6. Re-install the computer casing.
7. Connect the power cord and turn on the computer.
WARNING! Do not power-on a passively cooled card without adequate forced airflow across the card
with proper air flow direction, otherwise the card can be damaged. This card can heat up after use in
the server. Use caution when handling. For more information, see Alveo U55C Data Center Accelerator
Cards Data Sheet (
8. To verify that the device has been installed correctly, enter the following linux command in
the terminal:
$ sudo lspci -vd 10ee:
If the card is successfully installed and found by the operating system, a message similar to
the following will be displayed. This is a sample output for an installed Alveo U55C card.
86:00.0 Processing accelerators: Xilinx Corporation Device 505c
Subsystem: Xilinx Corporation Device 000e
Physical Slot: 5
Flags: bus master, fast devsel, latency 0, NUMA node 1
Memory at d7ff2000000 (64-bit, prefetchable) [size=32M]
Memory at d7ff4040000 (64-bit, prefetchable) [size=256K]
Capabilities: [40] Power Management version 3
Capabilities: [60] MSI-X: Count=32 Masked-
Capabilities: [70] Express Endpoint, MSI 00
Capabilities: [100] Advanced Error Reporting
Capabilities: [1c0] #19
Capabilities: [e00] Access Control Services
Capabilities: [e10] #15
Capabilities: [e80] Vendor Specific Information: ID=0020 Rev=0 Len=010
Kernel driver in use: xclmgmt
Kernel modules: xclmgmt
Note: If this card has previously been installed, the
lspci
output will be similar to the one shown in
.
If you do not see a message similar to the previous one, see
Chapter 3: Card Installation Procedures
UG1468 (v1.0) November 23, 2021
Alveo U55C Data Center Accelerator Card Installation Guide
13