processor model must match the Uno software module and the Uno app processor version being 
used in the NeuConsole software. 

7.  Initial Device Connectivity:  

The Uno series of digital processors run on a network based infrastructure and are configured 
and controlled by a host computer via Ethernet using the NeuConsole software. 
A network connection can be made between your computer and Uno via 

(A)

 A DHCP enabled 

Router, Server, or Router/ Server/Switch/POE Switch combination as recommended and shown 
below or 

(B)

 A Non-DHCP enabled Direct connection or Indirectly via an Ethernet switch. 

 
The primary difference between these two connection methods is the automatic IP address 
assignment / management the DHCP provides in 

(A). 

 

(A)  DHCP Enabled Router, Server, or Router/Server/Switch Combo Connection

   

                             

  The Uno processor device boots up with DHCP enabled by default so with DHCP enabled 

routers and servers Uno will automatically obtain an IP address upon connection and power 
up.  This may take a minute or two as the devices look for DHCP to obtain their IP address. 

 

Available DHCP is the recommended connection method

.  Where our NeuPanel Series 

wall controls will be used to remotely control the processor we recommend the use of a low 
cost router along with a POE switch.  This combo will provide DHCP as well as power to the 
wall controls over their Ethernet cable by way of the switches POE feature (Power Over 
Ethernet).                                                                                                                                

Note:

  Linksys routers/NetGear switches have tested well (D-Link routers have not). 

 

(B)  Non-DHCP Enabled Direct or Indirect Connection 

When the processor is connected directly to a computer or indirectly via a switch or hub and 
DHCP is not available to assign IP addresses - the connection process is not automatic.   

(1) 

 

A Single Processor or Device in the Network Only - No DHCP Available 

Once no DHCP is detected - a single direct or indirectly connected processor/device will 
either try to connect using the IP address last assigned and stored in the device or 
attempt to revert to is default IP address of 169.254.128.128.  Under some conditions the 
processor/device might refuse to relinquish its stored IP address or revert to its default IP 
address and thus refuse to connect.  

To simplify and speed this non-DHCP enabled 

connection we recommend

 - that before you power up your processor/device you 

should 

Reset

 the processor/device to its 

Default IP Address

 using the 

IP Reset Button

 

on the rear of the device.  Resetting the processor to its default IP address of 
169.254.128.128 will have you connecting directly quickly and without problems when no 
DHCP is available.   

Содержание uno series

Страница 1: ...UNO Product Quick Start Guide ...

Страница 2: ...g prong The wide blade or the third prongs are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 PROTECT THE POWER CORD FROM BEING WALKED ON OR PINCHED PARTICULARLY AT PLUGS CONVENIENCE RECEPTACLES AND THE POINT WHERE THEY EXIT FROM THE APPARATUS 11 ONLY USE ATTACHMENTS ACCESSORIES SPECIFIED BY THE MANUFACTU...

Страница 3: ...et interface Ethernet cable Cat5 or 6 3 Getting Help The included NeuConsole software the Windows software that controls the Uno processing and hardware includes a Help File That help file provides a detailed User Manual software and hardware as well as this Quick Start Guide If you d like to contact us regarding product support or technical designs email support xilica com and we ll connect you w...

Страница 4: ...p Uno U1616 Bottom Uno U1616 N w network audio RJ 45 connectors 1 Power On Off Switch 2 Fuse Compartment Should you need to replace the fuse use a T Series 2 5A 250v fuse Ensure power to the device is disconnected when replacing the fuse 3 Power Input Connector Insert the IEC plug connector end of the supplied cable into the rear panel of the Uno Connect the AC end of the cord into an AC power sou...

Страница 5: ...cation you loaded the software from previously or what the source was USB Internet etc Make sure the NeuConsole Software version is the latest version see About menu vs the web site Make sure the processors Firmware version is compatible with software view device firmware version in Network View See information on Page 4 6 and Page 11 15 to assist If you have a personal Firewall setup on your comp...

Страница 6: ...processor we recommend the use of a low cost router along with a POE switch This combo will provide DHCP as well as power to the wall controls over their Ethernet cable by way of the switches POE feature Power Over Ethernet Note Linksys routers NetGear switches have tested well D Link routers have not B Non DHCP Enabled Direct or Indirect Connection When the processor is connected directly to a co...

Страница 7: ...ent IP Reset switch that was hidden behind a removable cover on the rear of the processor If yours is like that Remove the small black cover on the rear of the processor near the Ethernet connector remove 2 small screws Looking from the back of the processor you will see a small black Reset Switch to the right of the Ethernet connector Press this Reset Switch forward lightly with your finger and w...

