Use according to destination                                            

 

This  instrument  is  designed  exclusively  for  electrochemical  measurements  both  in  the  laboratory  and 
directly in the field. 

 

Pay attention to the technical specifications shown in the INSTRUMENT FEATURES / TECHNICAL DATA table; 
any other use is to be considered unauthorized.

 

This instrument has left the factory in perfect technical and safety conditions.

 

The  regular  functionality  of  the  device  and  the  operator  safety  are  guaranteed  only  if  all  the  normal 
laboratory safety standards are respected and if all the specific safety measures described in this manual 
are observed.

 

 

 

Basic requirements for safe use

 

The  regular  functionality  of  the  device  and  the  operator  safety  are  guaranteed  only  if  all  the  following 
indications are respected:

 

 

The instrument can be used in accordance with the specifications mentioned above only.

 

 

The instrument must operate exclusively in the environmental conditions indicated in this manual.

 

 

The only part of the instrument that can be opened by the user is the battery compartment.

 

Any other operation have to be authorised by the manufacturer.

   

 

 

Unauthorised use

 

The instrument must not run, if:

 

 

It is visibly damaged (for example due to transportation).

 

 

it has been stored for a long period of time in adverse conditions (exposure to direct light, heat sources 
or  places  saturated  by  gas  or  vapours)  or  in  environments  with  conditions  different  from  those 
mentioned in this manual.

 

 

 

Device maintenance                                                          

If used correctly and in a suitable environment, the instrument does not require maintenance procedures.

 

It is recommended to occasionally clean the instrument case with a damp cloth and a mild detergent. This 
operation must be performed with the instrument off and by authorized personnel only.

 

The housing is in ABS/PC (acrylonitrile butadiene styrene /polycarbonate). This material is sensitive to some 
organic solvents, for example toluene, xylene and methyl ethyl ketone (MEK). 

 

If liquids get into the housing, they could damage the instrument. 

 

Do not open the instrument housing: it does not contain parts that can be maintained, repaired or replaced 
by the user. In case of problems with the instruments, contact your local distributor.

 

It is recommended to use original spare parts only. Contact your local distributor for information. The use 
of non-original spare parts can lead to malfunction or permanent damage to the instrument. Moreover, the 
use of spare parts not guaranteed by the supplier can be dangerous for the user himself.

 

 

 

Responsibility of instrument owner

 

The person who owns and uses the tool or authorizes its use by other people is the owner of the tool and 
is responsible for the safety of all users of the tool and third parties.

 

The owner of the instrument must inform users of the use of the same safely in their workplace and on the 
management of potential risk, also providing the required protective devices.

 

When using chemicals or solvents, follow the manufacturer’s safety data sheets. 

 

 
 
 
 
 

Содержание Temp70 PT100 vio

Страница 1: ...INSTRUCTIONS MANUAL Temp70 PT100...

Страница 2: ...1 UM Termometri Temp70 PT100 Vio ENG rev 0 05 04 2021...

Страница 3: ...es 6 Datasheet 6 Instrument description 7 Display 7 Keypad 7 LED 8 Setup 8 Supplied components 8 Start up 8 Switching On Off 8 Batteries replacement 8 Instrument transportation 9 Key Functions 9 Input...

Страница 4: ...100 Vio ENG rev 0 05 04 2021 Warranty 18 Warranty period and limitations 18 Disposal of electrical devices 18 XS Instruments Via della Meccanica n 25 41012 Carpi MO ITALY Tel 39059 653274 Fax 39059653...

Страница 5: ...ided ATTENTION for a dangerous situation with reduced risk which can cause material damaged data loss or minor or medium sized accidents if not avoided WARNING for important information about the prod...

Страница 6: ...rs or in environments with conditions different from those mentioned in this manual Device maintenance If used correctly and in a suitable environment the instrument does not require maintenance proce...

Страница 7: ...and automatic with integrated sensor Sleep mode Yes Auto switch off Yes after 20 minutes deactivable LED indication Yes Reading stability indicator Yes adjustable Low Med High Stability filter HOLD Ye...

Страница 8: ...ing function MAX MIN if active OK Setup Key to confirm the values and enter into the setup menu from the meausure mode Up directional Key Save data for scrolling through menus and parameters Press fas...

Страница 9: ...m by pressing the button The display initially activates all segments and then appears model and firmware of the instrument information about the calibration of the channel 1 and the channel 2 screen...

Страница 10: ...different views while the two probes are connected channel 1 channel 2 and both channels simultaneously Into the setup menus press to return to measure mode Short To scroll and modify the values of th...

Страница 11: ...ay FIXED Automatic Data Logger set INTERMITTENT Automatic Data Logger in operation Instrument connected to the DataLink software Device operation On the left side of the display through a string of di...

Страница 12: ...ibration data P7 4 Select resolution P7 5 Stability filter P7 6 Reset settings P8 0 LOG SETTINGS P8 1 Log type P8 2 Clear data P9 0 SETTINGS P9 1 Temperature unit P9 2 Date and time P9 3 Backlight mod...

Страница 13: ...resolution for the temperature reading 0 1 0 01 Factory Default settings Note changing the temperature resolution the temperature resolution for both channels will change too P7 5 Stability filter To...

Страница 14: ...uisition mode MANUAL The data is acquired only when the user presses the button HOURS MINUTES Set a frequency range of automatic data acquisition With the direction keys move from MANUAL to HOURS or M...

Страница 15: ...configuration menu In measure mode press button to access the SETUP menu Press the key or to move to SETTINGS menu P9 0 Press the key to access the menu Move with keys and to select the program to ac...

Страница 16: ...ly saving battery consumption Note To exit from the Sleep mode and return the display to normal brightness press ANY button Once the display brightness is activated the buttons reacquire their functio...

Страница 17: ...screen on the display a text string will flash MIN MAX REC 1 probe connected REC both probes connected Press the key once to check the maximum value reached up to that moment press it another time to...

Страница 18: ...h the key or and confirm with the key In the middle of the display the correct temperature is displayed while the partial value of the calibration is displayed below it The adjustment changes the enti...

Страница 19: ...acturer will repair or replace defective components This warranty is valid only and exclusively on the electronic parts of the device and does not apply if the product has been damaged used incorrectl...

Отзывы: