- 16 -
LED LIGHT REPLACEMENT
The LED light modules are held in place by
spring clips which must be squeezed in be-
fore the lamp can be pushed down through
the fascia.
Unplug the plastic molex connector.
Plug in the new fixture and snap back into
place.
XOP
SPK6602
maintenance continued
XORFSQR
FOR UNITS USED IN RECIRCULATION MODE ONLY:
This refers to hoods which are not ducted outside but rely instead on carbon filter elements
to help purify the air before it is exhausted back into the room.
The carbon element filters gradually lose efficiency and cannot be cleaned or regenerated.
These must be replaced at least 4 times a year, more frequently if needed based on the
amount of use and style of cooking.
CHANGING THE CARBON FILTERS:
Changing the filters is easy.
To Reduce the Risk of Fire and Shock use only
conversion Kit Model
XORFSQR
(ACK00083)
Filters.
The
XORFSQR
filters are sold in pairs.
To replace the filters, unlatch and remove the
Anti-Grease filters.
This will expose the blower.
Remove the old filter as shown in the figure and
install the new filter simply align and push into
place to lock.
(UL REFERENCE ACK00083)
Содержание XOQ30GC
Страница 1: ...I worked really hard on this manual so please read it XOQ WALL MOUNT MODELS XOQ30GC XOQ36GC ...
Страница 2: ......
Страница 11: ... 11 Front of hood Side of hood Top of hood DIMENSIONS MODEL A XOQ30GC 30 XOQ36GC 36 Duct cover removed ...
Страница 21: ...J ai travaillé très dur sur ce manuel veuillez donc le lire XOQ WALL MOUNT MODÈLES XOQ30GC XOQ36GC ...
Страница 40: ...He trabajado mucho en este manual así que léalo XOQ WALL MOUNT MODELOS XOQ30GC XOQ36GC ...
Страница 59: ......
Страница 60: ...3011000130200 00 ...