Input the master code.
(Default:   [                  ] +[#] )

- All settings will restore to their 

default value.

- When power on or activate 

the reset all setting item,the 

keypad checking will carry out,

during this time,the key 

illumination will blink and the

touching operation is forbidden,

after finish checking,the key 

illumination will stop blinking 

and sent out a long sound of beep

- The master code is allowed 1~12

digits,the same code cannot be set

for both the user code and the

master code,it is recommended

that you modify the default master

code.

- The unlock time can be set on  

both monitor and door station,

and the valid value is the number 

you set last time. 

(white)

The color of key indicator

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+

Beep+

Beep+

Beep+

Inputting of code (ex.: 10)

range:00 or 10~99

Inputting of code (ex.: 09)

range:01~99

   3.Setting the key 

      illumination time

   4.Setting the 

      unlock time

   2.Setting the master code

(Default 1234)

(Default 10s)

(Default 1s)

Inputting of new master code 

(ex.:  4321)(1~12 digits)

Input the setting code. 

Inputting of code 

Input the setting code. 

   1.Reset all settings

00+#

1234+#

4321+#

01+#

10+#

09+#

Input the setting code. 

02+#

Input the setting code. 

03+#

- If the key illumination time is set 

to 00,the key illumination will light

up all the time when power on.

- If the key illumination time is set to 

10~99,the key illumination will light 

up for 10~99 seconds.At this mode,

the key illumination lights off in 

standby mode, touching any digital 

key can illuminate,but this is the

invalid digital.

(yellow)

The color of key indicator

(yellow)

The color of key indicator

(yellow)

The color of key indicator

(yellow)

The color of key indicator

The color of key indicator

(green    white)

The color of key indicator

The color of key indicator

The color of key indicator

(green    white)

(green    white)

(green    white)

When the  “     cancel”  key is pressed, the  indicator will show its standby color, the buzzer beeps, and the system 
exits the setting mode.

When there isn’t any operation in 10s, the  indicator will show its standby color, the buzzer beeps, and the system 

   exits the setting mode.

Beep, Beep+

 *

(The color 

 of standby)

The color of 

key indicator

When setting failure, the color of key indicator will turn red , the buzzer beeps.

Содержание DPC-D248-K

Страница 1: ...DPC D248 K 2 wired door station 1 2 3 4 5 6 7 8 9 0 User manual...

Страница 2: ...arts and Functions 1 2 Mounting 1 3 Terminal Descriptions 2 4 System Wiring and Connections 3 5 Functions Setting Up 9 6 Power Supply Instructions 17 7 Precaustions 17 8 Specifications 17 9 Cables Req...

Страница 3: ...late Call Button Microphone 93 mm 28 mm 182 mm 1 4 5 6 9 8 0 7 2 3 Night Light 2 Mounting 1 2 4 3 Drill holes in the wall to match the size of screws and attach the rainy cover to the wall Attach the...

Страница 4: ...per To select the lock type Main Connect Port To connect the bus line and the electronic locks BUS Connect to the bus line no polarity PL External lock power input connect to the power positive power...

Страница 5: ...al Power Note 1 Electronic lock of Power on to unlock type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit B...

Страница 6: ...VER Updated Home Installer setup Caliber TouchScreen Code Number 0010 Remove all remote control 0011 Add remote control 8000 Set as master unit 0 8001 Set as slaver unit 1 8002 Set as slaver unit 2 80...

Страница 7: ...tions Connection 85 260VAC D2A PS5 monitors 1 Camera 2 Camera 3 Camera 4 Camera DBC4 A B C D BUS L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S Device Address 3 Device Address 2 Device Address 1...

Страница 8: ...T Wiring Mode Multi Monitors Connection monitor monitor monitor 85 260AC D2A PS5 Code 0 DIP 6 off Code 14 DIP 6 off Code 15 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 4 5 6 9 8 0 7 2 3 De...

Страница 9: ...A B C D IN OUT 85 260AC D2A PS5 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code 15 DIP 6 on Code 13 DIP 6 on Code 3 DIP 6 on Code 1 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6...

Страница 10: ...4 5 6 ON 1 2 3 4 5 6 ON HI DBC4 A B C D IN OUT Code 0 DIP 6 on CALL UNLOCK TALK MON IN USE Code 3 DIP 6 on Code 2 DIP 6 on Code 1 DIP 6 on CALL UNLOCK TALK MON IN USE CALL UNLOCK TALK MON IN USE CALL...

Страница 11: ...ade input the following setting codes to continue the setting operation Press to exit the setting mode The example is set as cancel button and as confirm button please refer to function setting for de...

Страница 12: ...Disable Enable 08 10 Interference resistant grade settings Valid keys 0 5 2 09 11 MIC Adjustment Valid keys 0 9 7 10 12 SPK Adjustment Valid keys 0 9 7 11 13 Display Scene Valid keys 0 2 0 12 14 Nigh...

Страница 13: ...t 1234 Default 10s Default 1s Inputting of new master code ex 4321 1 12 digits Input the setting code Inputting of code Input the setting code 1 Reset all settings 00 1234 4321 01 10 09 Input the sett...

Страница 14: ...e passwords except the master code Restore the master code to default value 1 2 3 4 When the item is set to 0 press the button to cancel the input and press the button to confirm the input When the it...

Страница 15: ...een white Beep Beep Beep 11 IMC volume adjust setting Input the setting code 10 Inputting of code ex 5 range 0 9 5 Default 7 yellow The color of key indicator The color of key indicator green white Be...

Страница 16: ...The color of key indicator The color of key indicator green white yellow The color of key indicator The color of key indicator green white Beep Beep Beep 15 Device address setting Input the setting c...

Страница 17: ...the same time The temporary code can not be set the same as the master code and user code The user code group1 is used to release the first lock and the user code group2 is used to release the second...

Страница 18: ...Default 1 villa Inputting of code ex 1 range 0 a partment 1 villa 0 Inputting of code ex 1 range Valid keys 0 9 When the work mode is villa the call address 00 or 16 When the work mode is a partment t...

Страница 19: ...supply 12Vdc 300mA Internal Power Number of relay circuits 2 the second lock need external device to support Mounting Surface mounting Working temperature 10 C 45 C Dimension 182 H 93 W 44 D mm Pleas...

Страница 20: ...quantity 20 Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 When Monitor quantity 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1 5 mm2 70 50 3...

Отзывы: