To Adjust the Press Head for a NEW Pail Closure Position:
CAUTION:
Only qualified service or maintenance personnel should
attempt this adjustment.
With AIR connected to the Press, place an empty bucket with A FULLY PRESSED LID
under the Press Head. Remove the Main Air Line from the Air Regulator from the back
of the machine.
Locate the Control Valve, which is located on the side of the vertical I-Beam. With air
removed from the press, swap tubes A and B so you have inserted Tube A into Port B
and Tube B into Port A.