Optima Rack 1-3K

 

___________________________________________________________________________________________________________________________________ 

(120217_EN) OPTIMA-RACK 1K-3K

 

  

1

 

 

 
 

ENGLISH 

 

 

 
 

USER MANUAL 

OPTIMA-RACK 1K – 3KVA 

ONLINE DOUBLE CONVERSION UPS 

 

User Manual:  

 

220V (Europe: «Schuko» Zone) 

 

110V (America: «NEMA» Zone) 

 

 

 

 

 

 

 
 

 

 
 
 
 
 
 

 

USER MANUAL

 

Optima Rack 1-3K

 

___________________________________________________________________________________________________________________________________ 

(120217_EN) OPTIMA-RACK 1K-3K

 

  

2

 

DO NOT connect laser printers, scanners, or copiers to this UPS. 

High power devices may damage this UPS

 

 

1. SAFETY AND USE: 

 
WARNING

: This product has been designed to operate safely and reliably for years. Nevertheless, as it is an 

electrical device, it is required to read and understand this manual. Keep manuals as references for future consults. 

 
WARNING

: This product has been designed to be used indoors, protected of water, direct sun light and extreme 

temperatures. This device must not be used outdoors, close to moisture of heat sources.

 

 
WARNING

: Do not set objects on this UPS. Handle with care. Do not block UPS ventilation.

 

 
WARNING

: Make sure to connect this unit to proper power line according to selected model. The UPS Technical 

Specs sticker shows power rating information. DO NOT connect this UPS to any of its own power outlets. 

 
WARNING

: UPS must be installed following instruction from this manual. 

The manufacturer is not liable for any damage that might rise from misusing this unit or defective installation. 

 
WARNING

: Only computer related equipment can be connected to this UPS. DO NOT connect medical 

equipments, life support equipments, microwave ovens, vacuum cleaners, refrigerators, or any other appliance to 
this UPS. 

 
WARNING

: UPS must be checked, repaired and maintained by qualified personnel only. This product is locked by 

screws. 

 
WARNING – ELECTRIC SHOCK RISK

:  

Inside the UPS there are dangerous high voltages even when disconnected of power line, due to internal batteries 

 
WARNING:

 In case of emergency turn off the UPS pressing Power Button, unplug it and call technical support. 

 

 
 
 
 

 
Disposal 

We strongly recommend disposing this UPS according to regulations in your country to prevent 
possible environmental damages; besides some parts might be recycled. 

 
BATTERY WARNING

: DO NOT dispose batteries in fire as it might explode. DO NOT try to open 

batteries, there are dangerous liquids inside. 

Содержание OPTIMA-RACK 1KVA

Страница 1: ...care Do not block UPS ventilation WARNING Make sure to connect this unit to proper power line according to selected model The UPS Technical Specs sticker shows power rating information DO NOT connect...

Страница 2: ...1 2003 An Uninterruptible Power Systems UPS Part 1 1 General and Safety Requirement for UPS use operator access areas EMC Directives EN62040 2 2006 An Uninterruptible Power Systems UPS Part 2 Electro...

Страница 3: ...TON FUNCTIONS ON MUTE a POWER ON Keep selected during 2 seconds or longer b BEEP MUTE In battery mode Keep selected during 5 seconds or longer to Mute acoustic alarm beep Some alarms cannot be muted a...

Страница 4: ..._____________________________________________________________________________________________ 120217_EN OPTIMA RACK 1K 3K 8 3 2 RACK UPS INSTALLATION Rack UPS must be installed using L Shape type guid...

Страница 5: ...OPTIMA models but they can also be connected at any moment to EX BATT supplied by XMART Special cables to connect EX BATT to UPS are supplied inside the box of EX BATT USER MANUAL Optima Rack 1 3K ___...

Страница 6: ...power from batteries There is no dead time transition time is ZERO ms related to switching from normal mode to battery mode since load is always powered from inverter This is main characteristic of a...

Страница 7: ...ry charging level 0 25 26 50 51 75 y 76 100 Indicates battery failure Indicates low battery level Input Information Indicates input voltage input frequency and DC battery voltage Vac Input voltage Vdc...

Страница 8: ...ts To able or disable programmable outlets function 09 Programmable To configure timer value in minutes for programmable outlets USER MANUAL Optima Rack 1 3K __________________________________________...

Страница 9: ...as selected BATTERY MODE When AC input source is out of range Ups goes to battery mode to supply output from taking energy from batteries USER MANUAL Optima Rack 1 3K _________________________________...

Страница 10: ...push button is not been selected properly Push ON button during 2 seconds or longer 1 beep s alarm is active and LCD shows Input Line and Neutral are swapped Rotate UPS plug at wall socket to allow c...

Страница 11: ...th terms and conditions stipulated herein Transportation expenses are not covered by this limited warranty 3 Warranty is valid only if the original purchasing document issued to original purchaser by...

Страница 12: ...ries Step 2 Take out battery kit from UPS Step 3 Replace old batteries using equivalent batteries with same voltage and capacity in AH Follow instructions of 15 3 Step 4 Reconnect batteries assembly b...

Страница 13: ...apacidad 1100VA 800W 1700VA 1200W 2250VA 1600W 3400VA 2400W Range Rango Vac 100 load Model 120V 80Vac 150Vac Model 220V 160Vac 300Vac Range Rango Vac 50 load Model 120V 50Vac 150Vac Model 220V 110Vac...

Отзывы: