XTBA “Product Name” Page 8 of 8
Product #01512 July 2014 © XTBA 1986 – 2015
POWER SUPPLY
The mains input to the transformers is via a 2A a/s fuse and the transformers
may be switched to 120 volt operation via the internal PCB mounted selection
switches. A spare fuse is provided in the input connector block on the rack unit.
19” RACK MOUNTING
The XTBA Smart Splitter 10i/RDM View is provided with a pair of ‘ears’ for fitting
into a 19” rack frame. The ears are fitted to the unit by removing the two screws
on either side at the front of the unit. The stick on rubber feet (used when the
unit is free standing) will need to be removed from the underside of the unit.
Technical Specifications 19” Rack Front or Rear connectors
Dimensions
230/270mm inc. front handles x 430mm x 82mm 2U
Weight
4.5 Kg
Power
100/130V or 190/250V AC Internal switch
Nominal 2A 240V AC
Data
DMX512 1986/1990 + DMX RDM
Pin Configuration
Pin 1 Common, Pin 2 minus data, Pin 3 plus data.
Pins 4 and 5 are not connected on any connectors.
CE Declaration of conformity
XTBA declares that the following equipment meets the requirements of the
EMC Directive 89/366/EEC. WEE/FC2753ZS
Unit 2 The Old Curatage
The Street Caston NR17 1DD
44 (0) 208 882 0100
email [email protected] www.xtba.co.uk