XM1630S Software Reference Manual
No. XM1630S-A00-104
xmodus swiss GmbH
8 / 32
3.1 Web based LAN configuration
The LAN Configuration Screen allows configuration of all the LAN specific parameters
such as IP address, subnet mask, gateway IP address, Ethernet speed and DHCP
server.
LAN configuration screen:
Important:
The LAN configuration menu contains a validation procedure, which prevents the
storing of incorrect configuration data. After a setting has been changed and saved,
the new configuration must be validated within 3 minutes by reconnecting via the
Browser and clicking on the <Modify / validate settings> button. After this timeout with
no validation, the module returns to the previous configuration so that it cannot be left
in an unreachable condition.
Procedure:
Change settings as desired
Click on <Modify/validate settings> followed by <Save changes*>
The LAN modem will now reboot with its new settings. Reconnect using the
new settings to ensure that it is reachable.
Click on <Modify/validate settings> to validate the new settings so that they are
permanently used.
If after 3 minutes no validation has taken place the previous configuration is
automatically
restored.