DS8000 Operator’s Manual 

 

ta

x

 

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS    

 

 

CAUTION: RISK OF ELECTRIC SHOCK. 

DO NOT OPEN 

 

 

 
 

 

 
 
 

WARNING:  Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective 
earthing connection. 
 
WARNING:  To prevent injury, this apparatus must be securely attached to the rack in accordance with the 
installation instructions. 
 
1.  Read these instructions. 
 
2.  Keep these instructions. 
 
3.  Heed all warnings. 
 
4.  Follow all instructions. 
 
5.  Do not use this apparatus near water. 
 
6.  Clean only with a dry cloth. 
 
7.  Do not block any ventilation openings, install in 
accordance with the manufacturer’s instructions. 
 
8.  Do not install near any heat sources, such as 
radiators, heat registers, stoves or other apparatus 
(including amplifiers) that produce heat. 
 
9.  Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding-type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If 
the provided plug does not fi t into your outlet, consult 
an electrician for replacement of the obsolete outlet.  
 
10.  Protect the power cord from being walked on or 
pinched particularly at plugs, convenience 
receptacles and the point where they exit from the 
apparatus. 
 
11.  Only use attachments/accessories specified by the 
manufacturer. 
 
 

 

12.  Use only with the cart, tripod, bracket or table 
specified by the manufacturer, or sold with the 
apparatus. When a cart is used, use caution when 
moving the cart/apparatus combination to avoid injury 
from a tip over. 
 
13.  Unplug this apparatus during lightning storms or 
when unused for a long period of time. 
 
14.  Refer all servicing to qualified service personnel. 
Servicing is required when the

 

apparatus has been 

damaged in any way, such as if the power-supply cord or 
plug is damaged, liquid has been spilled or objects have 
fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, 
or has been dropped. 
 
15.  Do not expose this equipment to dripping or 
splashing and ensure that no objects filled with liquids, 
such as vases, are placed on the equipment. 
 
16.  To completely disconnect this equipment from the 
AC mains, disconnect the power cord from the mains 
circuit breaker. 
 
17.  This unit is fitted with a 3-wire power cord. For 
safety reasons, THE EARTH LEAD SHOULD NOT BE 
DISCONNECTED IN ANY CIRCUMSTANCE. 
 
 

 

The lightning flash with arrowhead 
symbol within an equilateral triangle is 
intended to alert the user to the presence 
if uninsulated “dangerous voltage” within 
the product’s enclosure that may be of 
sufficient magnitude to constitute a risk 
of electric shock to persons. 

The exclamation point within an 
equilateral triangle is intended to alert 
the user of important operating and 
maintenance (servicing) instructions in 
the literature accompanying the 
appliance. 

Содержание DS8000

Страница 1: ......

Страница 2: ...DS8000 Operator s Manual Page 2 ta x...

Страница 3: ...DS80 CONNECTING YOUR DS80 CONNECTING YOUR DS80 CONNECTING YOUR DS8000 00 00 00 10 10 10 10 Inputs 10 Outputs 10 External Supply 10 OPERATING YOUR DS800 OPERATING YOUR DS800 OPERATING YOUR DS800 OPERAT...

Страница 4: ...UR DS8000 S8000 S8000 S8000 23 23 23 23 Maintenance 23 Warranty 23 Factory fit options 24 PERFORMANCE OF YOUR PERFORMANCE OF YOUR PERFORMANCE OF YOUR PERFORMANCE OF YOUR DS8000 DS8000 DS8000 DS8000 25...

Страница 5: ...t the following products Kind of equipment Audio Splitter Commodity Code 8518408990 Type Designation DS8000 is manufactured in accordance with EMC Directive 2004 108 EC in compliance with the followin...

Страница 6: ...ex Cooper the DS8000 offers many novel facilities including a dual redundant power supply simple Outside Broadcast one to many split switching and 48V safe functions to prevent tampering Subtle panel...

Страница 7: ...the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart...

Страница 8: ...li l appareil cela est galement valable pour une ventuelle rallonge lectrique 11 Utilisez exclusivement des accessoires et des appareils suppl mentaires recommand s par le fabricant 12 Utilisez exclus...

Страница 9: ...Electrical Considerations The unit is fitted with a universal power supply that will operate from 100V to 240V AC mains Make sure power outlets conform to the power requirements listed on the back of...

Страница 10: ...he chassis mains earth on the FOH and MON outputs only If ground loops mains hum are encountered try using the ground lift switches on the rear panel If problems persist consult your dealer supplier D...

Страница 11: ...solo bus connected between units as a stray solo left on can waste hours looking for the odd signal you can hear in your headphones if it is on a different but connected unit Note that if an O B Spli...

Страница 12: ...on this feature are given on page 10 5 Solo bus input output sockets The solo bus is externally accessible via these sockets allowing multiple units to share the bus When units are daisy chained using...

Страница 13: ...O 48V SENSE 48V SENSE 5V MON FOH INPUT 5V 48V SAFE SWITCHES REAR PANEL FRONT PANEL CONTROL SENSE MON CONTROL SENSE FOH CONTROL 12 0 PIN 1 LIFT SWITCHES REAR PANEL LIFT M ONITOR PIN 1 S LIFT FRONT OF H...

Страница 14: ...OUTPUT CHANNELS 5 OUTPUT CHANNELS 6 OUTPUT CHANNELS 7 OUTPUT CHANNELS 8 Input to output paths with O B Split features enabled The FOH and MON output sockets also have sensing circuitry to detect the...

Страница 15: ...input on the rear panel As the monitoring point for the solo signal is before the O B Split switching enabling a Solo on a channel whilst in O B Split mode will still feed the local channel s input s...

Страница 16: ...the grounding use for a shield is derived from the remote device to retain galvanic isolation and prevent possible hum loops or potential differences across various grounds causing other problems Howe...

Страница 17: ...the inputs have their pin connections grounded but this can be lifted on an individual input basis by removing the zero Ohm links on the rear panel PCB The diagram below shows the rear of the board w...

Страница 18: ...outputs using its own internal clock with adjustable sample rate 48k 96k 192k or be synchronised via an external clock on the BNC connector Default setting as shipped is Internal wordclock so BNC is...

Страница 19: ...ted sample rates so 48 96 192 this is known as permissive mode and is explained below Permissive Clock Mode When sync is set to external the DS8000 will only lock to an external wordclock if it falls...

Страница 20: ...as show below fs Sample rate LED operation This tri colour LED will illuminate to show the sample rate being used by the AES outputs Red 48kHz Yellow 96kHz Green 192kHz The table below summarises how...

Страница 21: ...es that the device at the other end of the cable has a mains ground reference If it does not then the link shown below on the digital option PCB can be fitted Default setting as shipped is ground lift...

Страница 22: ...7 5 B3 Chs 5 6 B3 Chs 5 6 B3 Chs 5 6 B3 Chs 5 6 15 3 16 B4 Chs 7 8 B4 Chs 7 8 B4 Chs 7 8 B4 Chs 7 8 1 14 2 The DS8000 s digital outputs utilise industry standard drivers and circuitry to ensure that t...

Страница 23: ...oubts about carrying out maintenance please refer to a service engineer or contact your local dealer Warranty Your DS8000 is guaranteed for a period of five 5 years from the date of purchase We hope t...

Страница 24: ...dual outputs Note that this option drops the gain on these outputs by 10dB so they run with the gain control set to 0dB at 10dB through the unit Convert transformer balanced front outputs to electroni...

Страница 25: ...150R Isolation kV 2 5kV System Parameter Units Electronic standard Transformer option Frequency Response 22Hz 22kHz dB 0 0 5dB 0 1 5dB Distortion 1kHz 0dB Gain 4dBu Output 0 01 0 01 Equivalent Input N...

Страница 26: ...leading to a poor signal to noise ratio The task of signal distribution can at it most basic level be as simple as a Y Split cable which feeds two inputs from a single output perhaps to drive two amp...

Страница 27: ...this phenomenon creates a filter that will decrease the high frequency content present leading to dull audio Adding equalisation at the mixing desk to compensate will also accentuate the noise content...

Страница 28: ...noise issues but the following problems still remain with an additional one also being introduced As there is still no active circuitry the signals are still being distributed at low levels which are...

Страница 29: ...the associated decrease in signal to noise ratio caused by the extra gain The output drivers for each feed are also lower impedance so reducing the effects of cable loading the capacitative effect re...

Отзывы: