Fan Settings. 

 

SPEED SETTING 
The fans are factory set to low speed, but have two speed settings for different applications. Select either high or low speed 
by connecting the jumper between the centre and high or low speed pin on the jumper (see Figure E)  

 

DX150TS / DX150TR Only. 

 

To adjust the over-run period turn the control (T) clockwise to increase and anti-clockwise to decrease – see Figure D.

 

 
DX150HTS / DX150HTR Only – see figures D and E. 

 

The  pre-set  humidity  operation  is  factory  set  at  approximately  75%  Relative  Humidity  (RH),  but  can  be  adjusted 
between 65% and 85% RH by control H. 

 

The over-run timer is factory set at 15 minutes but can be adjusted from 30 seconds to 30 minutes by control T. 

 

Turn the controls clockwise to increase RH or time and anti-clockwise to decrease. 

 

Using the fan. 

DX150S / DX150R Only 

 

Operate the fan using the on/off switch (not supplied). Repeat to switch off. 

 

DX150PS / DX150PR Only 

 

Operate the fan by pulling and releasing the cord. Repeat to switch off. 

 

DX150TS / DX150TR Only 

 

Operate the fan using an on/off switch (not supplied). When the switch is turned off, the fan continues to operate for 
the set time delay. To adjust  the over-run period, turn the control “T” clockwise to increase and anti-clockwise to 
decrease – see Figure F. 

 

DX150HTS / DX150HTR Only. 

 

Automatic mode

 - The fan automatically adjusts to slow changes in natural humidity levels without operating the fan.  

If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will 
not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than 
5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable 
time delay. 

 

External operation

 - Use the external on/off switch. When the fan is switched off, the fan continues to operate for 

the adjustable time delay then goes into automatic mode.  

 

All Fans 

Re-fit the front cover/baffle assembly by hooking in the top first, and then swing the cover down to clip into place. 

 
 
 
 
 
 

 

 

 

Cleaning (recommended once a month). 

1.

 

Before cleaning, isolate the fan completely from the mains supply. 

2.

 

Remove the front cover/baffle assembly by depressing the latch on the underside of the cover 
and pulling off the front cover / baffle from the bottom. 

3.

 

To clean the front cover/baffle assembly, either wipe it with a damp, lint free cloth or wash it 
with warm soapy water. Thoroughly dry the front cover and refit. 

4.

 

Do not immerse the fan in water or other liquids to clean any other parts of the fan. 

5.

 

Do not use strong detergents, solvents or chemical cleaners 

6.

 

Allow fan to dry thoroughly before use. 

7.

 

Apart from cleaning, no other maintenance is required. 

 

 

Disposal 

This product should not be disposed of with household waste. 
Please recycle where facilities exist. 
Check with your local authority for recycling advice. 

Содержание Simply Silent DX150

Страница 1: ...on includes quick fit clamps Front grille fascia can be removed for easier cleaning Optional wall kit available separately Building Regulation Part F compliant Standard timer delay pullcord or humidistat versions Optimised impeller blade design minimises noise Flow straighteners guide air through duct Long life ball bearing motors suppress noise Provides near silent operation Just 15dBA in low spe...

Страница 2: ...vary Standard Operation Turns on and off with the main switch which it is wired to Timer Delay Operation Set at installation to run on after the main switch has been turned off to continue working for up to a maximum of 30 minutes Made in the UK For fixed wiring circuits protective fuse for the appliance must not exceed 5A Wiring Diagrams Standard Version Timer Version Simply Silent DX150 6 150mm ...

Страница 3: ...sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for the benefit of the user UK customers If you have any queries before or after installing this product call the Xpelair Technical Hotline 44 0 844 372 7766 Our engineers are there to help you during normal office hours Or you can f...

Страница 4: ...itch not supplied In automatic mode the built in timer automatically operates the fan for a pre set delay time from 30 seconds to 30 minutes once humidity drops below the pre set Relative Humidity RH value External operation When switched off using the external on off switch the fan continues to run for the preset delay from 30 seconds to 30 minutes Factory settings Timer 15 minutes RH 75 Overall ...

Страница 5: ...Back plate fixing positions Wall tube quickfix clamps Front Cover Removal A B C D Minimum 30 seconds Maximum 30 minutes Factory settings Timer 15 minutes RH 75 ...

Страница 6: ...Wiring and setting up E ...

Страница 7: ... internal doorway Near the source of steam or odours Not where ambient temperatures are likely to exceed 50 C If installed in a kitchen fans must not be mounted immediately above a cooker hob or eye level grill If installing in a room containing a fuel burning device which has a non balanced flue it is the installer s responsibility to ensure that there is enough replacement air to prevent fumes b...

Страница 8: ... holes in the back plate 5 Remove the back plate from the ducting 6 Drill screw holes in these positions if necessary and fit wall plugs and screws as required The fan may also be fixed to a wall tube using the clamping brackets See 9 below Mount the back plate 7 Feed the mains cable through the cable entry hole in the back plate to the terminals 8 Insert the fan tube of the back plate into the wa...

Страница 9: ...atural humidity levels without operating the fan If the humidity levels increase at a rate slower than 5 RH in 5 minutes up to the pre set humidity level the fan will not be triggered by humidity This is to prevent nuisance triggering of the fan If humidity levels increase quicker than 5 RH in 5 minutes the fan will operate When relative humidity drops the fan continues to operate for the adjustab...

Страница 10: ...ernational below United Kingdom Xpelair have a comprehensive range of services including Free technical advice help desk from Engineers on all aspects of ventilation Free design service quotations and site surveys Service and maintenance contracts to suit all requirements Please ask for details By telephone on Techline 44 0 844 372 7766 By fax on Techfax 44 0 844 372 7767 At the address below Head...

Отзывы: