background image

If wall moun

ting

 the fan, you will also need: 

A 150mm diameter prepared hole.

An appropriate external Wall Grille and Ø150mm wall sleeve duct. Kit Ref 91233AW.

If ceilin

g

 moun

ting

 the fan, you will also need: 

A 150mm diameter prepared hole.

Appropriate ancillaries for termina

�o

n. These items are available from Xpelair:

3m 

exible du

c�

ng Ref: 89665AA. If the duct passes through a cold space use insulated duct ref: 91461AA.

1.

2.

3.

4. Lay in the cable from the isola

ng switch to the fan loca

�o

n via the on/o

 switch (if required).

5. Lay in the cable from the isola

ng switch to the point of conne

c�

on to the mains supply.

6. Install the isola

ng switch and on/o

 switch (if required).

7. Make all conne

c�

ons within the isola

ng switch and the on/o

 switch (if required).

Locate it as high as possible.

At least 110mm from the edges of the moun

ng surface to the centre of the hole.

As far away as possible from and opposite to the main source of air replacement to ensure 

airflo

w across

the room (e.g. opposite the internal doorway).

Near the source of steam or odours.



3mm electrician’s screwdriver and No.1 or 2 Pozidrive screwdrivers.

A means for disconne

c�

on in all poles must be incorporated in the 

fix

ed wiring in accordance with wiring 

regula

�o

ns


The cross-se

c�

onal area of the supply cord used should not exceed 1.0mm².

C6S / C6R / C6PS / C6PR – 2 core, C6TS / C6TR / C6HTS / C6HTR – 3 core.

C6TS / C6TR / C6HTS / C6HTR. A wall or ceiling On/O

 switch (with indicator light) is recommended

Содержание C6S

Страница 1: ...fore a emp ng to make electrical connec ons or carry out any maintenance or cleaning Please leave this lea et with the fan for the bene t of the user UK customers If you have any queries before or a e...

Страница 2: ...he integral humidity sensor or by using an external on o switch not supplied the built in mer automa cally operates the fan for a pre set delay me from 30 seconds to 30 minutes once humidity drops bel...

Страница 3: ...Back plate xing posi ons Wall tube quick x clamps Front Cover Removal Minimum 30 seconds Maximum 30 minutes Factory se ngs Timer 15 minutes RH 75...

Страница 4: ...Wiring and se ng up...

Страница 5: ...e isola ng switch and on o switch if required 7 Make all connec ons within the isola ng switch and the on o switch if required Locate it as high as possible At least 110mm from the edges of the moun n...

Страница 6: ...c ng 6 Drill screw holes in these posi ons if necessary and t wall plugs and screws as required The fan may also be xed to a wall tube using the clamping brackets See 9 below Mount the back plate 7 Fe...

Страница 7: ...dity levels without opera ng the fan If the humidity levels increase at a rate slower than 5 RH in 5 minutes up to the pre set humidity level the fan will not be triggered by humidity This is to preve...

Страница 8: ...utor Xpelair A brand of Glen Dimplex Hea ng Ven la on Glen Dimplex UK Ltd Glen Dimplex Europe Limited Millbrook House Grange Drive Hedge End Southampton SO30 2DF Airport Road Cloghran Co Dublin K67 VE...

Отзывы: