background image

|

www.flexible-mediaserver.com

FM4 MAX  /  Operating Manual  /  Q2.23

10

Backup

We differentiate between the following:

FM4 Factory Defaults

•  The Factory Defaults are an image backup of the system drives initial delivery state. It has been created by our 

technicians shortly before shipping the unit and is stored on a fast USB 3.1 stick supplied with your flexible 

mediaserver FM4.

• 

Use the USB stick to revert to factory defaults if need be. (See section “Reset to Factory Defaults” for details)

Backup or Data-Backup

• 

A Backup or Data-Backup is a copy of your data on a different storage unit which ideally is taken to a different 

location for safety. As we do not have your data at delivery, your data will need to be backed up by you or your 

client.

• 

There are a variety of backup software solutions on the market. We do not offer additional backup solutions 

as a part of our flexible mediaservers.

 

We recommend creating additional image backups of the final installation state of your FM4 when ready to be 

handed over to your client or when being installed in your venue.

 

We also recommend to regularly backup your data to physically separate media stored at another location 

to protect your data against theft, fire or water damage, lightning strikes or sudden voltage peaks, viruses, 

unintentional data deletion etc.

 

Any installed RAID array within your FM4 does NOT replace a real backup of crucial data.

 

XI-MACHINES is not responsible for any data loss after hardware or software crashes.

Reset to Factory Defaults

If the media server installation no longer works properly or a software or driver installation, system setting or 

similar has led to failures of the operating system, there is always the option of resetting the entire installation to 

our delivery status/factory defaults.

 

We recommend to always contact our support prior to doing so, to make sure a reset is really necessary and 

the problem can’t be solved in any other way. Remember, a reset means that all additionally installed files 

and software are deleted from the system drive and all settings made to the installation are reset to factory 

default.

If our support recommends your flexible mediaserver FM4 to be reset, our technicians will guide you through the 

process. Alternatively you may also refer to the „FM4 Factory Reset Guide“, located in the following location: “C:\

XI-MACHINES Support\”.

 

Always keep in mind that a reset to factory defaults can only be done if the system drive is still functioning. 

If a hardware error has occurred, your mediaserver cannot be reset or restored! In this case, our technical 

support will recommend an appropriate course of action.

Содержание FM4 MAX

Страница 1: ...OPERATING MANUAL flexible mediaserver FM4 MAX...

Страница 2: ...FM4 MAX Operating Manual Q2 23...

Страница 3: ...Storage Setup 7 Redundant Power Supply 8 Expansion Options 8 Installing additional Hardware 8 Driver Updates 9 Operating System Updates 9 Backup 10 Reset to Factory Defaults 10 Cable Route Display Ada...

Страница 4: ...FM4 MAX Operating Manual Q2 23...

Страница 5: ...nd or poorly ventilated place which could affect its operation or the operation of other closely located components Do not install near any heat sources such as radiators stoves or other apparatus inc...

Страница 6: ......

Страница 7: ...a fully configured turnkey solution including software licenses for the media server software of your choice with an option to exclude licenses if needed This ensures maximum compatibility optimal pe...

Страница 8: ...etwork activity of the two integrated 10Gbit sec Ethernet ports of your FM4 MAX flashing is normal 5 Error LED Lights up in case of system error such as overheat fan fail or similar If the LED is lit...

Страница 9: ...s to connect serial devices to your FM4 9 Pin RS 232 COM connector 11 WiFi Antenna Connectors Use these to connect your FM4 MAX to wireless networks WiFi antennas included 12 1Gbit sec Network Ports U...

Страница 10: ...applications the corresponding software is pre installed configured and optimized and the required license is included and activated In addition a multi boot environment has been set up for you allowi...

Страница 11: ...isplays into a larger virtual canvas Synchronize your displays using frame sync or genlock technology Load and unload EDID information If you need assistance in understanding the Nvidia Control Panel...

Страница 12: ...e failure of the power supply hardware itself but also against the failure of the actual power source Expansion Options Your FM4 MAX offers remarkable expansion capabilities In addition to the four pr...

Страница 13: ...tem Updates The operating system installation of your flexible mediaserver FM4 has been set to a fixed update status validated by our specialists To avoid possible errors and malfunctions we do not re...

Страница 14: ...ter damage lightning strikes or sudden voltage peaks viruses unintentional data deletion etc Any installed RAID array within your FM4 does NOT replace a real backup of crucial data XI MACHINES is not...

Страница 15: ...ged if handled carelessly Using DisplayPort DisplayPort is a standard with lower operating voltages compared to HDMI and therefore can only be used for up to 5 meters 16 4 feet of effective cable leng...

Страница 16: ...Allen screws back in place IMPORTANT Do not use compressed air or vacuum cleaners for cleaning inside the mediaserver If you do this the installed fans will start to spin fast causing dynamo like pow...

Страница 17: ...operator error Repairs or improper maintenance performed by the customer or a third party without the authorization of XI MACHINES Product failure caused by interruption to the electrical supply curr...

Страница 18: ...orts 2x 10Gbit sec Ethernet 1x 1Gbit sec Ethernet 1x 1Gbit sec Ethernet dedicated Management Port WiFi Integrated WiFi Module WiFi 6E 80211ax Bluetooth Integrated Bluetooth Module BT 5 3 Peripheral US...

Страница 19: ...hip optimized Yes Hardware Security Yes TPM 2 0 Remote Management Yes dedicated Management Port Illuminated Power Switch Yes Integrated Rear LED lighting Yes 2 Brightness Levels Integrated Rear Strain...

Страница 20: ...a Decibel Range 0 100 dB Ln based on LAFmax_dt k1 Measurement Distance 100cm Tested Device XI MACHINES exible mediaserver FM4 MAX Device Configuration FM4 MAX base configuration 24 Core CPU 64 GB Syst...

Страница 21: ...l Range 0 100 dB Ln based on LAFmax_dt k1 Measurement Distance 100cm Tested Device XI MACHINES exible mediaserver FM4 MAX Device Configuration FM4 MAX base configuration 24 Core CPU 64 GB System Memor...

Страница 22: ...O FM4 MAX exible mediaserver FM4 brand name type or model product description to which this declaration relates is in conformity with the following harmonized standards Safety EN 60950 1 2006 A11 2009...

Страница 23: ...this declaration relates is in conformity with the following harmonized standards FCC Part 15 Subpart B Class A Operation is subject to the following two conditions 1 this device may not cause harmful...

Страница 24: ...es are trademarks registered trademarks or trade names of their respective holders All technical specifications in this document are subject to change without further notice XI MACHINES GmbH Lokstedte...

Отзывы: