10 

December 2020 

 08/100245/0           

 

 

User Information 

Your home has been fitted with a highly energy efficient mechanical ventilation system.  The system should consist of an Everdri 
XEL  central  mechanical  supply  fan,  ducting  and  discharge  diffuser.  The  correct  working  system  will  provide  a  healthy  indoor 
atmosphere and will help eliminate condensation and unwanted odours by supplying filtered fresh air into your home.  

The fan is designed to run continuously 24 hours a day. It is fitted with an energy efficient electronic motor. 

Manual Override Switch Control Options 

The  Everdri  XEL  system  is  supplied  with  a  Manual  over-ride  switch,  allowing  you  to  switch  between  a  low  trickle  speed  (in 
Automatic mode) and 2 additional speeds in Manual mode. The high-speed setting 

 is a boost position to allow for the extract of 

cooking smells or moisture-laden air. When in use, it is advisable to open window vents or a window to allow the moisture laden air 
to  escape.    The  middle  position  would  be  the  normal  running  position  in  a  house  with  the  low  speed  position  as  a  background 
position if the house is not fully occupied.  In a smaller dwelling or flat the low speed position could be the normal running position 
with the middle position as boost. 

 

▲    ▲ 

Trickle Mode 

 

▲    ▼ 

Speed 1 

 

▼    ▼ 

Speed 2 

Maintenance  

The fresh air input is protected by a G4 filter which should be annually inspected, cleaned and if required replaced. The following 
procedure can easily be used to remove the filter for cleaning or to be replaced if necessary.  

 

WARNING: Make sure that water does not get into the motor or 
electrical termination box during cleaning.

 

 

Rotate filter locking tabs through 90 degrees 

 

Lift filter straight up taking care not to drop dust into the fan 

 

 

NOTE: 
It is advisable to have the unit inspected by your installer annually.

 

Содержание Everdri XEL

Страница 1: ...ts reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex Glen Dimplex UK LTD trading as Glen Dimplex Heating Ven...

Страница 2: ...nit via the G4 filter on the cover The casing incorporates a 125mm spigot for easy connection to the supplied ducting Safety Instructions This ventilation unit is intended exclusively for the ventilat...

Страница 3: ...fuser Mounting Ring 8 200mm Supply Air Diffuser 9 Duct Heater Everdri XELH Version Only Position of air supply diffuser It is recommended that the supply air diffuser is installed in a central locatio...

Страница 4: ...Care should be taken to ensure ducting is as straight and uncompressed as possible with minimal bends This will reduce resistance in the air flow path allowing greater performance at lower speed setti...

Страница 5: ...erature probe from the heater as shown on the right 9 Push the adapter onto the installed diffuser mounting ring NOTE When testing the ventilation unit check the ducting for any air leaks and seal wit...

Страница 6: ...Firmly connect the two sides of the plug Fix the cables by either Routing the cable in the labyrinth Fixing with the cable clamp NOTE If using the labyrinth ensure the cable is securely fitted inside...

Страница 7: ...Speed 2 Control L Trickle Speed Using a small long handle screw driver adjust the potentiometer as required by turning the knob using the central slot Turn clockwise to increase speed Turn anti clockw...

Страница 8: ...8 December 2020 08 100245 0 Alternative Switch Option Connection with a three speed selector switch Connection with sensors or several change over switches...

Страница 9: ...oke or CO detector must be normally closed NC and will go open circuit OC in the event of a fire When the ventilation unit detects an open circuit the fan will stop to prevent feeding fresh air to a f...

Страница 10: ...the extract of cooking smells or moisture laden air When in use it is advisable to open window vents or a window to allow the moisture laden air to escape The middle position would be the normal runni...

Страница 11: ...ours LED on for 2 short flashes 3000 to 4000 hours LED on for 3 short flashes 4000 to 5000 hours LED on for 4 short flashes 5000 to 6000 hours LED on for 5 short flashes 6000 to 7000 hours LED on for...

Страница 12: ...f 21856AW Time Delay Unit DT20B Ref 21850AW Air Quality Sensor AQS Ref 92097AW Three Speed Selector Switch Ref 91266AW Three Speed Controller Ref 91457AA Ancillaries Duct Heater Ref 300001022 Raises t...

Страница 13: ...for 5 years from date of purchase Xpelair reserve the right to repair or replace the unit Keep your purchase receipt Any problems contact the address below Outside the UK See International section In...

Страница 14: ...The ventilation unit has been packaged carefully to protect it from damage during transport The transport packaging consists of recyclable raw materials Please ensure to dispose of it in an environmen...

Отзывы: