Regularly, press to re-Tune the threshold (coil barely off the ground
2 to 5 cm/ 1 to 2 inches). How frequently you recalibrate will be linked to
ground variations or temperature.
On Wet Beach, select program 7 before using the Non Motion Mode
and use
Non-Motion Audio Disc
mode with
G.B.
at 15/27.
Position the coil barely off the ground (2 to 5 cm/ 1 to 2 inches).
Set the Sensitivity to stabilize the detector during sweeping. Then
adjust the Tune to obtain an audio threshold barely audible.
Position the coil barely
off the ground (2 to 5
cm/ 1 to 2 inches) and
to the side of the target.
Press to calibrate the
threshold.
PINPOINT
MODE
Move the coil slowly across
the target. The loudest
sound and highest audio
pitch indicates the target
position.
To narrow the field of
detection and to improve
the target location:
Position the coil, close to
the target but not on the
center. Press to re-tune
the threshold then locate
the target as step 2.
21
Meter Accept/Reject
- TUNE :
allows to calibrate threshold to
the ground.
- SENS :
adjust the depth.
MODE
: allow to choose between 4 modes :
Used to access the
NON-MOTION
mode
and/or to update the threshold(re-
TUNE)
.
The non - motion mode allows the user to operate the coil motionless above a target. It is useful
to locate metal targets inside houses, cellars; also it is widely used to follow underground metal pipes.
1-Pinpoint:
to locate metal targets
2-Non-motion Audio Disc
: audio
tone upwards for good targets and
down for ferrous. Application: general
use, mineralised ground
3-Non-motion All Metal
: All Metal +
will also detect anomaly’s in ground
minerals plus some ceramics
4-Non-motion Disc
: discrimination
with single tone. Application: search
inside walls.
-
OUI
- GROUND
: adjust the ground balance.
- DISCRI:
adjust the rejection of undesirable
targets.
NON MOTION DISC
– NON MOTION AUDIO DISC & ALL METAL
NON MOTION AUDIO DISC
TUNE
SENS
MODE
GND
REJECT ACCEPT
"Ground value"
Adjust value
manually
15 cm
~
Non-motion Audio Disc
and
Non-motion All Metal
both require
fine adjustment of the ground balance. This adjustment will make the
Sensitivity and Tuning parameters easier to control which will make
the detector more stable.
Pump the coil, and enter the observed "ground value" with
-
PINPOINT
(
localisation
)
1
2
3
NON-MOTION DISC requires no adjustment of ground balance, it is
useful to locate metal targets inside walls weakly mineralised, and
gives a good distinction between ferrous and non-ferrous. Set this
mode, as indicated in step 2.
NON MOTION AUDIO DISC
SENS
G.B