Component

Specifications

Storage

Supports a variety of drive configurations. For details,
see 

5.5.1 Drive Configurations

.

● Supports two M.2 SSDs.

– M.2 SSDs are supported for RAID 0/1 and hot

swap without opening the chassis cover is
supported when the server is configured with an
Avago SAS3004iMR RAID controller card.

– The drive letter of the M.2 SSDs managed by the

Avago SAS3004iMR RAID controller card can be
set to 

sda

 by modifying the GRUB parameters only

when the RAID controller card is used with a
SmartRAID 3152-8i or SmartHBA 2100-8i RAID
controller card.

NOTE

● The M.2 SSD module is used only as the boot device

when the OS is installed. Small-capacity (32 GB or 64
GB) M.2 SSDs do not support logging due to poor
endurance. If a small-capacity M.2 SSD is used as the
boot device, a dedicated log drive or log server is
required for logging. For example, you can dump VMware
logs in either of the following ways:
● Redirect 

/scratch

. For details, see 

https://

kb.vmware.com/s/article/1033696

.

● Configure syslog. For details, see 

https://

kb.vmware.com/s/article/2003322

.

● The M.2 SSD cannot be used to store data due to poor

endurance. In write-intensive applications, the M.2 SSD
will wear out in a short time.
Use enterprise-level high endurance (HE) SSDs or HDDs
for data storage.

● The M.2 SSD is not recommended for write-intensive

service software due to poor endurance.

● Do not use the M.2 SSD as the cache.

● Supports hot swap of SAS/SATA drives.
● Supports hot swap of SAS/SATA/NVMe U.2 drives.

NOTE

The NVMe drives support:
● Surprise hot swap if the VMD function is enabled and the

latest Intel VMD driver is installed.

● Orderly hot swap if the VMD function is disabled.

● Supports a variety of RAID controller cards. Use the

Compatibility Checker

 to obtain information about

the specific RAID controller cards supported.
– The RAID controller card supports RAID

configuration, RAID level migration, and drive
roaming.

– The PCIe RAID controller card occupies one

standard PCIe slot.

FusionServer 2488 V5 Server
Technical White Paper

6 Product Specifications

Issue 06 (2023-12-12)

Copyright © xFusion Digital Technologies Co., Ltd.

47

Содержание FusionServer 2488 V5

Страница 1: ...FusionServer 2488 V5 Server Technical White Paper Issue 06 Date 2023 12 12 xFusion Digital Technologies Co Ltd...

Страница 2: ...se of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this docu...

Страница 3: ...risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially haz...

Страница 4: ...gure that shows how to measure dimensions Updated 6 1 Technical Specifications and claimed support for U 2 drives Updated CE UKCA and CCC certification standards in 10 Certifications Added A 1 Chassis...

Страница 5: ...4 Memory 20 5 4 1 1 Memory Identifier 20 5 4 1 2 Memory Subsystem Architecture 21 5 4 1 3 Memory Compatibility 23 5 4 1 4 DIMM Installation Rules 24 5 4 1 5 Memory Installation Positions 25 5 4 1 6 Me...

Страница 6: ...55 8 1 Security 55 8 2 Maintenance and Warranty 58 9 System Management 59 10 Certifications 61 11 Waste Product Recycling 63 A Appendix 64 A 1 Chassis Label 64 A 1 1 On the Front Top 64 A 1 1 1 Namep...

Страница 7: ...82 C Acronyms and Abbreviations 83 C 1 A E 83 C 2 F J 84 C 3 K O 86 C 4 P T 86 C 5 U Z 88 FusionServer 2488 V5 Server Technical White Paper Contents Issue 06 2023 12 12 Copyright xFusion Digital Tech...

Страница 8: ...ation and in memory computing The 2488 V5 is a secure highly expandable server delivering high performance computing large storage capacity and low power consumption It is easy to deploy and manage an...

Страница 9: ...rocessor core to run up to two threads improving parallel computation capability The hardware assisted Intel Virtualization Technology Intel VT allows operating system OS vendors to better use hardwar...

Страница 10: ...to protect the RAID cache data against power failures The server provides simplified O M and efficient troubleshooting through the UID HLY LED indicators on the front panel fault diagnosis LED touch L...

Страница 11: ...ings provide 94 power efficiency at 50 load Efficient voltage regulator down VRD power supplies for boards minimize the energy loss from DC DC power conversion Area based Proportional Integral Derivat...

Страница 12: ...kplane 5 Cable organizer 6 Chassis 7 Air duct 8 Drive Backplane 9 Fan module bracket 10 Drive 11 DVD drive or LCD 12 Fan module 13 VGA board 14 Processor 15 Mainboard 16 TPM TCM 17 Memory 18 Heat sink...

Страница 13: ...up to 32 memory modules The CPUs processors interconnect with each other through three UPI links at a speed of up to 10 4 GT s The server provides nine standard PCIe 3 0 slots of various specification...

Страница 14: ...3 0 ports and serial ports RJ45 The server provides four LOM ports including two 10GE optical ports and two GE electrical ports FusionServer 2488 V5 Server Technical White Paper 4 Logical Structure Is...

Страница 15: ...twork 5 7 I O Expansion 5 8 PSUs 5 9 Fans 5 10 LCD 5 11 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 SAS SATA drive configuration Figure 5 1 Front view FusionServer 2488 V5 Server Technical White P...

Страница 16: ...label 25 x 2 5 SAS SATA drive configuration Figure 5 3 Front view 1 Drives 2 Slide out label plate with an SN label 5 1 2 Indicators and Buttons Indicator and Button Positions 8 x 2 5 SAS SATA drive c...

Страница 17: ...and buttons on the front panel 1 Connection status indicator for 10GE LOM port 1 2 Connection status indicator for 10GE LOM port 2 3 Connection status indicator for GE LOM port 1 4 Connection status i...

Страница 18: ...7 UID button indicator 8 Power button indicator Indicator and Button Descriptions Table 5 1 Description of indicators and buttons on the front panel Sign Indicator and Button Description Fault diagnos...

Страница 19: ...can press this button to power on the device UID button indicator The UID button indicator helps identify and locate a device UID indicator Off The device is not being located Blinking or steady blue...

Страница 20: ...s indicator Each indicator shows the connection status of an Ethernet LOM port Off The network port is not in use or has failed Steady green The network port is properly connected NOTE The indicators...

Страница 21: ...ts on the front panel 1 USB 2 0 ports Port Description Table 5 2 Ports on the front panel Port Type QuantityNote Description VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM...

Страница 22: ...ber of ports varies depending on server configuration This table lists the maximum number of ports in different configurations 5 2 Rear Panel 5 2 1 Appearance Figure 5 10 Rear view 1 PCIe slot 1 2 PCI...

Страница 23: ...indicator of the management network port 4 Health status indicator 5 UID Indicator 6 PSU indicator Indicator Description Table 5 3 Description of indicators on the rear panel Indicator Description LO...

Страница 24: ...The device is not being located Blinking or steady blue The device is being located NOTE You can turn on or off the UID indicator by pressing the UID button or remotely running a command on the iBMC...

Страница 25: ...ports on the rear panel Tool Type Quantity Description LOM port 10GE SFP and 1000BASE T 4 10GE LOM service port optical and GE service port electrical For details see 5 6 1 LOMs VGA port DB15 1 Used t...

Страница 26: ...n abnormal USB device is connected PSU socket 2 Used to connect to the power distribution unit PDU in the cabinet You can select the number of power supply units PSUs as required NOTE When determining...

Страница 27: ...dentifier You can determine the memory module properties based on the label attached to the memory module Figure 5 14 Memory identifier FusionServer 2488 V5 Server Technical White Paper 5 Hardware Des...

Страница 28: ...y P 15 T 17 7 DIMM type R RDIMM L LRDIMM 5 4 1 2 Memory Subsystem Architecture The 2488 V5 provides 32 memory slots Each processor integrates six memory channels Install the memory modules in the prim...

Страница 29: ...MM140 E F DIMM150 F CPU 3 A primary DIMM200 A A DIMM201 G B DIMM210 B C DIMM220 C D primary DIMM230 D D DIMM231 H E DIMM240 E F DIMM250 F CPU 4 A primary DIMM300 A A DIMM301 G B DIMM310 B C DIMM320 C...

Страница 30: ...processors L processors 4 5 TB socket M processors 2 TB socket Other processors 1 TB socket The total memory capacity is the sum of the capacity of all DDR4 DIMMs NOTICE The total memory capacity can...

Страница 31: ...he maximum operating speed of a DIMM can reach 2933 MT s If the Skylake processor is used the maximum operating speed of a DIMM can reach 2666 MT s only Different CPUs possess different specifications...

Страница 32: ...a multi processor configuration each processor must have a valid memory mirroring configuration Memory scrubbing mode Comply with the general installation guidelines 5 4 1 5 Memory Installation Positi...

Страница 33: ...Figure 5 15 Memory slots FusionServer 2488 V5 Server Technical White Paper 5 Hardware Description Issue 06 2023 12 12 Copyright xFusion Digital Technologies Co Ltd 26...

Страница 34: ...elines 4 processors 5 4 1 6 Memory Protection Technologies The following memory protection technologies are supported ECC Full mirroring Address range mirroring FusionServer 2488 V5 Server Technical W...

Страница 35: ...2 5 16 x SAS SATA 8 x NVMe drive configuration Front drives 24 x 2 5 Slots 0 to 3 and slots 20 to 23 support only NVMe drives Slots 4 to 19 support only SAS SATA drives 1 x RAID controller card 2 x NV...

Страница 36: ...uration Figure 5 19 Drive numbering 25 x 2 5 drive configuration 25 x SAS SATA Figure 5 20 Drive numbering 5 5 3 Drive Indicators SAS SATA Drive Indicators Figure 5 21 SAS SATA drive indicators Fusion...

Страница 37: ...ed Steady on Steady on The drive is faulty NVMe Drive Indicators Figure 5 22 NVMe drive indicators If the VMD function is enabled and the latest VMD driver is installed the NVMe drives support surpris...

Страница 38: ...rive Off Blinking at 2 Hz The NVMe drive is being located or hot swapped Off Blinking at 0 5 Hz The hot removal process is complete and the NVMe drive is removable Steady on Off Steady on The NVMe dri...

Страница 39: ...e components to be used For details about the RAID controller card see V5 Server RAID Controller Card User Guide 5 6 Network 5 6 1 LOMs LOMs provide network expansion capabilities Table 5 12 LOM descr...

Страница 40: ...ng a LOM port to a PoE device may cause link communication failure or even damage the NIC The electrical LOM ports GE electrical ports do not support SR IOV Forcibly powering off a server will cause i...

Страница 41: ...ptical port 4 6 Data transmission rate indicator for 10GE optical port 3 Indicator Description Table 5 13 LOM indicators Indicator Description Connection status indicator Data transmission status indi...

Страница 42: ...d to power over Ethernet PoE devices such as a switch with PoE enabled Connecting such an electrical port to a PoE device may cause link communication failure or even damage the NIC Contact your local...

Страница 43: ...3 0 x16 x16 Port2A 0xE2 0 0 HHHL Slot 2 CPU 1 PCIe 3 0 x8 x8 Port1A 0x8 0 0 HHHL Slot 3 CPU 1 PCIe 3 0 x8 x8 Port1C 0x8 2 0 HHHL Slot 4 CPU 2 PCIe 3 0 x16 x16 Port2A 0x62 0 0 FHHL Slot 5 CPU 3 PCIe 3...

Страница 44: ...ts model 5 8 PSUs The server supports one or two PSUs The server supports AC or DC PSUs The PSUs are hot swappable The server supports two PSUs in 1 1 redundancy The same model of PSUs must be used in...

Страница 45: ...e LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management network port on the server The LCD and the server iBMC for...

Страница 46: ...PU temperature and inlet temperature of the server Info Displays the IP address and MAC address of the iBMC management network port MAC addresses of host LOM ports device SNs asset information and fir...

Страница 47: ...uide 5 10 1 LCD Software Environment 5 11 Boards 5 11 1 Mainboard Figure 5 31 2488 V5 mainboard 1 UID Indicator 2 Health status indicator FusionServer 2488 V5 Server Technical White Paper 5 Hardware D...

Страница 48: ...19 Right mounting ear connector J131 20 SATA DVD drive connector J189 21 PCIe x16 slot 7 corresponding to CPU 1 22 LCD connector LCD CONN J87 23 VGA connector J185 24 Fan port 4 FAN4 J102 25 Fan port...

Страница 49: ...ectly c The port is reserved 5 11 2 Drive Backplane 8 x 2 5 drive pass through backplane 8 x SAS SATA Figure 5 32 8 x 2 5 drive pass through backplane 8 x SAS SATA 1 Signal cable connector J1 2 DVD dr...

Страница 50: ...r connector J3 11 NVMe PORT A_N3 J23 12 NVMe PORT B_N3 J27 25 x 2 5 drive EXP backplane 25 x SAS SATA Figure 5 34 25 x 2 5 drive EXP backplane 25 x SAS SATA 1 SAS cable connector PORT A J28 2 SAS cabl...

Страница 51: ...2488 V5 PSU backplane 1 Power connector J303 2 Power connector J304 3 Signal connector J306 FusionServer 2488 V5 Server Technical White Paper 5 Hardware Description Issue 06 2023 12 12 Copyright xFusi...

Страница 52: ...ilt in memory controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Three UPI buses between processors providing up to 10 4GT s transmission per ch...

Страница 53: ...odules of different types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together NOTE The preceding information is for reference only Use the Compatibility Chec...

Страница 54: ...https kb vmware com s article 1033696 Configure syslog For details see https kb vmware com s article 2003322 The M 2 SSD cannot be used to store data due to poor endurance In write intensive applicati...

Страница 55: ...electrical port to a PoE device may cause link communication failure or even damage the NIC I O expansion 9 PCIe 3 0 slots Three slots for built in cards and six for external cards For details see 5...

Страница 56: ...n the mainboard The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors NOTE SM750 is not supported by servers running the Windows Server 2019 or Windows Server 2019 Hyper V operating...

Страница 57: ...mperature within one year 10 C to 35 C 14 F to 95 F Maximum rate of temperature change 20 C 36 F per hour 5 C 9 F per 15 minutes NOTE The highest operating temperature varies depending on the server c...

Страница 58: ...300 month meeting level G1 requirements of the ANSI ISA 71 04 2013 standard on gaseous corrosion Silver corrosion rate test 200 month Particle contaminant The equipment room environment meets the requ...

Страница 59: ...ata stored Maximum preservation duration of HDDs 6 months in unpacked packed and powered off state The maximum preservation duration is determined according to the preservation specifications provided...

Страница 60: ...ars Ball bearing rail kit applies to cabinets with a distance of 610 mm to 914 mm 24 02 in to 35 98 in between the front and rear mounting bars Fully equipped weight Net weight Maximum weight for serv...

Страница 61: ...y cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact sales personnel to...

Страница 62: ...o perform special tasks such as performing high voltage operations and driving a forklift WARNING If this device works in a residential environment the wireless interference may be generated Human Saf...

Страница 63: ...remove any conductive objects such as watches and jewelry Figure 8 2 shows conductive objects that must be removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows ho...

Страница 64: ...not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a device hold the bottom of the d...

Страница 65: ...the maximum weight one person is permitted to carry Table 8 1 lists the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per...

Страница 66: ...edirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Specifications Description Management interface Integrat...

Страница 67: ...litate fault diagnosis Screen snapshots and videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable...

Страница 68: ...019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 3 2013 A1 2019 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 RoH...

Страница 69: ...A1 2015 CISPR 24 2010 A1 2015 ETSI EN 300 386 V1 6 1 2012 ETSI EN 300 386 V2 1 1 2016 RoHS BS EN IEC 63000 2018 ErP Commission Regulation EU 424 2019 China CCC GB 17625 1 2022 GB 4943 1 2022 GB T 925...

Страница 70: ...ct recycling service provided by xFusion after products are scrapped contact technical support for services FusionServer 2488 V5 Server Technical White Paper 11 Waste Product Recycling Issue 06 2023 1...

Страница 71: ...tails see the actual product A 1 1 On the Front Top Figure A 1 Chassis head label 1 Nameplate 2 Certificate 3 Quick access tag 4 SN NOTE For details see A 2 Product SN FusionServer 2488 V5 Server Tech...

Страница 72: ...tes that do not place any objects on top of a rack mounted device A 1 1 1 Nameplate Figure A 2 Nameplate example Table A 1 Nameplate description No Description 1 Server Model For details see A 4 Namep...

Страница 73: ...rcode Figure A 4 Sample certificate No Table A 3 Certificate No Description No Description 1 The value for this digit is P which is fixed 2 The value for this digit is Z which is fixed 3 Y indicates a...

Страница 74: ...Indicates the hour one digit Digits 0 to 9 indicate 0 00 to 9 00 Letters A to H indicate 10 00 to 17 00 Letters J to N indicate 18 00 to 22 00 Letters P to Q indicate 23 00 to 24 00 9 Indicates the s...

Страница 75: ...to obtain technical support resources A 1 2 Chassis Tail Label Figure A 6 Chassis tail label NOTE For details about the warning label see Server Safety Information A 1 3 Chassis Internal Label Figure...

Страница 76: ...e slide out label plate uniquely identifies a device The SN is required when you contact technical support Figure A 8 and Figure A 9 show the SN formats SN example 1 Figure A 8 SN example 1 SN example...

Страница 77: ...ecember respectively 5 Serial number six digits 6 RoHS compliance one character Y indicates RoHS compliant 7 Internal model product name of the board The model format varies according to the actual si...

Страница 78: ...All options supported P4 T4 GPU cards are not supported Options supported processors of up to 165 W Options not supported NVMe SSD cards in slots 1 to 6 GPU cards Not supported NOTE If a single fan i...

Страница 79: ...s Parity Protection Detects memory command and address errors Memory Demand and Patrol Scrubbing Corrects correctable errors upon detection If these errors are not corrected in a timely manner uncorre...

Страница 80: ...oving system availability Error Injection Support Implements fault injection to verify RAS features Machine Check Architecture MCA Provides a software repair function to rectify uncorrectable errors t...

Страница 81: ...TS CPU DTS value CpuN Margin CPU1 Margin temperature CPUN Prochot CPU Prochot CPUN VDDQ Temp CPU VDDQ temperature CPU 1 Components in positions U4333 and U4339 on the mainboard CPU 2 Components in pos...

Страница 82: ...peed sensor Fan module N indicates the fan module ID The value ranges from 1 to 4 FANN R Speed Power Server input power Total PSU power PowerN PSU input power PSU N indicates the PSU number The value...

Страница 83: ...ip fault diagnosis health status Component in position U4014 on the mainboard LCD Presence LCD presence LCD LCD Status LCD health status PSN Redundancy Redundancy failure due to PSU removal PSU N indi...

Страница 84: ...oard 12 0 V voltage the third output 12 V voltage detection for soft start CPU4 fan module SYS 12V_4 Mainboard 12 0 V voltage the fourth output 12 V output voltage detection for soft start drive backp...

Страница 85: ...Watchdog Mngmnt Health Management subsystem health status Riser1 Card Entity presence PCIe RAIDN Temp LSI SAS3508 RAID controller card temperature PCIe RAIDN Temp Avago SAS3004 RAID controller card te...

Страница 86: ...ault diagnosis health status System Notice Hot restart notice Collect error information for the fault diagnosis program System Error System suspension or restart Check the background logs FusionServer...

Страница 87: ...and allows data transfer over various cables at 10 Mbit s The Ethernet specification is the basis for the IEEE 802 3 standard B 2 F J G Gigabit Ethernet GE An extension and enhancement of traditional...

Страница 88: ...n be transformed to a PCIe one by modifying the physical layer instead of software PCIe delivers a faster speed and can replace almost all AGP and PCI buses R redundancy A mechanism that allows a back...

Страница 89: ...97 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor interconnect developed by Intel FusionServer 2488 V5 Server Technical White Paper...

Страница 90: ...tocol AVX Advanced Vector Extensions B BBU backup battery unit BIOS Basic Input Output System C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface FusionS...

Страница 91: ...g and correcting ECMA European Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB D...

Страница 92: ...Control Message Protocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input o...

Страница 93: ...ent controller N NBD next business day NC SI Network Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power m...

Страница 94: ...Computer System Interface SATA Serial Advanced Technology Attachment SCM supply chain management SDDC single device data correction SERDES serializer deserializer SGMII serial gigabit media independe...

Страница 95: ...trusted platform module C 5 U Z U UDIMM unbuffered dual in line memory module UEFI Unified Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Ser...

Страница 96: ...electrical and electronic equipment WSMAN Web Service Management FusionServer 2488 V5 Server Technical White Paper C Acronyms and Abbreviations Issue 06 2023 12 12 Copyright xFusion Digital Technologi...

Отзывы: