Output Connection for AC Device - Fail Secure
Application & Wiring
Output Connection for DC Device - Fail Open
OPERATION
Backlight ON/OFF
MTT operates in Latch and Pulse mode.
The time is set by Dipswitch setting.
Note:
Set the operating time only before
switching on power to the MTT.
If the operating time is to be changed,
select a new time setting and then wait a
few seconds for the circuit to re-adjust
before switching back the power.
The table illustrates the dipswitch settings in different modes
Approvals and Safety standards
Immunity: Meets to EN50082-2 (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5 and EN61000-4-6)
Operation
Switch 1
Switch 2
DipSwitch
Latch Mode
ON
ON
10 Seconds
ON
OFF
5 Seconds
OFF
ON
3 Seconds
OFF
OFF
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS2 directive EN50581:2012