background image

 

IR SPEED DOME 

 

PROTOCOL 

PELCO-D/P 

COMM 

2400.N.8.1 

DOME ID  

 

 001 

MODULE 
VERSION 

V1.2 

PAN 

INIT 

TILT 

INIT 

 

POWER ON 

 

 

IR SPEED DOME 

 

PROTOCOL 

PELCO-D/P 

COMM 

2400.N.8.1 

DOME ID  

 

 001 

MODULE 
VERSION 

V1.2 

PAN 

OVER 

TILT 

OVER 

 

POWER ON 

 

 

IR SPEED DOME 

 

PROTOCOL 

PELCO-D/P 

COMM 

2400.N.8.1 

DOME ID  

 

 001 

MODULE 

XXX 

VERSION 

V1.2 

PAN 

OVER 

TILT 

OVER 

 

POWER ON 

 

 

3. Instruction

 

 

3.1 Power On Action

 

 

 
 

 
 

When initializing the system, the operation as left figure will run 
in 2 seconds. 

 

When  restoring  out-of-factory  settings,  please  wait  patiently. 
The operation as left figure will run in 1 minute. 

 

This  left  figure  means  initializing  the  pan/tilt  motor  of  speed 
dome camera. 

 

 

 
 
 

 
 
 

 
 
 
 
 

 
 
 

The initialization of pan/tilt motor completes. It is initializing the 
camera and detecting the module of camera. 

 

 
 

 
 

 
 
 
 

 

XXX is the specific model of camera module which is displayed 
after camera finishes detection. 

 

Power on self testing completes. 

 

 
 
 

 
 
 

 
 
 

 

3.2 Basic Function 

Dome Running

 

Control joystick or up, down, left and right key in the keyboard. 

 

Zoom

 

Содержание SDOMEOIR6-CM10

Страница 1: ...SDOMEOIR6 CM10 SDOMEOIR6W SD2121 User manual ...

Страница 2: ...g flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to different persons The exclamation point within an equilateral triangle is intended to alert the user the presence of important operating and maintenance ...

Страница 3: ... or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera 5 All electrical connections to the dome should be made in strict accordance with the attached labels and wiring instructions in this manual Failure to do so may damage the dome beyond repair and void the warranty 6 For outdoor installatio...

Страница 4: ...damaged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 11 Indoor dome is for indoor use only and not suitable for outdoor or high humidity locations Do not use this product under circumstances exceeding specified temperature and humidity ratings 12 Avoid ...

Страница 5: ...10 4 OSD Menu 11 4 1 System 12 4 2 Dome Function 12 4 2 1 Preset 12 4 2 2 Scan 13 4 2 3 Guard Tour 13 4 2 4 Pattern 14 4 2 5 Privacy Zone 14 4 2 6 Other 15 4 2 7 Alarm 15 4 3 Camera 16 4 3 1 CAM ADV 16 4 3 2 CAM AE 16 4 4 IR 17 4 5 Display 17 4 6 Time 17 4 7 Language 18 4 8 Reset 18 Appendix Ⅰ Anti lightning Anti surges 19 Appendix Ⅱ Clean Transparent Cover 19 Appendix Ⅲ Common Knowledge on RS 485...

Страница 6: ...me user selectable Pattern Scan 4 pcs Pattern Scan Record max 15 minutes max 512 commands Park Time 1 60mins available PWR on Action Memory Pattern Tour 360 scan A B scan Preset 1 8 None Park Action Pattern Tour 360 scan A B scan Preset 1 8 None Communication Protocol Pelco D Pelco P Communication RS485 Bus Baud Rate 1200 2400 4800 9600bps Soft ID 1 255 Privacy Mask Support according to zoom modul...

Страница 7: ... group can be edited independently Optional IP module built in provision Built in high density RTC clock supports time management function Optional alarm 4 alarm inputs and 2 alarm outputs Park action If users don t operate the dome in set time it will automatically run preset guard group trace memory group pan scan etc Memory of operation before power off Built in fan and heater can control the t...

Страница 8: ...n scan the camera turning to up down left and right and zooming in or out can be saved This function remembers and imitates a process of operator s operation This dome camera has 4 path patterns Each path can record 512 different instructions or the longest 15mins path operation Opening any one of the paths can remember automatically the present running trace and scan cyclically according to the r...

Страница 9: ...speed will become faster 360 Scan Dome 360 clockwise continuously scans the display scene at set speed in horizontal direction under the condition that pitch angle remains the same In the scanning status operator can move the joystick to exit from scanning Preset After the dome camera keeps arbitrary PTZ location it will automatically move to the defined position when preset is called Guard Tour S...

Страница 10: ...function or parameter or check the related information through the OSD Return to PTZ Function Return dome s pan and tilt and camera zoom value to the control device 2 Installation 2 1 Product Dimension 2 2 Bracket Dimension ...

Страница 11: ...onnection Connection of RS485 Before connecting please turn off the power and read carefully the instructions of all connected devices Please use the standard power we supply and don t lengthen the power cable arbitrarily Fig 24 ...

Страница 12: ...the system the operation as left figure will run in 2 seconds When restoring out of factory settings please wait patiently The operation as left figure will run in 1 minute This left figure means initializing the pan tilt motor of speed dome camera The initialization of pan tilt motor completes It is initializing the camera and detecting the module of camera XXX is the specific model of camera mod...

Страница 13: ...n clear number enter Remark Some preset points are used tentatively for special functions 3 3 Special Function The follow presets are predefined as special function please shot preset No enter to enable those functions PREST FUNCTION PRESET FUNCTION 33 Pan scan180 º 86 BLC on 34 Reset 87 BLC off 75 Trace memory 1 88 Freeze on 76 Trace memory 2 89 Freeze off 77 Trace memory 3 91 Limited Points Scan...

Страница 14: ...e option select the item or confirm Left Return to main menu or cancel Zoom Display x XXX XXX is the present zoom of camera Time Display XXXX year XX month XX day XX hour XX minute XX second Angle Display XXX XX pan XXX XX tilt IR Display means the IR display status is on means the IR is on Remark means the cursor selecting some option means editing the content of some options ...

Страница 15: ...11 4 OSD Menu ...

Страница 16: ... upgrading COMM SET DEVICE ID It is only and used to distinct from the ID of other domes CHECK ID Distinguishing several domes with same ID and altering target ID soft protocol and baud rate need to enter check ID in line with the device ID otherwise altering can t be completed TARGET ID Target ID can be changed and edited on line It will be effective immediately after changed Dial the address num...

Страница 17: ... be set alone the dwell time and tour speed GUARD TOUR NO It has 1 4 groups settable CALL GUARD TOUR Call the guard tour ID edited successfully GUARD TOUR GUARD TOUR ID 01 POINT 01 TIME 05 SPEED ID The tour sequence of guard tour group Its range 64 is 1 16 02 02 05 64 POINT The preset of guard tour Its range is 01 64 03 03 05 64 settable 04 04 05 64 05 05 05 64 TIME The default time of all points ...

Страница 18: ...ET MASK PRESET 1 SAVE PRESET 2 BACK MASK NO Select the mask number It depends on the module supported SET MASK For detailed steps please refer to the Example of Setting Mask 1 MASK ON and OFF are selectable Example of Setting Mask 1 1 Move the cursor to MASK NO which is be selected by pressing the right key of direction 2 Press the up and down keys in the keyboard to edit the mask number as 1 whic...

Страница 19: ... If continuing withholding the joystick when beyond the maximum angle in tilt it flips horizontally 180 and 0 in tilt So vertical 180 whole continuous monitoring comes true 4 2 7 Alarm DOME PRESET SCAN GUARD TOUR PATTERN PRIVACY ZONE OTHER ALARM EXIT ALARM ALARM IN OFF ALARM OUT NC PATROL TIME 05S ALARM 1 PRESET 01 ALARM 2 PRESET 02 ALARM 3 PRESET 03 ALARM 4 PRESET 04 EXIT ALARM IN Alarm input has...

Страница 20: ... 000 255 BLUE GAIN It can only be adjusted under the condition that the WB mode is manual And its range is 000 255 SHARPNESS Its adjustable range is 0 15 grade BLC It has ON and OFF selectable WDR It has ON and OFF selectable 4 3 2 CAM AE CAM AE AE MODE AUTO IRIS MODE AUTO IRIS TIME AUTO SHUTTER AUTO GAIN AUTO ICR DAY EXIT IRIS TIME Set the speed of iris varying SHUTTER Set the camera shutter Ther...

Страница 21: ... switch from near illumination to far illumination Zoom value options depend on the module 01 10 12 Default setting is 05 Eg when the zoom value is set to 06 the IR LEDs will auto switch from near illumination to far illumination after the zoom value reaches to 6X or more than 6X AMBIENT LIGHT This function is system data and can t be changed It updates automatically for the ambient light in the r...

Страница 22: ... TIME Set the system time ...

Страница 23: ...ess left key to return to the previous page Remark When the schedule is set there can not be overlap part in periods of time The system will respond at priority to the first triggered schedule only after which is completed it will respond other schedules Please make sure there is only one schedule at some certain period System will return to preset 1 after completing schedule 4 7 Language LANGUAGE...

Страница 24: ...h power lightning protection equipment and lightning rod must be taken Lightning protection and grounding of outdoor devices and lines must take the lightning protection requirements of buildings into consideration and comply with the related national standards and industry standards System must be equipotential grounding Grounding device must meet dual requirements of anti interference and electr...

Страница 25: ...d device 2 Mode of Connection and Terminal Resistance 2 1 Industry standard of RS485 bus requires that connection mode in a daisy chain should be used between the devices with 120Ω terminal resistances connected at the both ends As shown in fig 26 and fig 27 is simplified connection but the distance of part D shall not beyond 7 meters Fig 26 Fig 27 2 2 120Ω terminal resistance is connected as show...

Страница 26: ...s per the instruction manual Noise self testing after Mechanical obstruction Verify and correct it Camera module is not installed correct Correct Low power Change the correct power supply Image is not stable Low power Check the power supply or make sure the power input is AC 24V Video cable is improperly connected Verify the connection of the video cable Image is blurring Camera is on manual focus...

Отзывы: