If wall moun
ting
the fan, you will also need:
•
A 150mm diameter prepared hole.
•
An appropriate external Wall Grille and Ø150mm wall sleeve duct. Kit Ref 91233AW.
If ceilin
g
moun
ting
the fan, you will also need:
•
A 150mm diameter prepared hole.
•
Appropriate ancillaries for termina
�o
n. These items are available from Xpelair:
•
3m
fl
exible du
c�
ng Ref: 89665AA. If the duct passes through a cold space use insulated duct ref: 91461AA.
1.
2.
3.
4. Lay in the cable from the isola
�
ng switch to the fan loca
�o
n via the on/o
ff
switch (if required).
5. Lay in the cable from the isola
�
ng switch to the point of conne
c�
on to the mains supply.
6. Install the isola
�
ng switch and on/o
ff
switch (if required).
7. Make all conne
c�
ons within the isola
�
ng switch and the on/o
ff
switch (if required).
•
Locate it as high as possible.
•
At least 110mm from the edges of the moun
�
ng surface to the centre of the hole.
•
As far away as possible from and opposite to the main source of air replacement to ensure
airflo
w across
the room (e.g. opposite the internal doorway).
•
Near the source of steam or odours.
•
•
•
•
•
3mm electrician’s screwdriver and No.1 or 2 Pozidrive screwdrivers.
A means for disconne
c�
on in all poles must be incorporated in the
fix
ed wiring in accordance with wiring
regula
�o
ns
•
•
The cross-se
c�
onal area of the supply cord used should not exceed 1.0mm².
•
C6S / C6R / C6PS / C6PR – 2 core, C6TS / C6TR / C6HTS / C6HTR – 3 core.
•
C6TS / C6TR / C6HTS / C6HTR. A wall or ceiling On/O
ff
switch (with indicator light) is recommended