Xetawave XETA4-TMFA Скачать руководство пользователя страница 6

 

 

462.7375 – 467.5375 MHz 
467.7375 – 470 MHz 

FCC Antenna Compliance 

Since professional installation is required, standard RF connectors are used.  Adapters or 

custom coaxial cables may be required to connect the radio’s RF connector to the 

desired antenna. 

Any antenna from a reputable manufacturer with desired bandwidth, gain/pattern 

coverage, and a rated nominal impedance of 50 ohms, can be used. 

FCC Exposure Compliance 

 

FCC ID:  

PEJ-938240 

It is the responsibility of the licensee or user to guarantee compliance with the 

appropriate MPE regulations when operating this device in a way other than described 

herein.  The installer of this equipment must ensure the antenna is located or oriented 

such that it does not emit an RF field in excess of the guidelines in FCC OET Bulletin 65 

and 47CFR § 1.1310. 

People should not be near the antenna when the radio link is operating as general 

practice and maintain a safe distance as calculated below.  

The MPED (Maximum Permissible Exposure Distance) is calculated using the FCC limit 

for a general population/uncontrolled exposure in the 450 - 470 MHz frequency band.  

To calculate safe distance

:

 

(

)(

)(

)

(

)(

)

mit

ExposureLi

n

AntennaGai

DutyCycle

ower

ConductedP

MPED

π

4

=

  

Where:   

MPED

 is Maximum Permissible Exposure Distance or safe distance in cm; 

ConductedPower

 is the power delivered to the antenna in mW; 

ExposureLimit

 is the limit for General Population/ Uncontrolled exposure in mW/cm

2

 

All quantities are calculated in linear or numeric quantities. 

The XETA4-TMFA transmitter duty cycle varies depending on many factors.  Packet sizes, 

which are set up by the installer as part of the radio/network configuration, are a 

primary determinant.  At power up and with no data payload, the radios will transmit a 

beacon with a duty cycle of 6 to 10%, depending upon modulation setting.  The duty 

cycle will increase when a data payload is transmitted, but will also be influenced by 

network configuration, network type, number of radios in the network, propagation 

Содержание XETA4-TMFA

Страница 1: ...XETA4 TMFA User Manual Rev B...

Страница 2: ...ntenna Compliance 8 Configuration 8 Password Protection 8 Communicating with the XETA4 TMFA 8 The Diag Port 8 Operating Menu 10 Configuration Utilities Menu 10 Serial Port Configuration 11 Baud Rate 1...

Страница 3: ...policy may not apply 1 If product repair adjustments or parts replacements is required due to accident neglect or unusual physical electrical or electromagnetic stress 2 If product is used outside of...

Страница 4: ...ed in compliance with FCC regulations in the 450 470 MHz frequency bands The transmit antenna shall be kept at least 187 cm from physical space where humans may exist based on a maximum antenna gain o...

Страница 5: ...member of the public in the direction of maximum radiation Professional installers receive radios with factory preset settings in compliance with the values and limits specified in the radio certifica...

Страница 6: ...tice and maintain a safe distance as calculated below The MPED Maximum Permissible Exposure Distance is calculated using the FCC limit for a general population uncontrolled exposure in the 450 470 MHz...

Страница 7: ...ith Industry Canada s license exempt RSSs Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interfe...

Страница 8: ...z 450 470 MHz IC Setting This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to IC ICES 003 This unit must be installed in a fixed location Cet qui...

Страница 9: ...n science et d veloppement conomique Canada Calcul MPE Use General Utilisation G n ralit s Antenna 11 2 dBi Antenne 11 2 dBi For 406 1 470 MHz single transmitters General use Pour metteurs simples 406...

Страница 10: ...unique mathematical calculation that is proprietary to XetaWave LLC Users have the ability to set parameters via the Diag port within the permissible limits Users do not have access to programming cap...

Страница 11: ...ting interrupt_init coresight_init coresight_start watchdog_init spi_init SPI_BUS_0 spi_init SPI_BUS_1 spi_init SPI_BUS_FLASH flash_init config_init mfg_cals_init math_init twi_init iox_init pll_init...

Страница 12: ...es of the two radios making the link In the above example the radio is a Slave unit address 8 and will link with a Master unit address 1 Options Enter 0 to display the configuration settings and utili...

Страница 13: ...rt configuration menu The standard diagnostics port configuration is 115 2 Kbps 8 data bits no parity 1 stop bit and cannot be changed by the user The data port configuration is editable through Confi...

Страница 14: ...operation Enter 3 to modify the baud clock output that is synchronous with the data serial port The output clock may be used to synchronize the user hardware to the radio clock for ease of serial por...

Страница 15: ...second character represents parity and can be set to N O or E for none odd or even The last character represents stop bits and can be set to 1 1 5 or 2 RF Configuration This menu allows for the select...

Страница 16: ...illiwatts of the radio within the limits of the radio certification This parameter sets the power as measured at the radio connector and does not compensate for any interconnecting cable loss antenna...

Страница 17: ...ve messages from the slave s If the radio is a slave then this is the frequency that it will use to transmit all messages to the master If a three digit number with or without a decimal point and addi...