3
Part Number
18141, F, 11/06/2017
General Information
WARNING
GASOLINE FUME DETECTORS ARE MEANT TO SERVE AS A SUPPLEMENTAL WARNING SYSTEM. IT
IS NOT MEANT TO REPLACE STANDARD SAFETY PRACTICES WHICH SHOULD BE CARRIED OUT
AROUND EXPLOSIVE GASES.
The G-1BB-R, G-1CB-R, and G-2BB-R Gasoline Fume Detectors are an effective means to monitor
gasoline fumes in an engine compartments, leaking fuel tanks, or fumes from un-burnt
hydrocarbons emitted from faulty exhaust systems. In addition, these units automatically actuate
your bilge Blower to purge the space of fumes. The systems use sensors, located in a place of
interest, and a central display unit that notifies you of the state of the system.
Specification
System Specifications (G-1BB-R / G-1CB-R)
Operating Voltage: 9-30 VDC
Nominal Current Draw: 55mA @ 12 VDC
Maximum Current Draw: 95mA @ 9 VDC
Maximum Blower Output Current: 2A
Operating Temperature: -40°F (-40°C) to 185°F (85°C)
Alarm Horn: ≈ 68dB
System Specifications (G-2BB-R)
Operating Voltage: 9-30 VDC
Nominal Current Draw: 95mA @ 12 VDC
Maximum Current Draw: 150mA @ 9 VDC
Maximum Blower Output Current: 2A
Operating Temperature: -40°F (-40°C) to 185°F (85°C)
Alarm Horn: ≈ 68dB