3.4 Web based I/O configuration
The I/O configuration screen provides all the settings to configure the I/O and ADC
ports plus the LED output lines. It allows read and write operations on predefined
hardware ports.
3.4.1 Configure LED outputs:
Port 0:
This port is configurable as “Link” LED or user defined output by either the
Link or the User radio button. The “present state” field shows the actual state of
the port.
Port 1:
This port is configurable as “Speed” LED or user defined output by either
the Link or the User radio button. The “present state” field shows the actual state
of the port.
Port 2:
This port is configurable as “Collision” LED or user defined output by
either the Link or the User radio button. The “present state” field shows the actual
state of the port.
Port 3:
This port is configurable as “Run” LED or user defined output by either the
Link or the User radio button. The “present state” field shows the actual state of
the port.
3.4.2 Configure I/O and ADC:
Port 4 – 8:
These ports are configurable as Input, Output or ADC ports by either
the “Input”, “Output” or “ADC” radio buttons. The “present state” field shows the
actual state of the port. The “ADC value” files shows the hexadecimal equivalent
of the analog input level.
Read new port values and ADC samples.
Refresh Display