Electronic chart system
37
2-9-4 Hardware connection
Communication protocol: Please set the rate of output AIS to 38400 bits. It is
connected with the SARACOM, AIS SI-10,IO 30 feet (ground) and 31 feet (data) to
date output. If the AIS signal is no input,please reverse the polarity of feet 7,and feet
8.When properly connected, the three letters "AIS". Will be displayed
in the screen
above.
The definition of the eight core aviation plug data port IO as follows
1: 0183 output road
A + extremely
2: 0183 output road A -extremely
3: 0183 output road B + extremely
4: 0183 output road B -extremely
5: 0183 output road C + extremely
6: 0183 output road C -extremely
7: AIS input - extremely
8: AIS input + extremely
2-9-5 The AIS display settings
Please select
“
2:AIS display setting
”
to the
【
AIS vessels display settings
】
.Then you
can select and set it .