![xFusion Digital Technologies FusionServer 1288H V6 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-1288h-v6/fusionserver-1288h-v6_manual_3317099055.webp)
Table 5-22
NVMe drive indicators (VMD enabled)
Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive is not detected.
Steady on
Off
The NVMe drive is detected and
operating properly.
Blinking at 2 Hz
Off
Data is being read from or written to
the NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located.
Off
Blinking at 8 Hz
The data on the secondary NVMe
drive is being rebuilt.
Steady on/Off
Steady on
The NVMe drive is faulty.
●
If the VMD function is disabled, NVMe drives support only orderly hot swap.
Table 5-23
NVMe drive indicators (VMD disabled)
Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive is not detected.
Steady on
Off
The NVMe drive is detected and
operating properly.
Blinking at 2 Hz
Off
Data is being read from or written to
the NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5 Hz
The NVMe drive has completed the
hot swap process and is removable.
Steady on/Off
Steady on
The NVMe drive is faulty.
M.2 FRU Indicators
The server supports the Avago SAS3004iMR RAID controller card, which supports
two M.2 FRUs.
FusionServer 1288H V6 Server
Technical White Paper
5 Hardware Description
Issue 10 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
48