For Australia Only –
DX150
S /
DX150
R /
DX150
PS /
DX150
PR
Connection to the supply can be made by a flexible 2-core cable complete with 3 pin plug for insertion into an approved 10A
GPO or directly wired through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.
For Australia Only –
DX150
TS /
DX150
TR /
DX150
HTS /
DX150
HTR
These models are permanently connected to the supply and operation is controlled by a remote switch. They should be directly
wired to the supply through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts.
Preparing the Fan for installation.
1.
Remove the front cover/baffle assembly by depressing the latch on the underside of the cover and pulling off the front
cover / baffle from the bottom (See Figure C).
Mark the position of the back-plate
2.
Hold the back-plate so that the level line marked on it is orientated horizontally.
3.
Carefully insert the fan tube into the wall duct.
4.
Mark on the wall the positions of the fixing holes in the back-plate.
5.
Remove the back plate from the ducting.
6.
Drill screw holes in these positions if necessary, and fit wall plugs and screws as required. The fan may also be fixed
to a wall tube using the clamping brackets. See 9 below.
Mount the back-plate.
7.
Feed the mains cable through the cable entry hole in the back plate to the terminals.
8.
Insert the fan tube of the back-plate into the wall duct/ceiling as before.
9.
Fasten the back-plate to the wall/ceiling using appropriate fasteners. See figure A.
10.
If using screws, do not over tighten. The fan may also be fixed to a wall tube using the clamping brackets. Tighten the
screws until the fan is firmly secured to the tube – see figure B.
Wire the electrical connections.
11.
Make sure the mains supply is isolated. Switch off the mains electrical supply and remove fuses.
12.
Feed the cable to the terminal block. Wire the fan as shown in Figure F using the diagram appropriate to the fan
model.
13.
Connect the cable from the isolating switch to the electrical supply wiring.
F
If working above ground floor level, safety precautions must be observed.
If installing in a ceiling, appropriate termination ancillaries are required. Follow
instructions provided.