Remove the solenoid valve from the filler. Use the
release tool provided to disconnect the push-to-connect
fittings.
Loosen the hex nut at the top of the coil assembly.
Unscrew the base from the coil assembly. Use a
screwdriver as needed. Remove the center shaft. Note
the O-ring. DO NOT LOSE THE O-RING! A pair of
pliers may be needed to grip the metal shaft to “crack”
open for unscrewing the shaft.
Now clean out all openings inside and outside of the
solenoid
valve,
removing
any
particulates
and
stickiness that may have accumulated.
Reassemble and replace in the filler.
Note:
This maintenance is needed only when the filler
is not performing properly.
The white plastic body is stamped #1 for output and
#2 for input. The valve may leak if
installed back-
wards.
Fluid Solenoid Valve Deep-Cleaning Instructions