7
(Continued)
5. Make all connections within the Isolating Switch.
WARNING: Do not make any connections to the Electrical Supply at this
stage.
For Australia only: These models are permanently connected to the supply and
operation is controlled by a remote switch. They should be directly wired to the
supply through an approved 10A wall mounted surface switch with at least 3mm
clearance between contracts.
Preparing the hole
If installing in a window, get a ready-cut pane to the dimensions given in Fig. 1.
If installing in a wall:
1. Make sure that the centre of the hole is located at least 205mm from the edges
of the wall.
2. Check there are no buried pipes of cables in the wall or obstructions on
the outside e.g. Electricity, Gas, Water.
3. Mark on the wall the centre of the hole and drill right through.
4. Draw a circle on this centre to suit the wall duct.
5. Cut the hole. Do not cut right through the wall.
(The recommended method is to drill a series of holes, close together, around the
edge of the cutting line and remove the brick between the holes with a chisel.
Warning: eye protection must be worn).
6. Go outside and cut a hole in the outer wall, repeating the process described
above.
7. Fit the ducting.
8. Make good the hole. Allow the Mortar to set before continuing the Fan
installation.
Separate the Fan from the Inner Clamp Plate
1. Remove the inner grill and back draught shutter by first removing the screw
from the underside of the grille then unclipping the bottom of the grille, the top of
the grille can then be released by unclipping the top corner. The shutter can then
be unclipped. NOTE: The top of the grille can only be released when the screw is
removed and the bottom of the grille has been released (Fig. 2).
2. Unscrew the four cross-headed screws and lift off the Fan (Fig. 3).
Mount the Fan in the hole (Fig. 4)
Xpelair recommended that the instructions of this section are carried out by two
people.
If working above Ground Floor level, appropriate safety precautions must be
observed.
If installing the fan in a window, fix the three rubber edge protectors (packed
separately) at equal distances around the lip of the Outer Clamp Plate.
1. Attach the Ladder Strips (packed separately) to the Outer Clamp Plate.
2. Hold the Outer Grille up to the outside of the wall or window so that the lip of
the Outer Clamp Plate protrudes into the hole.
3. Hold the Inner Clamp Plate to the inside of the wall or window and guide the
Ladder Strips from the Outer Clamp Plate through the slots in the Inner Clamp
Plate.
4. Insert the slotted screws (packed separately) into the pockets around the
ladder Strip slots.
5. Tighten the screws carefully to make a good seal.
Do not overtighten.
6. Trim the Ladder Strips back to the required length, if necessary remove any
sharp edges.
Refit the Fan to the Inner Clamp Plate
1. Fit the Fan Assembly onto the Inner Clamp Plate (Fig. 3).
2. Make sure that the Ladder Strips go inside the Fan Assembly so they will not
get caught in the blades.
3. Tighten up the four screws. Do not overtighten.
Wire the electrical connections
1. Remove the Fan Connector Plate carefully by unscrewing the two screws (Fig.
5). The Connector Assembly parts are contained loosely behind this plate.
2. Remove the two cable clamp screws (Fig. 8).
3. If required, feed the cable through the grommet (packed separately) in order to
fit to the cable entry of the Connector Plate.
j
If installing a GX9 with an on/off switch:
1. Wire the Fan Connector as shown in Fig. 6a.
2. Set the Fan Selector Switch to Position 1 for intake, Position 2 for extract or
Position 3 for "open shutter only" (Fig. 7).
j
If installing a GX9 with a controller:
1. Refer to the installation instructions for the controller.
2. If wiring to an existing controller, contact Xpelair Technical Services or in
export markets, the Xpelair distributor.
3. Set the Fan Selector Switch to Position 3 if using a controller providing variable
speed and/or direction. Otherwise, set the Fan Selector Switch to Position 1 for
intake, Position 2 for extract or Position 3 for "open shutter only" (Fig. 7).
j
If installing a GXC9 :
1. Wire the Fan Connector as shown in Fig. 6b.
T
Fitting the Cable Clamp
j
For the GX9:
For cable up to 8mm diameter, clamp the cable as shown in Fig. 8a.
For cable equal to or greater than 8mm and up to 11.5mm diameter, clamp the
cable shown in Fig. 8b.
For cable greater than 11.5mm diameter use the conduit entry provided.
j
For the GXC9:
For cable upto 6mm diameter, clamp the cable as shown in Fig. 8a.
For cable equal to or greater than 6mm and upto 10mm diameter, clamp the
cable as shown in Fig. 8b.
For cable greater than 10mm diameter use the conduit entry provided.
U
Fitting the Connector to the Fan
1. Ensure the cable is firmly retained by the clamp.
2. Assemble the Fan Connector by snapping the Cover over the
Connector (Fig. 9).