Страница 8: ...n located at the top right of the Project View Design Mode work area page 10 Network View and Connection a Click Start Network View from the NeuConsole Startup window The Network View displays all processor and control devices connected to the network plus information such as the processor device model a green yellow or red network connection indicator the IP address and the devices Firmware versi...

Страница 9: ...ellow connection indicator is the result of 1 A non DHCP connection where multiple processors are in use and each device needs a unique IP address manually assigned to it 2 Where a non DHCP direct or indirectly connected single processor device is not reverting to its default IP address and or is holding onto its previous address and 3 Software Firmware incompatibility b Solutions 1 See instructio...

Страница 10: ... required for each processor or device Each processor or device indirectly connected to the PC via a network switch or hub Note Make sure your computer is set to Obtain IP Address Automatically We will set your computer s static IP Address after changing the IP Addresses on all the processors and devices first To manually assign static IP addresses to multiple processors and devices a Connect devi...

Страница 11: ...g settings for your PC s unique static address IP Address 192 168 1 X Example IP might be 192 168 1 185 based on my Subnet Mask 255 255 255 0 unique device addresses above Gateway 192 168 1 1 DNS Servers 192 168 1 1 g If you set up your devices as per step 13 on Page 9 10 above you will now see them appear online and connected in Network View in the NeuConsole software 15 Firmware Upgrade to Proce...

Страница 12: ...e from the NeuConsole Startup window as shown on the left you can select New Design Project in order to begin a new DSP design project Project View Design Mode Work Area Either will open the Project View Design Mode work area page as shown below and as identified by the white dotted alignment work area See the Project Design Mode and the red Switch to Online Mode headings buttons at the top left a...

Страница 13: ...n and this DSP design project onto the white work area For our example we chose the Uno U0808 You will notice that the Uno U0808 processor module placed in the project view design mode work area is a light see through red color Map Physical Device a With the red Uno U0808 processor module for this application placed in the Project View Design Mode work area as shown above and when the processor de...

Страница 14: ...port Device Design from File as shown below left 2 That will take you to the folder where you saved your pre designed Uno Apps early on in this quick start guide or you can browse to the file where you saved them Uno Apps are sxml files New Project Saved DSP design projects are pjxml files Open Project 3 Select the pre designed Uno App device design sxml file you want to use for this New Design Pr...

Страница 15: ... See the Print Project to JPEG File printer symbol button to the right of the Zoom slider at the top right 6 Once the Component Libraries menu on the left is not required it can be minimized to provide more space to arrange items The Component Properties menu on the right can remain open until you label all your wired I O Source and Destination connections described on Page 15 17 Then it too can b...

Страница 16: ...he top or bottom right of any fader style control to increase or decrease its level in fine adjustments Rotary Style Level Controls point and click the tab on the left and right side of the rotary control where the pop up Step Up or Step Up appears to increase or decrease level in fine adjustment Exact Adjustment Click to highlight a numeric level and type in the specific numeric level value 17 La...

Страница 17: ...design project parameter adjustments are completed and saved to your PC you can transfer save your work to the connected physical processor device To do this a Click the red Switch to Online Mode button at the top of the Project View Design Mode work area page as shown below only visible when connected to a processor b This button selection actually performs two functions at the same time it trans...

Страница 18: ...is where you open or access previously worked on and saved DSP design project files as compared to creating a New Design Project as we did in this guide above In both cases the saved DSP design project file once opened will appear in your Project View Design Mode work area along with the specific Uno processor module used in the saved design project Double click the processor module in the work ar...

Страница 19: ...s a reference only of setting changes made to the processor in Open Device mode You must be working with that exact specific DSP design project file as saved on your PC and working in Design Mode and Online Mode in order for the parameter changes you made to the physical processor device while in Open Device mode to be accessible and savable to the project file and there are safety reminders and p...

Страница 20: ...l that can be viewed in the NeuConsole software Help File information saved on the USB drive packaged with each processor this Quick Start Guide can be found in both locations as well our website Product Tutorials or contact Xilica via our website or this guide s contact info ...

Страница 21: ...support xilica com and we ll connect you with a solutions engineer Alterna tively if you d like to speak to someone you can call the following numbers for immediate assistance North America Rest of World 1 905 770 0055 Europe 31 29940 1100 China Hong Kong SAR 852 2604 9382 www xilica com Version 1 0 ...

Отзывы: