www.xsens.com
14
Document MT0513P.C
© Xsens Technologies B.V.
User Manual MTi 1-series DK
Figure 8: Physical location of components
4.2.2 Physical dimensions
Figure 9: The outer dimensions of the MTi DEV Board. PCB spacers are placed
4.2.3 Electrical specifications
The Development Board has the same communication protocol as the MTi 1-series module. The table below shows
the electrical specifications for the Development Board.
Table 4. System specifications Development Board
Min
Typ
Max
Unit
Comments
VDD
3.3
5.5
V
VDDIO
1.6
5.5
V
SyncIn
V
IH
0.75 * VDDIO
V
V
IL
0.25 * VDDIO
V