background image

 

USER MANUAL

 

Optima Rack 1-3K

 

___________________________________________________________________________________________________________________________________ 

(120217_EN) OPTIMA-RACK 1K-3K

 

  

21

 

 

*  Any of following codes indicated on 
LCD:  
1, 2, 3, 4, 11, 12, 13 o 41 
* Continuous beep 

Internal Ups failure detected. 
UPS working in any of following 
modes: 
1. UPS output powered in 
BYPASS mode 
2. UPS outlets powered off  

Call service support

Very short backup time 

Batteries  can  be  discharged 
because recent use.. 

Let UPS recharge batteries 
during 6 hours before check 
backup time again.  

Battery can be degraded 
because long lifetime. 

Batteries must be replaced by 
new batteries. 

* Intermittent: 

 + 

 

* 1 beep per second.  

FANs blocked or damaged

Check FANs and call service 
support if problem cannot be 
solved 

 

 
13. CONTROL SOFTWARE 

Our control software offers huge capabilities to monitor your UPS and configure key shutdown parameters. Also 
event and data log are available in software options.  
Main software features are: 

 

Friendly human interface to UPS. 

 

Controlled files saving and OS shutdown when blackout is detected. 

 

Configurable scheduled shutdown and Auto-tests 

 
Some UPS models include software CD inside the box. Others allow software downloaded from our website: 
www.xmart-ups.com.  
 

 

USER MANUAL

 

Optima Rack 1-3K

 

___________________________________________________________________________________________________________________________________ 

(120217_EN) OPTIMA-RACK 1K-3K

 

  

22

 

 
14. WARRANTY AND SUPPORT 
 

Support: 

When a failure or problem is detected please check troubleshooting table in this manual. If problem cannot be solved 

please contact authorized service center or authorized dealer. 

 

Batteries:

 Rechargeable batteries can be charged and discharged hundreds of times. However they will eventually wear out. This is 

not a defect or failure so that batteries wear out is not covered by warranty. 

Battery lifetime will depend of operative conditions like working temperature and type and frequency of discharging cycles. Higher 

the temperature shorter will be the lifetime. Frequent and deep discharging cycles also will short lifetime. For critical applications 

batteries should be revised and replaced periodically. 

Long storage without required recharging will wear out batteries. This situation is not covered by this limited warranty since this is 

not considered as a defect. Check recharging instructions on user manual. 

 
Conditions Limited Warranty “Xmart-PRO11” 

1.- Subject to the conditions of this limited warranty, this product is warranted to be free from defects in materials and workmanship 

at the time of its original purchase by end user and for subsequent period of 1 year on electronic parts and 1 year on batteries. This 

standard warranty time could be extended depending on the country/region or as an option. Please check warranty times by 

country/region in our web www.xmart-ups.com. 

2.- If during the warranty period, this product fails to operate under normal use and service, due to defects in materials or 

workmanship, authorized distributor or service center will, at their option, either repair or replace the product in accordance with 

terms and conditions stipulated herein. Transportation expenses are not covered by this limited warranty. 

3.- Warranty is valid only if the original purchasing document issued to original purchaser by authorized distributor or dealer, 

specifying date of purchase, serial number and name of the dealer, is presented with the product to be revised. XMART and 

authorized partners reserve the right to refuse warranty service if any of this information has been removed, changed or missing in 

original purchasing document. 

4.- If product is repaired or replaced, repaired or replaced product will be warranted for the remaining time of the original warranty or 

for 90 days from date of repair or replacement, whichever is longer. 

5.- XMART or their distribution/service partners reserve the right to charge handling fee if returned product is free of failure or out of 

warranty period because any of the reasons described in this warranty.  

6.- If product is out of warranty a reparation or replacement proposal will be sent to the user for his approval. If customer does not 

approve reparation, `product will be available to be picked up during 60 days. After this period product would be disposed by service 

center and user will not be able to rises any claim.  

7.- Rechargeable batteries will definitively wear out even under normal operation and conditions. This is not a defect or failure so 

that it is not covered by this warranty. 

