5.4.1.4.4 TRANSMISSION Mode Menu
The Transmission mode screen only apprears in the STU-R. Please use remote logon to access
STU-R and then enter DSL menu to set up transmission mode. When transmission mode screen
appears, Annex A and Annex B is available to select. key in “1” to select Annex A and “2” to select
Annex B. Press Enter to submit your setting and press “ESC” to quit this screen. Press “M/m” to
back to main menu.
5.4.1.5 Set Rate Menu
The data rate for network interface is set at the STU-C (Central Site) only. After configuration, the
SHDSL system will use the line rate, which has been requested by user. User can select the
desired rate and data location in relation to an E1 frame by using the function keys located above
the current map. Whenever an asterisk appears under a number, the associated time slot/64K
channel is enabled and contains data to be transmitted between the two SHDSL units. During
64