3. Plug the Fan Connector into the Fan Assembly.
4. Refit the Connector Plate.
5. Refit the Backdraft Shutter.
6. Refit the Inner Grille.
7. Switch off the mains electrical supply and remove fuses.
8. Connect the cable from the isolation switch to the electrical supply writing.
9. Replace the fuses, and switch on the mains electrical supply.
j
For fixed wiring circuits the protective fuse for the appliance must not
exceed 5A.
Q
Operating the Fan
GX9 (switch operated):
To switch on and off, use the switch on the wall or ceiling.
GX9 (controller operated):
Refer to the instructions for the controller.
j
The shutters are operated by a silent thermo-actuator which has a time delay
on opening (30-50 secs) and closing (3 mins).
GXC9 (cord operated):
To switch on, pull down the cord and then release it. Repeat to switch off.
M
Trickle Ventilation
j
Trickle Ventilation is equivalent to that provided by an air brick or similar
device.
1. Remove the inner grill and back draught shutter by first removing the screw
from the underside of the grille then unclipping the bottom of the grille, the top of
the grille can then be released by unclipping the top corner. The shutter can then
be unclipped. NOTE: The top of the grille can only be released when the screw is
removed and the bottom of the grille has been released (Fig. 2).
j
To allow trickle ventilation:
2. Release the Shutter Return Spring as shown in Fig. 10.
3. Re-position the Shutter Return Spring into the L-shaped slot.
4. Raise the Operating Bar to latch into position.
j
To fully close the shutters and stop any backdraught:
5. Unlatch the Shutter Return Spring and re-position into the short slot.
6. Refit the Back Draught Shutter and Inner Grille.
L
Cleaning
1. Before cleaning, isolate the fan from the mains supply. Allow 3 minutes for the
impeller to stop rotating and the powered shutter to close.
2. Remove the inner grill and back draught shutter by first removing the screw
from the underside of the grille then unclipping the bottom of the grille, the top of
the grille can then be released by unclipping the top corner. The shutter can then
be unclipped. NOTE: The top of the grille can only be released when the screw is
removed and the bottom of the grille has been released (Fig. 2). WARNING: The
fan will still operate when the inner grille is removed.
3. Remove the impeller by unscrewing the knob at the front of the impeller.
anticlockwise.
4. Clean the inner grille, back-draught shutter and impeller by immersing in warm
soapy water. Dry thoroughly.
Do not immerse the fan in water or other liquids to clean any other parts of the
fan.
5. Refit the impeller by locating it over the motor shaft and aligning the arrow on
the impeller with the white dot on the motor. Make sure the impeller is seated
correctly.
6. Refit the knob making sure the ratchet at the rear of the knob is fully engaged.
j
Never use strong solvents to clean the fan.
j
Apart from cleaning, no other maintenance is required.
Inner Grille.........................................."A"
Ladder Strips.................................."F"
Back Draught Shutter........................."B"
Connector Plate.............................."G"
Fan Assembly ....................................."C"
Rating Plate ...................................."H"
Inner Clamp Plate..............................."D"
Selector Switch (GX9 only)............"J"
Outer Clamp Plate/Grille....................."E"
Cord (GXC9 only)..........................."K"
USING YOUR FAN
LOOKING AFTER YOUR FAN
KEY (For Fig. 11)
I
LAS CIARE QUESTO FOGLIETTO DI ISTRUZIONI
INSIEME AL VENTILATORE, PER USO DA PARTE
DELL'UTENTE.
18
Si devono sorvegliare i bambini, per assicurarsi che non giochino con
l’apparecchio.
Per eventuali chiarimenti, prima o dopo l’installazione dei prodotti, è
possibile rivolgersi all’assistenza tecnica Xpelair chiamando il numero
+44 (0) 8709 000530. Per parlare con i nostri tecnici chiamare durante il
normale orario di uffici (solo per il Regno Unito altrimenti è possibile inviare
in qualsiasi momento un fax chiamando il numero: +44 (0) 7809 000530.
I ventilatori GXC9
(con azionamento a cordicella) e GX9 hanno le
seguenti caratteristiche:
= Montaggio su finestra, a parete, su pannello o a soffitto.
= Sono muniti di serrandina antiricircolo a funzionamento silenzioso, (GX9).
= Il modello GX9 può espellere l’aria, aspirarla o aprire “solo la serrandina”
(arresto completo), usando un interruttore di selezione incorporato nel
ventilatore.
= Regolazione per ventilazione leggera di fondo.
# &venireinstallatocondispositivodicontrollo(soloilmodelloGX9).
Sevieneinstallatocondispositivodicontrollo,ilGX9&aspirareo
espellerel’ariaavelocitàprestabiliteoavelocitàvariabile,asecondadel
tipodiregolazione.Seèconacceso/spentoilGX9
aspireràoespelleràl’ariaadaltavelocità.
Sesiinstallailventilatoreconacceso/spento:
= Cavetto a 3 conduttori.
= Nel cablaggio fisso deve essere inclusa la possibilità di uno
scollegamento fisico dall’alimentazione su tutti i poli in conformità con le
norme sui cablaggi.
= Un cacciavite grande con lama da 6 mm, un cacciavite da elettricista con
lama da 3 mm, cacciaviti Pozidriv° N°1 e N°2.
Seilventilatorevienemontatoapareteoccorreanche:
= Malta (per riparare il foro).
= Kit per parete WK9/8 o WK9/11 (ottenibile dalla Xpelair) o un tubo con
diametro interno di 253 mm.
Seilventilatorevienemontatoinfinestra,occorreràanche:
= Una finestra fissa con vetro semplice dello spessore minimo di 4 mm.
Seilventilatorevienemontatoasoffittooccorreràanche:
= Una mitra per il tetto, modello RC9.
= Nel caso di installazione su tetto piano, una piastra per montaggio a tetto
tipo XRP9/12 (entrambi questi due articoli ottenibili dalla Xpelair).
Seilventilatorevienemontatoinsiemeadregolatore(soloilGX9):
= Cavo a 5 conduttori. Nota: seguire le istruzioni fornite con il regolatore.
= Montatelo quanto più in alto possibile.
= Dal centro del foro ai bordi della parete o dell’intelaiatura della finestra ci
devono essere come minimo 205 mm.
= Quanto più lontano possibile e dalla parte opposta della sorgente principale
di ricambio dell’aria, in maniera da assicurare un flusso d’aria attraverso la
stanza (ad es. dalla parte opposta della porta interna d’ingresso).
= Vicino alla sorgente di vapore o degli odori.
= Non in abbienti la cui temperature possa superare 50 °C.
5
Se il ventilatore viene installato in una stanza dove si trova
un’apparecchiatura che fa uso di combustibile, si devono prendere
precauzioni per evitare il riflusso di gas nell’ambiente dalla canna
fumaria del bruciatore.
5
L’aria di scarico non deve essere fatta uscire attraverso una canna
fumaria usata per i gas di scarico di altre apparecchiature.
5
Per le portate d’aria di rinnovo e per l’espulsione dell’aria osservare
tutti i regolamenti delle autorità competenti.
5
Se il ventilatore è inteso per l’aspirazione dell’aria, la griglia di
ingresso deve essere posizionata come minimo alla distanza di
0,5 metri dall’uscita di scarico di una canna fumaria usata per una
apparecchiatura di riscaldamento o per cucinare.
5
Quando si intende usare il ventilatore in atmosfere soggette a
sostanze chimiche corrosive occorre consultare il nostro Reparto
Assistenza Tecnica.
5
Questo prodotto non deve essere installato in zona 0.
5
Questo prodotto elettrico, se installato in una sala con doccia o da
bagno, deve essere collocato in posizione tale da non potere essere
toccato da chi fa uso della doccia o del bagno.
1.Verificare che sul retro della posizione dell’interruttore (nella parete o
sopra il soffitto) non ci siano tubi o cavi incassati dell’elettricità, del gas o
dell’acqua.
2.Installare il cavo dal sezionatore alla posizione del ventilatore.
3.Installare il cavo dal sezionatore al punto di connessione alla rete
elettrica di alimentazione.
4.Installare il sezionatore.
5.Fare tutti i collegamenti all’interno del sezionatore.
AVVERTIMENTO: non fare a questo punto connessione alcuna con la
rete elettrica di alimentazione.
1
Descrizione
2
Occorrente per l’installazione
3
Dove posizionare il ventilatore
ai regolamenti IEE correnti, negli altri Paesi ai regolamenti vigenti del
pratica professionale relativi all’edilizia. Non è previsto l’uso di questo
menomazioni fisiche, sensoriali o mentali, o mancanza di esperienza
4
Installazione del sezionatore e del cablaggio
Questi apparecchi sono progettati per essere collegati per mezzo di
cablaggio fisso. Verificare che i dati elettrici indicati sul ventilatore
corrispondono a quelli della rete di alimentazione.
Tutte le installazioni devono essere controllate da un elettricista
qualificato.
L’installazione e il cablaggio devono conformarsi: in Gran Bretagna
ai regolamenti IEE correnti, negli altri Paesi ai regolamenti vigenti del
posto.
AVVERTIMENTO: QUESTI APPARECCHI DEVONO ESSERE
COLLEGATI A TERRA.
Chi esegue l’installazione è responsabile di osservare i codici di
pratica professionale relativi all’edilizia. Non è previsto l’uso di questo
apparecchio da parte di persone (inclusi i bambini e gli infermi) con
menomazioni fisiche, sensoriali o mentali, o mancanza di esperienza
e conoscenze, a meno che tali persone siano sorvegliate o istruite
sull’uso dell’apparecchio da una persona responsabile della loro
sicurezza.
INSTALLAZIONE DEL VENTILATORE
Instruzioni d’installazione ed uso,
Xpelair GX9 e GXC9:
Содержание GX9 and
Страница 1: ......
Страница 2: ...Step 3 Step 2 Step 1 Step 3 ...
Страница 4: ...A B J C G D F H K E 4 ...
Страница 22: ...22 ...