www.xprgroup.com

2

EN

V+

V-

+

-

5

5

7

6

ON

1

2

OFF

Connection example of 1 door

This product herewith complies with requirements of EMC directive 2014/30/EU.

In addition it complies with RoHS2 directive EN50581:2012

Run Led

Box Tamper

Led Comm

Net

Reader

Reader

Door contact

Electromagnetic Lock 12V/600mA max

Power supply 14,2VDC

Push button

Address 0

Address 1

See user manual

12V battery

- For doors equipped with 2 readers, one must be at address 0 and the other at address 1. If there is 

only 1 reader, then it is recommended to be put with address 0.

- LIYCY cable, twisted pair, up to 80m. (5)

If more than 80 m. are needed, then termination resistors(120 ohm) may be required at both ends of 

the RS485 line, while taking into consideration the lengths proposed on our web site.

- Alarm cable 2x0,22 (6)

- The cross section of the cable depends on the current needed by the lock (7)

Note: The elevators relay boards (WS4ꢀRBꢀ12) are connected on the same RS485 lines as the readers.

OFF

ON

1

Lan

Autonomous

2

Master

Slave

Dip Switch