manualshive.com logo in svg
background image

7

All wired connections use a standard RJ45 Cat 5/6 (Ethernet) connection. XTouch controls can also be 
powered over Ethernet (Recommended). 
Xilica Designer and XTouch Applications can also be connected via a Wi-Fi connection, but this is not 
recommended.

Standard RJ45 cable

A) DHCP enabled router or server/router combination (Recommended)

With DHCP enabled routers and servers, the XTouch control will automatically obtain the IP address upon 
power up and connection.
It is recommended to use a router and PoE switch. This combo provides DHCP as well as power to the wall 
controls. Linksys routers and Netgear switches are recommended. 

B) Non-DHCP indirect connection (Non-DHCP PoE switches)

When XTouch controls are connected indirectly to the computer network via a switch and DHCP is not 
available to assign IP addresses, the connection process is not automatic. 

 

1. Single XTouch device (Non-DHCP) 

 

Once no DHCP is detected, the XTouch control will either try to connect using the IP address last 

 

assigned and stored on the device or attempt to revert to its default IP address of 169.254.64.64. 

 

Under some conditions, the processor may refuse to relinquish its stored IP addresses or revert to its  

 

default IP address  and thus refuse to connect.

 

 

2. Multiple XTouch controls (Non-DHCP)

 

For multiple mini controls connected to the network with no DHCP available, the user will have to 

 

manually assign unique IP addresses to each device. (Page 13-16)

XTouch:Device connection

Содержание XTouch Series: XTouch50

Страница 1: ...1 XTOUCH User Manual...

Страница 2: ...ding prong The wide blade or the third prongs are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 PROTECT T...

Страница 3: ...ilica Designer software a Windows installation 8 b Mac installation 9 Xilica Designer s Network View a Device network status 10 b Connection troubleshoot 11 12 c Manual assignment of IP addresses 13 1...

Страница 4: ...switch Ethernet cable Cat5 6 Getting Help Additional Help Files and video tutorials are available at our website www xilica com For further technical support please email support xilica com and we ll...

Страница 5: ...nal power supply not included If you are sending Power over Ethernet PoE the external power supply is not needed XTouch80 Ethernet connector Connect to the network using an Ethernet Cat 5 6 cable and...

Страница 6: ...wering on the Hardware This will allow for proper handling of IP address distribution to the Hardware The IP address assignment is automatic if connected to a DHCP enabled network A DHCP enabled route...

Страница 7: ...B Non DHCP indirect connection Non DHCP PoE switches When XTouch controls are connected indirectly to the computer network via a switch and DHCP is not available to assign IP addresses the connection...

Страница 8: ...k Install to continue 4 Allow the program to complete the installation process This may take a several minutes 5 When complete Windows will ask for permission to allow firewall access The suggested se...

Страница 9: ...download the latest version of the Xilica Designer software from the Xilica website www xilica com 2 Double click on the XilicaDesigner mpkg file saved on your computer 3 OSX will display an installat...

Страница 10: ...lays three colors red yellow and green Circled in Red Network Connection Indicators Green The device is Connected and operational Yellow The device is Connected and online but not operational Hovering...

Страница 11: ...lable the user will have to manually assign unique IP addresses to each device Please refer to Manual IP address assignment and Assigning a Static IP Address to your computer on Page 13 16 DHCP Connec...

Страница 12: ...Firmware Upgrade The pop up message shown will print out an error code Retry the Firmware Upgrade again Device can communicate to Xilica Designer with UDP but cannot communicate with TCP 1 Right click...

Страница 13: ...device settings The new IP address will display 2 In the Network tab select Change Network Configuration to disable DHCP and to insert IP addresses manually It also provides two built in test procedu...

Страница 14: ...of the screen and a menu will appear Select the gear icon This will enter the device settings 3 Deselect DHCP enabled 4 Type in the IP address Subnet mask and Gateway then click Ok to save 5 In Xilic...

Страница 15: ...P IPv4 then Properties to access the manual IP settings 5 Set up your computer s IP address to be 192 168 1 X where X can be any value from 0 255 but unique from other manually assigned device IP addr...

Страница 16: ...ings for your computers static address IP address 192 168 1 X X is any value from 0 255 but unique from other device IP addresses Subnet mask 255 255 255 0 Router 192 168 1 1 7 Click Ok and Apply to a...

Страница 17: ...view the current software version click on the About tab at the top of the software This window will display your current software version Matching the Firmware To assist you in determining which fir...

Страница 18: ...top left of each device 2 Save any design files from the device onto your computer All programmed data on the device will be erased during the upgrade process To save navigate to the File tab at the t...

Страница 19: ...grade can result in a complete corruption of the processor If this happens please follow the Xilica Designer Firmware Upgrade guide Note If more than one unit needs a firmware upgrade you can save tim...

Страница 20: ...A menu bar will appear at the bottom of the screen 2 Select the gear icon This will enter the device settings 3 You may change the language and display settings here To change network information des...

Страница 21: ...Advanced Settings to view more advanced device settings Click Ok to save your changes 5 To view the XTouch App version on the device swipe up on the screen Select the i icon to view the device informa...

Страница 22: ...series DSP is rather different from Solaro series DSP therefore the two DSPs cannot be used in the same project file For more information please visit the Xilica Designer section in the Xilica websit...

Страница 23: ...ine and operational Green indicator in Network View however the user can design a project in offline mode no devices connected and later go online when all devices are connected 2 Double click the XTo...

Страница 24: ...click the device that you would like to control Below a Neutrino A1616 N schematic is displayed The work area will adjust according to the Panel Size You may drag the corner of the window to adjust th...

Страница 25: ...rol by dragging a selection box around the desired parameters Or hold Cmd Click Mac Ctrl Click PC to select individual elements 6 Navigate back to your XTouch control window With the DSP parameters hi...

Страница 26: ...operty menu on the right Properties vary for different objects and modules 8 Simply add presets to the control screen easily by clicking and dragging them into the XTouch work area Please refer to Xil...

Страница 27: ...ing Elements from the Component Library menu to organize your screen This includes Labels Images Rectangles Lines and Eclispe Circles Customize Elements in the Object Property menu 9 Add Delete and Re...

Страница 28: ...oject Save your project by clicking the File tab at the top left of the software and Save Or save your project using the save icon at the top right of the software You may also upload an image for you...

Страница 29: ...cific device model from the drop down list Save project Save your project by clicking the File tab at the top left of the software and Save Or save your project using the save icon at the top right of...

Страница 30: ...work area is now a solid color This indicates that you are in online mode Also the previous Load Design to Device s button has now changed Switch to Design Mode Switching from Online mode to Design mo...

Страница 31: ...xilica com and we ll connect you with a solutions engineer Alterna tively if you d like to speak to someone you can call the following numbers for immediate assistance International 1 905 770 0055 US...

Отзывы: