2. CONNECT ELECTRICAL:
• Power Supply Connection:
For connection to the power supply refer to the
follows
Fig.7
:
BLACK
=
L
line
WHITE
=
N
neutral
GREEN/YELLOW
=
G
ground
- A double-pole switch properly rated must be
installed to provide the range hood power supply
disconnection.
- Connect the electrical conduit to the Field Wiring
Compartment using listed conduit fittings.
- Carry out the power supply connection in accor-
dance with the national electric code, ANSI/NFPA
70-1999.
5. Insert the wires into the box, then close the box
cover, securing it using the s c r e w s t h a t w e r e
p r e v i o u s l y removed.
The appliance should be installed at a minimum
height of 24" up to a maximum height of 32" for op-
timal performance. If a connection ductwork com-
posed of two parts is used, the upper part must be
placed outside the lower part. Do not connect the
range hood exhaust duct air to the same duct air
used to exhaust hot air or fumes from other appli-
ances other than electrical.
•
In the
FILTERING
version it is necessary to apply a
metal air exhaust tube
M (Fig.8)
, with a minimum
length of 15", connected to the flange of the col-
lector. It must be positioned vertically and fastened
to a specific opening made on the top part of the
cabinet.