Functions of Panel Keys and Switching   

Button 

First function (short press, cycle) 

Second function (FUNC+) 

Long press  

PRE/ATT 

PRE - ATT - direction connection   

CMP/F-L 

Turn it on to transmit voice compression 

Digital filter F-L, low-pass cutoff frequency 

selection 

Reset 

parameters 

NB/F-H 

NB SW-NB Level-NB Width 

Digital filter F-H, high-pass startup 

frequency selection 

Reset 

parameters 

AGC/SPL 

Open AGC, F-S+A close and circulating   

Turn on the pilot frequency transceiver 

operation mode 

RF GAIN 

VM. 

Switch frequency mode or channel mode 

Call Sign 

Editor 

MW/MC 

Turn on channel memory function 

Channel clearing   

A/B.A>B 

Switch between VFO-A and VFO-B 

Copy the current VFO to the background 

VFO 

TUNE 

Turn on/off the antenna tuning function 

Antenna 

tuning 

POW 

POWER 

Transmitting Power Setting 

MICGAIN 

Hand microphone MIC 

gain setting 

Standing-wave 

scanning 

SWR THR 

Standing-wave protection 

threshold setting   

INPUT 

Voice input mode selection 

KEY 

SPEED 

Automatic key rate setting 

CW Volum 

Side tone volume setting 

CW automatic 

decoding 

M/L/R 

Manual/automatic left and right 

mode switching 

CW TONE 

Side tone frequency setting 

MODE 

iambic A/B mode switching 

QSK 

Insert/non-insert selection 

QSK Time 

Insertion time setting 

Ratio 

Setting of automatic key 

dot-and-dash interval 

proportion 

LOCK 

SCALE 

Spectrum reference level 

setting 

Lock button 

AVE FFT 

Mean value setting, ranged 

1~10 

Volume knob  Loudspeaker / earphone switching   

VOX ON/OFF  Voice control switch   

VOX GAIN 

Voice control gain setting 

ANTI-VOX 

Hand microphone and 

speaker echo suppression 

setting 

VOX DLY 

Voice control transmission 

turnoff delay 

Multi-knob 

Filter center mode setting   

Filter bandwidth mode setting   

Main knob    Frequency step selection 

Open RIT  

The operation of the second function: 

  Press the [FUNC] key first, then the F indicator will be on, then press the 

corresponding function key. 

  Press the [FUNC] key again to exit the second function. At this time, the F 

indicator is off. 

  In any function (including FUNC second function) setting interface, short 

press the main knob to save, exit the function setting and return to the main 

interface. 
 

 

12 

Содержание G90S

Страница 1: ...ection and adjustment are no longer problems High performance RF front end SSB CW AM three working modes 1 8 inch high color TFT LCD 24k bandwidth spectrum display waterfall display Software defined n...

Страница 2: ...e of working temperature 0 C 50 C Frequency stability 1 5ppm in the 10 60min after startup 25 C 1ppm hour Power supply voltage 10 5 16 5VDC negative electrode grounding Current consumption Receiving 7...

Страница 3: ...z 0 35uV 10uV 2 0 27 9999MHz 0 25uV 2uV 28 0 30 0MHz 0 25uV 2uV PRE on ATT off NB off NR off SSB CW AM 10dB S N Mirroring suppression 70dB Midband suppression 60dB Audio output 0 5W 8 10 THD Audio out...

Страница 4: ...ad fixing stud 2 nos Hexagon wrench 1 in number Power line 1 in number Warranty card 1 in number Instructions 1 in number Quality certificate 1 in number Optional components CE19 host ACC adapter can...

Страница 5: ...nector of the telegraph key is a 6 5mm 2 core plug please change it to a 3 core 3 5mm stereo plug according to the wiring method shown in the figure above and connect the trigger end of the electric k...

Страница 6: ...4 Multi function Adjustment Knob By default turning this knob will step at 100kHz Long press this knob to switch to the Select Custom function 5 6 MODE mode switching Mode switching It will switch cyc...

Страница 7: ...Panel Keys 12 Function keys The key definitions and functions are detailed in the operation section Page 12 7...

Страница 8: ...port It is a 3 5mm interface 3 wires used for IQ signal output 17 ACC interface The interface is an 8 core mini type DIN interface See the interface definition for details See Page 5 for the definitio...

Страница 9: ...ires interface used to connect earphones See Page 5 for the wiring method 22 Communication interface located on the left side It is used for hardware updating of head unit and the on line control with...

Страница 10: ...one operation indicator light 5 Figure key area Figure keyboard area 6 FIL key Filter selection 7 MODE key Selection of working mode of host 8 Functional indicator light No 9 Function keys F1 F2 key u...

Страница 11: ...ply and black line shall be connected with negative pole of power supply EMC magnet ring can be applied on power lines to prevent external disturbance from entering radio via power lines and radio fre...

Страница 12: ...ic key rate setting CW Volum Side tone volume setting CW automatic decoding M L R Manual automatic left and right mode switching CW TONE Side tone frequency setting MODE iambic A B mode switching QSK...