8.- Warranty does not cover product failures caused by: improper storage or longer than 6 months storage without required 

recharging, inadequate installation or maintenance, misuse, accidents, fire or floods. In these cases warranty will be considered 

void. 

9.- This warranty does not cover product failures caused by installations, modifications or repair or opening of the product performed 

by non authorized person. 

10.- This product can include protection devices like input fuse or input breaker. Activation of this kind of devices is not a failure it is 

caused by an improper product installation. Input fuse or breaker can be easily reset or replaced by user.  

11.- This warranty does not cover damages produced during transportation from user to technical service caused by improper 

packing of the product by user. 

12.- Warranty time could be extended depending on market or products. Contact your authorized dealer for additional information. 

13.- Warranty terms and conditions cannot be modified or extended by third parties without written approval of XMART. 

 

Limited Warranty “Xmart-PRO11” 

- If hardware product fail to work as warranted above, the maximum liability of XMART under this limited warranty is expressly 

limited to the lesser of the price you have paid for the product or the cost of repairing or replacement of any hardware components 

that malfunction in conditions of normal use. 

- In no event will XMART be liable for any damages caused by the product or the failure of the product to perform, including any lost 

profits or savings or special, incidental, or consequential damages. XMART is not liable for any claim made by a third party or made 

by you for a third party.  

- XMART does not warrant that the operation of this product will be uninterrupted or error-free. XMART is not responsible for 

damage that occurs as a result of your failure to follow the instructions intended for this hardware product. 

 

Содержание OPTIMA-RACK 1KVA

Страница 1: ...care Do not block UPS ventilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT connect...

Страница 2: ...1 2003 An Uninterruptible Power Systems UPS Part 1 1 General and Safety Requirement for UPS use operator access areas EMC Directives EN62040 2 2006 An Uninterruptible Power Systems UPS Part 2 Electro...

Страница 3: ...TON FUNCTIONS ON MUTE a POWER ON Keep selected during 2 seconds or longer b BEEP MUTE In battery mode Keep selected during 5 seconds or longer to Mute acoustic alarm beep Some alarms cannot be muted a...

Страница 4: ..._____________________________________________________________________________________________ 120217_EN OPTIMA RACK 1K 3K 8 3 2 RACK UPS INSTALLATION Rack UPS must be installed using L Shape type guid...

Страница 5: ...OPTIMA models but they can also be connected at any moment to EX BATT supplied by XMART Special cables to connect EX BATT to UPS are supplied inside the box of EX BATT USER MANUAL Optima Rack 1 3K ___...

Страница 6: ...power from batteries There is no dead time transition time is ZERO ms related to switching from normal mode to battery mode since load is always powered from inverter This is main characteristic of a...

Страница 7: ...ry charging level 0 25 26 50 51 75 y 76 100 Indicates battery failure Indicates low battery level Input Information Indicates input voltage input frequency and DC battery voltage Vac Input voltage Vdc...

Страница 8: ...ts To able or disable programmable outlets function 09 Programmable To configure timer value in minutes for programmable outlets USER MANUAL Optima Rack 1 3K __________________________________________...

Страница 9: ...as selected BATTERY MODE When AC input source is out of range Ups goes to battery mode to supply output from taking energy from batteries USER MANUAL Optima Rack 1 3K _________________________________...

Страница 10: ...push button is not been selected properly Push ON button during 2 seconds or longer 1 beep s alarm is active and LCD shows Input Line and Neutral are swapped Rotate UPS plug at wall socket to allow c...

Страница 11: ...th terms and conditions stipulated herein Transportation expenses are not covered by this limited warranty 3 Warranty is valid only if the original purchasing document issued to original purchaser by...

Страница 12: ...ries Step 2 Take out battery kit from UPS Step 3 Replace old batteries using equivalent batteries with same voltage and capacity in AH Follow instructions of 15 3 Step 4 Reconnect batteries assembly b...

Страница 13: ...apacidad 1100VA 800W 1700VA 1200W 2250VA 1600W 3400VA 2400W Range Rango Vac 100 load Model 120V 80Vac 150Vac Model 220V 160Vac 300Vac Range Rango Vac 50 load Model 120V 50Vac 150Vac Model 220V 110Vac...

Отзывы: