background image

- 12 -

CF35

 - Activated Carbon Filters are used to remove contaminants and impurities through the process 

of chemical absorption. The CF35 captures a wide variety of volatile organic compounds that includes 

smoke, food odors, fumes from paint and paint thinners, sewer odors and more. Carbon Filters can be 

reused if the adsorbed substances are removed. This process is known as 'regeneration'. Simply 

heating the spent carbon at a given temperature for an adequate length of time can regenerate activated 

carbon to the point where it can be reused. The CF35 fits the X-3500 model; it is placed inside the 

housing in front of the HEPA filter. Always make sure that the Air Scrubber is turned off when removing 

the carbon filter. Never use water to clean the CF35 filters. Use vacuum or clean cloth and lay it flat on 

a clean and dry surface. For best results, put the CF35 under the sun and leave it there for a couple of 

hours. The capacity of the carbon filter will vary widely depending on conditions, but it should be replaced 

when a decline of effectiveness is noted.

X-3500 Primary Filter Care

Содержание X-3300

Страница 1: ...Models X 3300 X 3500 AIR SCRUBBER OWNER S MANUAL...

Страница 2: ...ons 5 Parts List 6 7 4 Stage Filtration Systems 8 Maintenance 9 14 Cleaning of Washable Nylon Pre Filters 10 X 3300 Primary Filter Care 11 X 3500 Primary Filter Care 12 13 Filter Replacement 14 Troubl...

Страница 3: ...h capacity motor for spaces up to 1500 sq ft Enjoy breathing healthier with your XPOWER Professional Air Purification Equipment Features 4 stage air filtration system Low amp usage with high airflow c...

Страница 4: ...ility for examination and or repair 5 Air Scrubber is an automatically operated device To reduce the risk of injury disconnect from power supply before servicing 6 Do not run cord under carpet Do not...

Страница 5: ...fully place the Air Scrubber upright on a stable flat dry surface 3 Plug the electrical cord into the power outlet 4 The unit can be used in 2 different angle positions vertical and horizontal 5 Turn...

Страница 6: ...Filter Activated Carbon Filter Washable PETPurifying Filter Washable PETPurifying Filter WF35 16 x 16 x 1 4 HEPA35 16 x 16 x 1 4 HEPA Filter FILTER CLEAN CHANGE LIGHT STACKABLE SAFETY CERTIFICATIONS E...

Страница 7: ...let 3 Inlet Panel 4 Latch 5 16 x16 Nylon Mesh Filter 6 Activated Carbon Filter 7 1 4 Thick HEPA Filter 8 9 Front Housing 10 Pressure Switch 11 Fan 12 Motor 13 HEPA Filter Change Light 14 Speed Control...

Страница 8: ...5 6 1011 12 13 9 14 15 16 17...

Страница 9: ...16 Washable Inner Nylon Mesh Filter CF35 16 x 16 x 1 4 Activated Carbon Filter HEPA35 16 x 16 x 1 4 HEPA Filter 4 Stage Filtration Systems 1st Stage 2nd Stage 4th Stage 3rd Stage X 3300 X 3500 WF35 Do...

Страница 10: ...crubber and extend the life of primary filters Both the XPOWER X 3300 and X 3500 filtration system include easy to clean washable nylon pre filters that should be frequently maintained Monitor filters...

Страница 11: ...uter nylon mesh filters then rinse with water and lay flat on a clean and dry surface to dry completely before re installing The NFR12 and NFS16 filters are used for X 3300 and X 3500 air scubbers as...

Страница 12: ...t up when filters need attention Always make sure that the Air Scrubber is turned off before removing filters Cleaning X 3300 PET Purifying Filters WF35 1 Remove filters and lay them on a flat clean s...

Страница 13: ...r an adequate length of time can regenerate activated carbon to the point where it can be reused The CF35 fits the X 3500 model it is placed inside the housing in front of the HEPA filter Always make...

Страница 14: ...on respiratory problems The HEPA filter requires a simple maintenance routine which can be performed in a timely and cost effective manner To maximize HEPA filter life be sure to clean change the pre...

Страница 15: ...ys essential for these tasks If you ve used the air scrubber for mold remediation or in another environment with known contaminants you should also consider wearing gloves eye protection and coverall...

Страница 16: ...et Wiring failure Contact XPOWER for service repair Scraping noise from fan Obstruction at the intake or exhaust of fan Remove obstruction Fan broken Contact XPOWER for service repair Weak air flow Ob...

Страница 17: ...tenance or repair or failure to perform necessary maintenance or repair or if the use of this product is not in compliance with the instructions and speci cations for its use For Warranty service and...

Страница 18: ...ryers X 430TF w 430MDK 1 3 HP 3 8 Amps 2000 CFM X 800TF w 800MDK 3 4 HP 7 5 Amps 3200 CFM B 4 3 HP 10 Amps 150 CFM with vacuuming feature B 8 4 HP 12 Amps 150 CFM brushless DC motor with heater B 25 4...

Страница 19: ...XPOWER MANUFACTURE INC Address 220 Clary Ave San Gabriel CA 91776 Tel 626 285 3301 Fax 626 285 3302 Warranty Registration Company Name Contact Person Title State Province Zip Country for US customer...

Страница 20: ......

Страница 21: ...es up to 1500 sq ft Enjoy breathing healthier with your XPOWER Professional Air Purification Equipment Models X 3300 X 3500 Features 4 stage air filtration system Low amp usage with high airflow capac...

Страница 22: ...g 6 Do not run cord under carpet Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will no...

Страница 23: ...ed speed and make sure the unit operates normally 6 To reduce the risk of injury close supervision is necessary when the machine is used near children Do not allow children to play with or around the...

Страница 24: ...d Carbon Filter Washable PETPurifying Filter Washable PETPurifying Filter WF35 16 x 16 x 1 4 HEPA35 16 x 16 x 1 4 HEPA Filter FILTER CLEAN CHANGE LIGHT STACKABLE SAFETY CERTIFICATIONS ETL CETL 4 STAGE...

Страница 25: ...ve all debris from both the inner and outer nylon mesh filters then rinse with water and lay flat on a clean and dry surface to dry completely before re installing The NFR12 and NFS16 filters are used...

Страница 26: ...tration efficiency XPOWER Air Scrubbers include on board pressure sensors that automatically alert the Filter Change Clean Light when the filters need cleaning The filter may needs to be changed after...

Страница 27: ...of effectiveness is noted Precautionary Measure When Cleaning and Changing Filters An air scrubber captures particles that can be hazardous to human health During the process of changing filters decon...

Страница 28: ...sociated with indoor air pollution the filter is designed and implemented to trap even the tiniest contaminants approximately 99 97 of all particles measuring 0 3 microns that aren t usually captured...

Страница 29: ...directly or indirectly to misuse abuse disassembly alteration corrosive chemicals improper voltage re ood negligence accident improperly or incorrectly performed maintenance or repair or failure to p...

Страница 30: ...ryers X 430TF w 430MDK 1 3 HP 3 8 Amps 2000 CFM X 800TF w 800MDK 3 4 HP 7 5 Amps 3200 CFM B 4 3 HP 10 Amps 150 CFM with vacuuming feature B 8 4 HP 12 Amps 150 CFM brushless DC motor with heater B 25 4...

Отзывы: