background image

www.xprgroup.com

2

1 ABOUT THIS DOCUMENT

2 SAFETY

This operation and assembly manual describes the electronic cabinet lock . It is part of the product and PXP-CL-MF con-

tains important information that is necessary for proper operation and maintenance.

This operating and assembly manual is valid for all versions of PXP-CL-MF and is intended for technicians responsible for

assembling and disassembling, as well as for end customers.

Read this operating and assembly manual carefully for smooth and safe operation and follow the instructions given in it

before operating the cabinet lock.

Keep the operating and assembly manual in a safe place.

After the installation, hand over the manual to the end customer and make sure that the customer familiar with its use.

XPR does not assume any responsibility for disruptions or hazards such as non-access to injured personnel, malfunc-

tions, property damage or other damages resulting from non-compliance with this operating and assembly manual or 

incorrectly configured cabinet locks.

If there are still any doubts after reading this operating and assembly manual, please contact your respective dealer or 

XPR directly.

1.1 Warnings

2.1 Proper use

Warnings warn against hazards that may arise when using the cabinet locks. There are two levels of warnings that can

be identified based on the signal word.

Signal word Significance:

CAUTION - Indicates a hazard with a low risk that can lead to mild or moderate injury if not avoided.

ATTENTION - Indicates a hazard that results in property damage.

The electronic cabinet lock PXP-CL-MF is intended to be installed in cabinet doors and for opening the doors.

The cabinet lock can be installed in doors with a maximum thickness of 20 mm. The different versions of the locking 

lever enable it to be used in many commonly available cabinet doors.

PXP-CL-MF can be used only indoors.

2.2 Improper use

The PXP-CL-MF must not be used for locking up supplies required in case of emergencies (for example defibrillator,

emergency medication, fire extinguishers, etc.).

2.3 General safety instructions

Follow these basic safety instructions when using the cabinet lock:

Installation and battery replacement should only be done by qualified technicians according to the instructions in this

operating and assembly manual.

Do not use the cabinet lock in potentially explosive areas.

Do not make any kind of modifications to the cabinet lock, with the exception of those described in this operating and

assembly manual.

Do not apply paints or acids to the cabinet lock.

Do not heat the cabinet lock and battery beyond the specified storage temperature.

Use only original spare parts and accessories to prevent malfunctions and damages.

Содержание PXP-CL-MF

Страница 1: ...ories 7 4 Assembly 8 4 1 Assembly instructions 8 4 2 Assembly 8 5 Operation 9 5 1 Automatic wake up 9 5 2 Opening the door 9 5 3 Toggling the cabinet lock 10 5 4 Indications 10 6 Cleaning and maintena...

Страница 2: ...he cabinet locks There are two levels of warnings that can be identified based on the signal word Signal word Significance CAUTION Indicates a hazard with a low risk that can lead to mild or moderate...

Страница 3: ...issued The engagement is accompa nied by red flashing 5x and 5 short acoustic signals Phase 2 The battery needs to be changed If an authorized key is held in front of the cabinet lock the cabinet lock...

Страница 4: ...on 3 versions of the locking lever 1 Mounting nut Cabinetinet lock 2 Locking lever has to be ordered separately 3 Lock washer 4 Mounting nut locking lever 5 Operating lever 6 Mounting screw 7 Button f...

Страница 5: ...Operating temperature Storage temperature Door thickness Dimensions when installed Transponder Power supply Battery life Indoors Installation location up to 74 500 operations or 10 years 5 C to 55 C...

Страница 6: ...Radio Stick is required for firmware upgrade The USB desktop reader is used for read write operations with the cards If the RF key is presented in front of a component of the locking system then it i...

Страница 7: ...with the door open Ensure that the latches or seals fitted to the door do not hinder the proper operation of the PXP CL MF Ensure that the cabinet lock does not protrude and prevent the door from swin...

Страница 8: ...rotation of the operating lever is determined by the position of the small screw on the mounting thread Opening by turning the operating lever to the left Opening by turning the operating lever to th...

Страница 9: ...ww xprgroup com 9 Mount the cabinet lock using the mounting nut and mounting screw Secure the locking lever and lock washer with the mounting nut locking lever Check if the cabinet lock is functioning...

Страница 10: ...ont of the reading unit only after this Wake up the cabinet lock by pressing the button Hold the authorised key in front of the reading unit till the green LED starts glowing Open or close the cabinet...

Страница 11: ...e battery position 5 brief high audible signals red LEDs flash 5 times simultaneously then 5 seconds engagement delay green LEDs start flashing at the same time Start of service mode End of service mo...

Страница 12: ...ed battery and insert the new battery paying attention to the polarity Push the battery compartment into position until it locks into place When managing the locking system using the Key Manager softw...

Страница 13: ...ignals 5 long audible signals 6 brief audible signals 5 long audible signals 7 brief audible signals If the faults mentioned above occur repeatedly then please contact the concerned dealer The disasse...

Страница 14: ...ft 4 Go to Configuration card tab 5 Put the Initialization card on the USB Desktop Reader and click on Initialization Card Wait for confirmation message Initialization Card created 6 Hold the card in...

Страница 15: ...gain you need to issue initialization card To change any setting in the door lock you can use Configuration Card 1 Go to Hardware Configuration Doors Select the door make the necessary changes and cli...

Страница 16: ...n message Card created From than on the card can be used Note Card holder card can be any card that is Mifare Desfire or Mifare Classic should be enabled in Site settings 1 Go to Reports Create Collec...

Страница 17: ...7 To obtain of the events already downloaded go to Reports Event Report Select the period and click on Load Additional filtering can be done by time door event type card holder The reports can be expo...

Страница 18: ...com 18 This product herewith complies with requirements of EMC directive 2014 30 EU Radio Equipment Directive 2014 53 EU In addition it complies with RoHS2 directive EN50581 2012 and RoHS3 Directive...

Отзывы: