background image

25

Step 3

Software Home Page

Содержание DDL-M1

Страница 1: ...DDL M1 Intelligent Microscope Operating Instruction V1 0 ...

Страница 2: ......

Страница 3: ...roscope Monomer Introduction 7 How to Use the Microscope 9 Microscope Base Introduction 11 How to Use the Microscope Base 13 Accessories and tools 16 APP Usage Guide 16 How to Use on Android iOS 17 How to Use on PC 19 For Windows 19 For MAC 22 Microscope Trouble Shooting 26 Product Performance failure table 28 Storage Environment 29 Operating Environment 29 ...

Страница 4: ...oid dust or foreign matter This microscope can be used by hand or can be inserted into the base as a table Pay attention to the strength of the insertion to avoid damaging the components When placing the specimen please pay attention to the position and place it as far as possible in the center of the lens right below Avoid having a bad experience with blurred objects ...

Страница 5: ...4 Product Introduction 偕 Microscope Installation Instructions Microscope Structure Microscope monomer Microscope base ...

Страница 6: ... Step 2 Hand strap facing the rear the rear microscope monomer lens slot should be aligned with the mounting hole Step 3 Holding the base with one hand Step 4 Insert it to the bottom insert the microscope monomer vertically focus wheel is all exposed down into the mounting hole ...

Страница 7: ...ndicator goes off when full During charging if there is slight heat in the microscope shell and battery please rest assured that it is normal When the microscope base is low battery the power indicator light flashes red The red light is always on when charging and the great light is always on when full You can charge device by your daily phone charger computer or power bank Charging time should no...

Страница 8: ...t Notice There are two magnifications to rotate the focus wheel at the same distance Lifting knob on the base and magnification minification button can also be adjusted for multiple when adjusted the focus wheel lifting knob and magnification minification button together the maximum magnification is 400 times ...

Страница 9: ...oscope has been turned on Press for 3s again when the light goes out means the microscope has been turned off Power WiFi connection indicator When the battery is low the blue light flashes quickly When charging the red light is always on The blue light is always on when WiFi is successfully connected and the blue light flashes when WiFi is not connected ...

Страница 10: ...ct the microscope and mobile app via WiFi Remove the lens cover Hold the upper part of the microscope with one hand the tip of the finger can be put into the hand strap to avoid falling Turn on the microscope by pressing the power button ...

Страница 11: ...gn the lens of the microscope at the object to be observed Rotate the focus wheel with the other hand and observe the display of the phone At this time you can adjust the focus wheel to the best viewing ratio ...

Страница 12: ...tion window will light up which means the microscope base has been opened Turn the light brightness knob counterclockwise and hear a click the observation window will go out which means the microscope base has been closed Note After the microscope base is closed be sure to close the microscope monomer and cover the lens cover at the same time ...

Страница 13: ...nces Observation Window Introduction The observation panel should be cleaned regularly to avoid oil stains which may affect the observation experience Light adjustment function description of observation window The intensity and weakening of the light will have different effects on the outline and details of the specimen Please pay attention to the adjustment and use Different colors of lights can...

Страница 14: ...13 ߗ How to Use the Microscope Base Place the microscope on a stable table and avoid shaking or falling Turn on the microscope monomer and base ...

Страница 15: ...14 Connect the microscope and mobile app via WiFi Adjust the microscope lifting knob so that the microscope monomer is at a appropriate height easy to place the object of observation ...

Страница 16: ...servation panel Be sure to make the side with the cover glass face up and don t put it upside down Rotate the focus wheel and observe the display of the phone At this time you can slowly adjust to the best observation magnification Adjust the observation height and focal length to achieve other multiple observations ...

Страница 17: ...16 ߘ Accessories and tools Notice If you purchased the simple version the accessories only contains 5 biologic section specimens 5 blank slides data cable and 2 specimen fixation clip ...

Страница 18: ...lay version international user or Android China version Chinese user download and install it or input the following URL in the browser download and install it IOS Android downloading QR code Or enter the following address in your browser to download it https active clewm net DuKSYX qrurl http 3A 2F 2Fqr09 cn 2FDuKSYX gtype 1 key bbb57156739726d3828762d3954299ca7a957b6172 http static new dangdangli...

Страница 19: ...blue indicator light is flashing which means the device is turned on Step 3 Connect the microscope to IOS Android device Open the smartphone s WiFi setting find the name of WiFi wifi_camera_wifi30_xxxx click to connect then run APP you will see the main interface at this APP ...

Страница 20: ...Cam com click the third link and download the software then click the Next stepĺReceiveĺInstallĺFinish Notice If you were Win10 system this software is not necessary you can directly search Camera in Windows for find it and click on For other system please download the corresponding app ...

Страница 21: ...pp Step 3 Connect the device with PC via USB cable then long press Power button 3s to turn on the device Notice do not turn on the device before connect or you won t be able to see the picture if you turn on before connect that means opened the WiFi connect with smartphone ...

Страница 22: ...21 Step 4 Click Devices in menu bar then click USB CAMERA to select the microscope equipment name ...

Страница 23: ...22 For MAC Step 1 Download Software Please login https soft hvSCam com please select the HiViewSetup1 4 for mac Then download the software as shown in the figure ...

Страница 24: ... 2 Double click and open HiView The following information will appear Then click next step Connect your microscope to a mac computer or laptop via the USB cable Then open the softwareˈ If there are safety tips ...

Страница 25: ...ollows System Preference Open the Security Privacy select General and AppStore and identified developers Select Open Anyway The opening interface of software is as shown in the figure Allow HiView below to access your camera ...

Страница 26: ...25 Step 3 Software Home Page ...

Страница 27: ...ipment is out of power ĹThe equipment failure ķRepeat connection at close range ĸCharge the device ĹTurn off the APP and restart the device before using it ĺSend for repair The device cannot be charged ķThe charging interface is not firmly inserted ĸNo power access ĹThe equipment failure ķPlug interface again ĸPlug in ĹSend for repair The device is not working properly Internal damage caused by wa...

Страница 28: ...erature to stabilize use it after the fog disappears for a period of time Specimens were observed with foreign bodies and were not observed clearly The specimen surface is dirty and the observation panel is dirty Wipe the specimen surface and observe the surface of the panel The shell is broken and cracked due to falling and impact Damage caused by external use Man made damage is not covered by th...

Страница 29: ...with APP Unable to charge properly Microscope base The base can t turn on Unable to charge properly The illuminating dimming button doesn t work properly Notice The product accessories user interface and other illustrations in the manual are schematic diagrams for reference only Due to the update and upgrade of the product there may be some differences between the actual product and the schematic ...

Страница 30: ...perating Environment Notice At low temperature the available capacity of the battery will be reduced to varying degrees Please use the device at a temperature of 10 45 Please prevent the device from getting wet with water beverages or corrosive liquids Please keep the device away from heat source open flame flammable and explosive gas liquid Please avoid dust entering the device lens and inside Pl...

Страница 31: ......

Страница 32: ......

Страница 33: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the eq...

Отзывы: