![XIMEA xiC Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/ximea/xic/xic_technical-manual_3406218021.webp)
xiC - Technical Manual Version 1.16
21
3.4.
Optical path
3.4.1.
Filter glasses
A filter glass is part of the optical path of the camera. This glass is placed on a layer of silicone, to keep dust out of the camera,
but not glued. The conversion of C-mount to CS-mount (see section
) must be carried out carefully. Operating
the camera without a lens mount is not intended and can lead to dropping out of the filter glass and the entry of dust. Do not
use compressed air to clean the camera as this could push dust into the camera. Distance from the flange to sensor is designed
so the optical distance is 17.526mm - 0.2mm.
figure 3-3, Optical path section
3.4.2.
Monochrome and near infrared extended camera models
Used filter brand
BK7 AR2x
Thickness
1.0±0.1 mm
Coating
Anti-reflex both sides
table 3-4, monochrome camera - filter glass parameter
figure 3-4, monochrome camera - filter glass transmission curve
filter glass
sensor cover glass
sensor die
0
10
20
30
40
50
60
70
80
90
100
350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050
T
ransmit
tance
(%
)
Wavelength (nm)
BK7 AR2x - Transmission Curve