XP3 PLC/HMI Hardware Manual
Page 28 of 42
LMAN007_R2V2
Set XP series
To open: Choose Menu
Tool
Set OP series; or choose
directly.
Method: This part includes two small parts (see the following diagram): OP Series Parameter OP
series Control.
OP Series Parameter
Master Screen ID: After the assigned project starts, display corresponding screen’s set
value. Usually defaulted No.1 screen as the master screen;
Password: To some projects which need to be protected, set password to manage the
operation of different user;
Screen Save: Set the screen protection modes. There are two modes: display screen
and turn off backlight. The user can set freely in the using process. If set “display
screen”, choose a defined screen as the screen protection, when time is reached. The
defaulted time is 3 minutes, if set to “never”, the backlight will stay on.
OP Series Control:
Select “Interactive Control” or “Peripheral Control”, these two items will display brightly, it means
they can be modified! Via modify register No., modify the corresponding register (If you choose
PLC type as XINJE XC series, the defaulted register number is D0.
Interactive Control: Includes “Auto Change Display Screen” and “Report Current Screen
Number”.
Auto Change Display Screen: This item corresponds with register D0. That is, if D0 is
changed in PLC the program, then the display screen will jump to D0 value’s screen
number. “Report Current Screen Number”, this item corresponding register D1, that is, if the
screen is refreshed, the value in D1 will refresh to the current screen number.
Peripheral Control: Includes “Analogue Input/Output” and “Use Data/Time Module”.
“Analogue Input/Output”: (According to the actual project requirement, defaulted one
module. I.e. 8 channels, each module takes 2 registers.), they correspond to a continual
register area from register D2 to register D17.