regularly for maximum
perfomance.
WHEN THE SWITCH IS IN THE "I" POSITION THE MACHINE WILL NOT START
PROBABLE CAUSE
Electrical socket is faulty
Voltage is inadequate
Power cord is not plugged in
SOLUTION
Check plug, socket, fuses
Check whether the voltage is adequate
Plug in power cord
PROBABLE CAUSE
Water inlel filter is clogged
Pump is drawing air
Suction valves are clogged/worn
Diameter of garden hose too small
Waler supply is restricted
lnsufficient water supply
SOLUTION
Remove and clean filter
Tighten connections/bleed syslem
Clean or replace valves
Replace with ¾ inch garden hose
Check hose for kinks or leaks Fully open
water source
PROBABLE CAUSE
Excessive air in waterline and pu
m
p
SOLUTION
Turn unit and water supply off/
Bleed system/Hold trigger down
PROBABLE CAUSE
lntake ls blocked
Valves cire worn, dirty, or clogged
Filler is dirty
THE MOTOR STOPS RUNNING WHILE IN USE
PROBABLE CAUSE
Net voltage lower !han suggested
SOLUT10N
Check the intake valves
Check. clean or replace valves
Check, clean. or replace filter
SOLUTION
Check whether the voltage is adequate