www.xprgroup.com
5
PROGRAMMING FLOWCHART
Start
Enter “Master Code” OR “
000
” (if first time use)
1 small beep + 1 long beep + Yellow LED is ‘ON’
Validate by pressing (
B
)
Validation OK?
Validation OK?
Quit
programming
See:
Assign a User code
above
See:
Assign Output
above
See:
Output Timer
above
Proximity
Reader
Keypad
Reader
Enter new code
(1 to 8 digits)
Present Card/Tag
before the Reader*
Press
A
to validate
Press
B
(Yellow LED is ‘OFF’)
Assign a
User Code
Press (0)
+
Memory position from 01 to 99
Change
Master Code
Press (0)
+
Memory
position (00)
Delete Single
Code
Press (9)
+
Memory position
from (01 to 99)
Delete All Codes
Press (8)
+
(99)
Set Output Timer
Pulsed Mode (01 to 99 sec):
Relay (2A):
Press (1) + (from 01 to 99)
Transistor:
Pres (2) + (from 01 to 99)
OR
Latch Mode (ON/OFF):
Press (1) or (2) + (00)
Assign Output
Press (3)
+
Memory position from
(01 to 99)
+
Press (1) for Relay
OR
Press (2) for Transistor
OR
Press (12) for both
Multiple small beeps
+
Yellow Led blinks rapidly
NO
NO
NO
YES
YES
End
Notes
Memory Position for User Code is always 2 digits
*no need to validate with
A
YES
Assign Examples
Ex.1: To assign User Code “12345” at Memory Position “5” and Relay (2A) in Latch Mode assuming Master code = 000
Press
000B
+
0
+
05
+
12345
+
A
+
3
+
05
+
1
+
A
+
1
+
00
+
A
+
B
.
Ex.2: To assign User Code “6789” at Memory Position “6” and Transistor that activates for 5 seconds assuming Master code = 000
Press
000B
+
0
+
06
+
6789
+
A
+
3
+
06
+
2
+
A
+
2
+
05
+
A
+
B
.