Indicator
Description
PSU indicator
● Off: No power is supplied.
● Blinking green at 1 Hz:
– The input is normal, and the server is standby.
– The input is overvoltage or undervoltage.
– The PSU is in deep hibernation mode.
● Blinking green at 4 Hz: The firmware is being
upgraded online.
● Steady green: The power input and output are normal.
● Steady orange: The input is normal, but no power
output is supplied.
NOTE
The possible causes of no power output are as follows:
● Power supply overtemperature protection
● Power output overcurrent or short-circuit
● Output overvoltage
● Short-circuit protection
● Device failure (excluding failure of all devices)
UID Indicator
The UID indicator helps identify and locate a device.
● Off: The device is not being located.
● Blinking or steady blue: The device is being located.
NOTE
You can turn on or off the UID indicator by pressing the UID
button or remotely running a command on the iBMC CLI.
Health status indicator
● Off: The device is powered off or is faulty.
● Blinking red at 1 Hz: A major alarm has been
generated on the system.
● Blinking red at 5 Hz: A critical alarm has been
generated on the system.
● Steady green: The device is operating properly.
Connection status
indicator of the
management network
port
● Off: The network port is not connected.
● Steady green: The network port is properly connected.
Data transmission
status indicator of the
management network
port
● Off: No data is being transmitted.
● Blinking yellow: Data is being transmitted.