17
System set up
Auto-start
When the desired yes or no option is displayed press the output on/off button to select it. After selection the following screen
will be displayed:
System set up
exit
To change another setup item at this time you may use either rotary control to select that option. To exit setup, rotate either
control until the following screen is displayed then press the output on/off button.
Save config?
yes
The following screen will be displayed.
Save config?
no
Rotating either control will alternate between the screen above and the screen below.
When the desired option is displayed press the output on/off button. Selecting YES will save any Setup changes to non-volatile
memory and they will be retained even when primary power is cycled. Selecting NO will not save Setup changes to non-volatile
memory and they will be in effect only until the unit is turned off.
The power supply will return to normal operating mode at this time.
7.2.4 Remote Sense Setup
Most power supplies with remote sense require a second set of wires between the power supply and the load to sense the
voltage at the load. The PLS600 supply uses proprietary technology to digitally compensate for these resistances without the
extra sensing wires. Prior to using the Remote Sense option a simple load calibration must be performed. This section will detail
how to enable Remote Sense and how to do the calibration required. Once in setup mode rotate either control until the REMOTE
SENSE screen is displayed then press the output on/off button. The following screen will be displayed.
Remote Sense
ON