Remove the solenoid valve from the filler. Use the
release tool provided to disconnect the push-to-connect
fittings. You do not have to remove the tube from the
valve.
Slide off the clip from the top of the coil assembly.
Remove the coil assembly off the center shaft. Unscrew
the shaft from the stainless steel base. It is not necessary
to unscrew the tubing adaptors from the stainless steel
base.
Now rinse out all the openings inside and outside of the
solenoid
valve,
removing
any
particulates
and
stickiness that may have accumulated.
Reassemble and replace in the filler.
Note:
This maintenance is needed only when the filler
is not performing properly.
CO2 Purge Solenoid Valve Deep-Cleaning Instructions