Removing the cover gives access to the PCB for power connection and speed control settings.
Locate the PCB termination plug
which comes plugged into the
termination socket on the PCB
Identify the correct power and control
connections for your system requirements
Connect the power and control
wires to the PCB termination
plug and fix with a screw driver
Align the PCB termination plug with
the PCB termination socket
Firmly connect the two sides of the
plug
Fix the cables by either;
Routing the cable in the labyrinth
Fixing with the cable clamp
NOTE:
If using the labyrinth, ensure the cable is securely fitted inside the entire length of the labyrinth.
If using the cable clamp, ensure the cable is an appropriate diameter to achieve a firm grip.
If you have any queries regarding the installation of this product, please call the Technical Hotline. Our engineers are there to help