Страница 13: ...ncy receiving transmitting mode is open loudspeaker mode Short press the volume key to switch to the earphone mode and here displays the earphone icon key lock sign under receiving status S refers to...

Страница 14: ...key to turn off the screen display When the screen is turned off the host is still in normal working condition Pressing any key or turning the knob will turn up the screen display Display of Power Vol...

Страница 15: ...witched the custom band passes This function can be opened or closed as detailed in Item 8 of the system menu 60m frequency band shall be opened according to regulations of the country or region Frequ...

Страница 16: ...ter the text editor 2 The bottom of the screen is the character selection area Rotate the main knob to select the desired character Press the main knob in a short time to select the character 3 Press...

Страница 17: ...ncy setting state and cursor will be flickering at the first place on the left of frequency display position Input expected frequency values one by one and press F INP ENT key again to complete the fr...

Страница 18: ...audio switch without signal so that the speaker can be muted Operation methods 1 Long press Multi function Adjustment Knob to enter the user defined function menu rotate the main knob to select the S...

Страница 19: ...VFOA B Settings G90S transceiver has two built in independent VFOs which can respectively set differ tent frequencies and modes Cooperated with SPL function it can conveniently achieve pilot frequenc...

Страница 20: ...me enable disable or select different AGC modes and circulate them in the following order AGC S AGC F AGC A AGC AGC S Slow AGC control Recommended settings AM mode AGC S AGC F Fast AGC control SSB CW...

Страница 21: ...can be in the shoot through state which is conducive to strengthen the front end performance of the receiver and reduce the influence of interference signals When the S meter displays that the receive...

Страница 22: ...nary times is recommended Voice Compression CMP The voice compression can increase the average power output during the voice communication so that signals can be resonant 1 Press CMP key at the bottom...

Страница 23: ...ation about the telegraph text after decoding will appear at the bottom of the screen Since the accuracy of CW automatic decoding is related to the reporting accuracy signal propagation quality and fr...

Страница 24: ...y low magnitude on both sides of voice spectral lines displayed on the screen the hand microphone voice gain value can be appropriately adjusted till superfluous spectral lines disappear Voice control...

Страница 25: ...used and the internal antenna tuning is started for tuning strong radio frequency interference may be caused to the unit or electronic equipment Standing wave Scanner SWR The G90S host has the antenn...

Страница 26: ...utput In the system menu select AUX OUT VOLUM to set the appropriate output volume When the digital communication is conducted and the ACC port is used for audio input it shall be ensured that the vol...

Страница 27: ...he VM key on the panel in a short time to enter channel mode 2 Rotate the main knob to switch the current channel Clear the channel memory 1 In channel mode press the combination key FUNC MW MC at thi...

Страница 28: ...meters Adjustment of the starting and cutoff frequencies of the filter 1 Press FUNC key in a short time to enable the operation of the second function 2 Respectively press CMP F L key and NB F H key a...

Страница 29: ...er the SCALE reference level setting 2 Rotate the main knob to adjust the SCALE value till the display effect is appropriate 3 Press the main knob in a short time save and exit the setting interface T...

Страница 30: ...ger The yellow exclamation point indicates that the equipment installation is abnormal A set of CE 19 expansion card optional Several EMC magnetic rings self provided Connection steps 1 Insert the 3 5...

Страница 31: ...put signal terminal of the radio The audio cable is connected as follows AF_OUT Audio input accessing to the computer AF_IN Audio output accessing to the computer 8 core ACC connecting line Insert int...

Страница 32: ...XPA125B Moreover the ALC control will be built between two machines When the G90S output power exceeds the power limit of the XPA125B the AACL control will automatically decrease the output power of t...

Страница 33: ...key function setting 3 Handle F2 Hand microphone F2 key function setting 4 LCDBL Screen backlight brightness setting 5 AUX IN Volum ACC port input audio volume setting 6 AUX OUT Volum ACC port output...

Страница 34: ...alue PRE ATT SPLT NB COMP AGC Default PRE ATT Menu item 3 Handle F2 Function Customize the function of F2 key on multi purpose hand microphone Optional value PRE ATT SPLT NB COMP AGC Default SPLT Menu...

Страница 35: ...you think that signal tone you hear is 20Hz above the correct frequency set this item at 20Hz Menu item 8 Band Stack Mode Function Set band stack During the switch of frequency band enable cancel the...

Страница 36: ...function enables the restoration of factory settings Operation methods 1 Hold the FNUC key to start up and enter the restoration of factory settings 2 Press PRE key to confirm the implementation Pres...

Страница 37: ...TERFACE V REFERENCE MANUAL Wave Band Voltage Data The ACC socket of the BAND terminal of G90S outputs the band voltage of each frequency band This band voltage is associated with the current frequency...

Страница 38: ...Copyright Statement All Rights Reserved 2019 Chongqing Xiegu Technology Co Ltd reserves all rights of the manual All parts of the manual shall not be copied without permission 1010160204 C 38...

Страница 39: ...an radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interferen...

Отзывы: