XIMEA xiQ Скачать руководство пользователя страница 3

xiQ e2v series quick start guide rev.20120416                              ©XIMEA 2012

LED 
indicators

Digital I/O
pinout

(rear panel view)

Dimensions

Optical

xi

Q

Isolated I/O 5-24V 20mA max.

GND

INPUT

OUTPUT

STATUS 1

xiQ013MG-E2

SN: 237198173

USB 3.0 SuperSpeed

STATUS 2

Based on the USB-IF’s USB 3.0 specification.

For use with XIMEA approved connection cables only.

POWER

ximea.com

STATUS 1

by default indicates pending exposure

LED indicators

function assignment configurable

via software

USB 3.0 micro

type B connector

18mm spacing M2 locking screws

Digital I/O

opto-isolated input and output

mating connector: 

Hirose P/N: SR38-4P-3P(71)

STATUS 2

by default indicates SuperSpeed link active

POWER

by default indicates camera power present

Digital Input

Opto-isolated input

 low (off) level 0-5V

high (on) level 12-24V

 max. input voltage 24V

Digital Output

Opto-isolated, NPN open collector,
max. load 25mA, max. open voltage 24V

GND

Common I/O ground

As  supplied,  xiQ  camera  is  configured  to  have  standard  C-mount  
1”x32TPI thread, back focal distance of 17.526mm There is no need to 
use additional adapters with  standard C-mount lenses. Given size of the 
sensor requires 1/2” sensor compatible lens to avoid vignetting.